Sanjeev D Nandedkar

Summary

Publications

  1. doi Motor unit number index (MUNIX): principle, method, and findings in healthy subjects and in patients with motor neuron disease
    Sanjeev D Nandedkar
    CareFusion, Middleton, Wisconsin, USA
    Muscle Nerve 42:798-807. 2010
  2. doi Reproducibility of MUNIX in patients with amyotrophic lateral sclerosis
    Sanjeev D Nandedkar
    CareFusion, Middleton, Wisconsin, USA
    Muscle Nerve 44:919-22. 2011
  3. doi Deep brain stimulator artifact in needle electromyography: effects and distribution in paraspinal and upper limb muscle
    Sanjeev D Nandedkar
    CareFusion, Middleton, Wisconsin, USA
    Muscle Nerve 47:561-5. 2013
  4. doi Emerging techniques in the electrodiagnostic laboratory
    Sanjeev D Nandedkar
    Natus Medical Inc, 1850 Demming Way, Middleton, WI 53560, USA
    PM R 5:S115-22. 2013

Collaborators

Detail Information

Publications4

  1. doi Motor unit number index (MUNIX): principle, method, and findings in healthy subjects and in patients with motor neuron disease
    Sanjeev D Nandedkar
    CareFusion, Middleton, Wisconsin, USA
    Muscle Nerve 42:798-807. 2010
    ..When the CMAP changed significantly (>30%) in 1 year, the CMAP and MUNIX decreased in parallel. MUNIX would be useful to study MU loss in degenerative diseases of motor neurons. Muscle Nerve 42: 798-807, 2010...
  2. doi Reproducibility of MUNIX in patients with amyotrophic lateral sclerosis
    Sanjeev D Nandedkar
    CareFusion, Middleton, Wisconsin, USA
    Muscle Nerve 44:919-22. 2011
    ..In this study we investigated the reproducibility of motor unit number index (MUNIX) in patients with amyotrophic lateral sclerosis (ALS)...
  3. doi Deep brain stimulator artifact in needle electromyography: effects and distribution in paraspinal and upper limb muscle
    Sanjeev D Nandedkar
    CareFusion, Middleton, Wisconsin, USA
    Muscle Nerve 47:561-5. 2013
    ..Deep brain stimulators (DBS) have become a more widespread treatment option for individuals with centrally mediated movement disorders. Such devices are expected to create artifact in standard needle electromyographic (EMG) recordings...
  4. doi Emerging techniques in the electrodiagnostic laboratory
    Sanjeev D Nandedkar
    Natus Medical Inc, 1850 Demming Way, Middleton, WI 53560, USA
    PM R 5:S115-22. 2013
    ..This article will discuss these trends and give examples of a few new and emerging methods that have the potential for use in an electrodiagnostic laboratory...