Katsuhiko Maruo

Summary

Affiliation: Matsushita Electric Works Ltd
Country: Japan

Publications

  1. ncbi request reprint New methodology to obtain a calibration model for noninvasive near-infrared blood glucose monitoring
    Katsuhiko Maruo
    Matsushita Electric Works Ltd, Kadoma, Osaka 571 8686, Japan
    Appl Spectrosc 60:441-9. 2006
  2. ncbi request reprint Noninvasive near-infrared blood glucose monitoring using a calibration model built by a numerical simulation method: Trial application to patients in an intensive care unit
    Katsuhiko Maruo
    Matsushita Electric Works Ltd, Kadoma, Osaka 571 8686, Japan
    Appl Spectrosc 60:1423-31. 2006
  3. ncbi request reprint In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy
    Katsuhiko Maruo
    NBT Project, Matsushita Electric Works Ltd, Kadoma, Osaka 571 8686, Japan
    Appl Spectrosc 57:1236-44. 2003
  4. doi request reprint Preliminary evaluation of optical glucose sensing in red cell concentrations using near-infrared diffuse-reflectance spectroscopy
    Yusuke Suzuki
    Panasonic Electric Works Co, Ltd, Advanced Technologies Development Laboratory, 1048, Kadoma Kadoma city, Osaka 571 8686, Japan
    J Biomed Opt 17:017004. 2012
  5. ncbi request reprint Improvement of the partial least squares model performance for oral glucose intake experiments by inside mean centering and inside multiplicative signal correction
    Yi Ping Du
    College of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China
    Anal Sci 21:979-84. 2005
  6. ncbi request reprint Multi-objective genetic algorithm-based sample selection for partial least squares model building with applications to near-infrared spectroscopic data
    Hideyuki Shinzawa
    Department of Chemistry and Research Center for Near Infrared Spectroscopy, School of Science and Technology, Kwansei Gakuin University, Hyogo 669 1337, Japan
    Appl Spectrosc 60:631-40. 2006
  7. ncbi request reprint Removal of interference signals due to water from in vivo near-infrared (NIR) spectra of blood glucose by region orthogonal signal correction (ROSC)
    Ping Du Yi
    Department of Chemistry, Research Center for Near Infrared Spectroscopy, School of Science and Technology, Kwansei Gakuin University, Sanda 669 1337, Japan
    Anal Sci 20:1339-45. 2004

Collaborators

Detail Information

Publications7

  1. ncbi request reprint New methodology to obtain a calibration model for noninvasive near-infrared blood glucose monitoring
    Katsuhiko Maruo
    Matsushita Electric Works Ltd, Kadoma, Osaka 571 8686, Japan
    Appl Spectrosc 60:441-9. 2006
    ..This new calibration methodology using numerical simulation has promising potential for NIR spectroscopy, especially for noninvasive blood glucose monitoring...
  2. ncbi request reprint Noninvasive near-infrared blood glucose monitoring using a calibration model built by a numerical simulation method: Trial application to patients in an intensive care unit
    Katsuhiko Maruo
    Matsushita Electric Works Ltd, Kadoma, Osaka 571 8686, Japan
    Appl Spectrosc 60:1423-31. 2006
    ....
  3. ncbi request reprint In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy
    Katsuhiko Maruo
    NBT Project, Matsushita Electric Works Ltd, Kadoma, Osaka 571 8686, Japan
    Appl Spectrosc 57:1236-44. 2003
    ..The potential of noninvasive blood glucose monitoring using our methodology was demonstrated by the present study...
  4. doi request reprint Preliminary evaluation of optical glucose sensing in red cell concentrations using near-infrared diffuse-reflectance spectroscopy
    Yusuke Suzuki
    Panasonic Electric Works Co, Ltd, Advanced Technologies Development Laboratory, 1048, Kadoma Kadoma city, Osaka 571 8686, Japan
    J Biomed Opt 17:017004. 2012
    ..The results suggest that the diffuse-reflectance spectroscopy may provide another avenue for the detection of bacterial contamination in red cell concentrations (RCC) products...
  5. ncbi request reprint Improvement of the partial least squares model performance for oral glucose intake experiments by inside mean centering and inside multiplicative signal correction
    Yi Ping Du
    College of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China
    Anal Sci 21:979-84. 2005
    ..This is a potential chemometric technique with simplicity, rapidity and efficiency in the pretreatment of NIR spectra collected during oral glucose intake experiments...
  6. ncbi request reprint Multi-objective genetic algorithm-based sample selection for partial least squares model building with applications to near-infrared spectroscopic data
    Hideyuki Shinzawa
    Department of Chemistry and Research Center for Near Infrared Spectroscopy, School of Science and Technology, Kwansei Gakuin University, Hyogo 669 1337, Japan
    Appl Spectrosc 60:631-40. 2006
    ..They also show that the sample selection by multi-objective GA enhances the ability of the PLS models to detect samples with systematic errors...
  7. ncbi request reprint Removal of interference signals due to water from in vivo near-infrared (NIR) spectra of blood glucose by region orthogonal signal correction (ROSC)
    Ping Du Yi
    Department of Chemistry, Research Center for Near Infrared Spectroscopy, School of Science and Technology, Kwansei Gakuin University, Sanda 669 1337, Japan
    Anal Sci 20:1339-45. 2004
    ..Especially, the later region yields a model with RMSECV of 15.8911 mg/dL for four PLS components. ROSC is a potential chemometric technique in the pretreatment of various spectra...