Research Topics
| Sucbei MoonSummaryAffiliation: Gwangju Institute of Science and Technology Country: Korea Publications
| Collaborators
|
Detail Information
Publications
Analog single-photon counter for high-speed scanning microscopySucbei Moon
Department of Information and Communications, Gwangju Institute of Science and Technology, Buk Gu, Gwangju, Republic of Korea
Opt Express 16:13990-4003. 2008....
Analog mean-delay method for high-speed fluorescence lifetime measurementSucbei Moon
Department of Information and Communications, Gwangju Institute of Science and Technology, Buk Gu, Gwangju, Republic of Korea 500 712
Opt Express 17:2834-49. 2009..A fluorescence lifetime of 3.2 ns was accurately determined with a standard deviation of 3% from the data acquired within 17.8 micros at a rate of 56,300 lifetime determinations per second...
High-speed confocal fluorescence lifetime imaging microscopy (FLIM) with the analog mean delay (AMD) methodYoungjae Won
Department of Information and Communications, Gwangju Institute of Science and Technology, 1 Oryong dong, Buk Gu, Gwangju 500 712, South Korea
Opt Express 19:3396-405. 2011..We have achieved the photon detection rate of 125 times faster than a conventional TCSPC based system in this experiment...
Site-specific multipoint fluorescence measurement system with end-capped optical fibersWoosub Song
Department of Mechatronics, Gwangju Institute of Science and Technology, 1 Oryong dong, Buk Gu, Gwangju 500 712, South Korea
Appl Opt 50:3529-37. 2011..We expect that the proposed multipoint site-specific fluorescence measurement system can be used as an inexpensive fluorescence measurement tool to study many intracellular and molecular dynamics in cell biology...
Masked illumination scheme for a galvanometer scanning high-speed confocal fluorescence microscopeDong Uk Kim
School of Information and Mechatronics, Gwangju Institute of Science and Technology, Gwangju, Republic of Korea
Scanning 33:455-62. 2011..We have experimentally demonstrated the advantages of our masked illumination method in detail...
High temperature fiber sensor with high sensitivity based on core diameter mismatchLinh Viet Nguyen
Department of Information and Communications, School of Photon Science and Technology, Gwangju Institute of Science and Technology, Buk Gu, Gwangju, Korea
Opt Express 16:11369-75. 2008..The temperature sensor can measure temperature stably up to more than 900 degrees C with sensitivity of 0.088 nm/ degrees C...
Referencing techniques for the analog mean-delay method in fluorescence lifetime imagingYoung Jae Won
Department of Information and Communications, Gwangju Institute of Science and Technology, 1 Oryong dong, Buk Gu, Gwangju 500 712, South Korea
J Opt Soc Am A Opt Image Sci Vis 27:2402-10. 2010..We have shown that this error can be reduced to 9 ps with our electronic referencing technique. It is demonstrated that this can be further reduced to 4 ps by the optical referencing technique we have introduced...
