Sanjeev D Nandedkar

Summary

Publications

  1. ncbi request reprint Some observations on fibrillations and positive sharp waves
    S D Nandedkar
    Oxford Instruments Medical Systems, Hawthorne, New York 10532, USA
    Muscle Nerve 23:888-94. 2000
  2. ncbi request reprint Models and simulations in electromyography
    Sanjeev D Nandedkar
    Oxford Instruments Medical Systems, 12 Skyline Drive, Hawthorne, New York 10532, USA
    Muscle Nerve Suppl 11:S46-54. 2002
  3. ncbi request reprint Motor unit number index (MUNIX)
    Sanjeev D Nandedkar
    Oxford Instruments, 12 Skyline Drive, Hawthorne, NY 10532, USA
    IEEE Trans Biomed Eng 51:2209-11. 2004
  4. ncbi request reprint "Slow" myotonic discharges
    Paul E Barkhaus
    Muscle Nerve 34:799-800. 2006
  5. ncbi request reprint Contribution of reference electrode to the compound muscle action potential
    Sanjeev D Nandedkar
    Viasys Health Care, 5225 Verona Drive, Madison, Wisconsin 52217, USA
    Muscle Nerve 36:87-92. 2007

Detail Information

Publications5

  1. ncbi request reprint Some observations on fibrillations and positive sharp waves
    S D Nandedkar
    Oxford Instruments Medical Systems, Hawthorne, New York 10532, USA
    Muscle Nerve 23:888-94. 2000
    ..The etiology of the waveform characteristics of FP and PSW is discussed based on abnormal propagation in a small section of muscle fiber that is "damaged" by the needle. The results of simple computer simulations are described...
  2. ncbi request reprint Models and simulations in electromyography
    Sanjeev D Nandedkar
    Oxford Instruments Medical Systems, 12 Skyline Drive, Hawthorne, New York 10532, USA
    Muscle Nerve Suppl 11:S46-54. 2002
    ..Combining models with experimental methods will allow us to define new measurements and new rules of interpretation. This is discussed with some of the models developed for electromyography signal analysis...
  3. ncbi request reprint Motor unit number index (MUNIX)
    Sanjeev D Nandedkar
    Oxford Instruments, 12 Skyline Drive, Hawthorne, NY 10532, USA
    IEEE Trans Biomed Eng 51:2209-11. 2004
    ..Lower MUNIX values were seen in weaker muscles. This is a noninvasive method that requires minimal electrical stimulation. It is performed in less than 5 min. This makes it suitable for serial EMG investigations...
  4. ncbi request reprint "Slow" myotonic discharges
    Paul E Barkhaus
    Muscle Nerve 34:799-800. 2006
  5. ncbi request reprint Contribution of reference electrode to the compound muscle action potential
    Sanjeev D Nandedkar
    Viasys Health Care, 5225 Verona Drive, Madison, Wisconsin 52217, USA
    Muscle Nerve 36:87-92. 2007
    ....