Yoshito Inoue

Summary

Country: Japan

Publications

  1. doi request reprint Novel beating heart repair for anomalous origin of right coronary artery
    Yoshito Inoue
    Department of Cardiovascular Surgery, Hiratsuka City Hospital, Kanagawa, Japan Electronic address
    Ann Thorac Surg 96:e141-3. 2013
  2. doi request reprint Modified intraatrial translocation for prosthetic mitral valve endocarditis
    Yoshito Inoue
    Department of Cardiovascular Surgery, Hiratsuka City Hospital, Kanagawa, Japan
    Ann Thorac Surg 96:305-7. 2013
  3. doi request reprint Synchronized epiaortic two-dimensional and color Doppler echocardiographic guidance enables routine ascending aortic cannulation in type A acute aortic dissection
    Yoshito Inoue
    Department of Cardiovascular Surgery, Hiratsuka, City Hospital, Kanagawa, Japan
    J Thorac Cardiovasc Surg 141:354-60. 2011
  4. doi request reprint Echo-endoscope biplane navigation system for endovascular aneurysm repair
    Yoshito Inoue
    Department of Cardiovascular Surgery, Hiratsuka City Hospital, Hiratsuka, Kanagawa 254 0065, Japan
    Ann Thorac Surg 90:622-6. 2010
  5. ncbi request reprint Ascending aorta cannulation in acute type A aortic dissection
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, 911 1 Takebayashi, Utsunomiya, Tochigi 321 0974, Japan
    Eur J Cardiothorac Surg 31:976-9; discussion 979-81. 2007
  6. doi request reprint Risk factor analysis for acute type A aortic dissection after aortic valve replacement
    Koji Tsutsumi
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, 911 1 Takebayashi machi, Utsunomiya, Tochigi, 321 0974, Japan
    Gen Thorac Cardiovasc Surg 58:601-5. 2010
  7. ncbi request reprint Teflon felt wrapping repair for coronary perforation after failed angioplasty
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Tochigi, Japan
    Ann Thorac Surg 82:2312-4. 2006
  8. doi request reprint Mediastinal hematoma: another lethal sign of aortic dissection
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Utsunomiya, Tochigi, Japan
    Interact Cardiovasc Thorac Surg 8:275-6. 2009
  9. ncbi request reprint Traumatic aortic regurgitation caused by a detached commissure
    Shinichi Taguchi
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, 911 1 Takebayashi machi, Utsunomiya, Tochigi 321 0974, Japan
    Gen Thorac Cardiovasc Surg 55:32-4. 2007
  10. ncbi request reprint Beating-heart epicardial radiofrequency ablation: optimal temperature setting
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Utsunomiya, Tochigi, Japan
    Ann Thorac Surg 78:308-11; discussion 312. 2004

Collaborators

Detail Information

Publications18

  1. doi request reprint Novel beating heart repair for anomalous origin of right coronary artery
    Yoshito Inoue
    Department of Cardiovascular Surgery, Hiratsuka City Hospital, Kanagawa, Japan Electronic address
    Ann Thorac Surg 96:e141-3. 2013
    ..It does not require aortic cross-clamping, cardioplegic arrest, aortotomy, or manipulation of the aortic commissure. Beating heart repair is a simple and effective procedure, which adds an ideal treatment option for ARCA. ..
  2. doi request reprint Modified intraatrial translocation for prosthetic mitral valve endocarditis
    Yoshito Inoue
    Department of Cardiovascular Surgery, Hiratsuka City Hospital, Kanagawa, Japan
    Ann Thorac Surg 96:305-7. 2013
    ..We describe a surgical procedure of modified intraatrial translocation combined with sewing ring shielding, aimed at preventing the recurrence of severe methicillin-resistant staphylococci PVE in the mitral position. ..
  3. doi request reprint Synchronized epiaortic two-dimensional and color Doppler echocardiographic guidance enables routine ascending aortic cannulation in type A acute aortic dissection
    Yoshito Inoue
    Department of Cardiovascular Surgery, Hiratsuka, City Hospital, Kanagawa, Japan
    J Thorac Cardiovasc Surg 141:354-60. 2011
    ..It has not been used routinely, however, because of the disruption caused to the aorta. We evaluated the safety and efficacy of routine cannulation of the dissected aorta for the repair of type A dissection...
  4. doi request reprint Echo-endoscope biplane navigation system for endovascular aneurysm repair
    Yoshito Inoue
    Department of Cardiovascular Surgery, Hiratsuka City Hospital, Hiratsuka, Kanagawa 254 0065, Japan
    Ann Thorac Surg 90:622-6. 2010
    ..We evaluated the feasibility of a bimodal monitoring system consisting of echocardiography and endoscopy as a more accurate anatomical navigation system for endovascular intervention...
  5. ncbi request reprint Ascending aorta cannulation in acute type A aortic dissection
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, 911 1 Takebayashi, Utsunomiya, Tochigi 321 0974, Japan
    Eur J Cardiothorac Surg 31:976-9; discussion 979-81. 2007
    ..Thus, we evaluated the efficacy of use of the dissected ascending aorta as an alternative arterial inflow...
  6. doi request reprint Risk factor analysis for acute type A aortic dissection after aortic valve replacement
    Koji Tsutsumi
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, 911 1 Takebayashi machi, Utsunomiya, Tochigi, 321 0974, Japan
    Gen Thorac Cardiovasc Surg 58:601-5. 2010
    ..Previous aortic valve replacement (AVR) is considered to be an independent risk factor for late acute type A aortic dissection (AAAD). However, the predictors of late AAAD at the time of AVR have not been characterized...
  7. ncbi request reprint Teflon felt wrapping repair for coronary perforation after failed angioplasty
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Tochigi, Japan
    Ann Thorac Surg 82:2312-4. 2006
    ..This procedure was successfully performed with type III perforation of the left anterior descending coronary artery on 2 patients subjected to multiple stenting...
  8. doi request reprint Mediastinal hematoma: another lethal sign of aortic dissection
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Utsunomiya, Tochigi, Japan
    Interact Cardiovasc Thorac Surg 8:275-6. 2009
    ..Mediastinal hematoma combined with simultaneous obstruction of pulmonary artery and superior vena cava is a rare entity and should be recognized as one of the acutely fatal signs of type A dissection...
  9. ncbi request reprint Traumatic aortic regurgitation caused by a detached commissure
    Shinichi Taguchi
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, 911 1 Takebayashi machi, Utsunomiya, Tochigi 321 0974, Japan
    Gen Thorac Cardiovasc Surg 55:32-4. 2007
    ..His aortic valve was replaced, and his postoperative course was uneventful...
  10. ncbi request reprint Beating-heart epicardial radiofrequency ablation: optimal temperature setting
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Utsunomiya, Tochigi, Japan
    Ann Thorac Surg 78:308-11; discussion 312. 2004
    ..We evaluated the effective temperature for the placement of circular lesions around the pulmonary vein-left atrial junction...
  11. doi request reprint Long-term results and mid-term features of left ventricular reconstruction procedures on left ventricular volume, geometry, function and mitral regurgitation
    Yasunori Cho
    Department of Cardiovascular Surgery, Tokai University School of Medicine, Isehara, Japan
    Eur J Cardiothorac Surg 42:462-9. 2012
    ....
  12. doi request reprint High-frequency ultrasound-guided late surgical revascularisation of chronically occluded left anterior descending coronary artery
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Utsunomiya, Tochigi, Japan
    Eur J Cardiothorac Surg 37:239-41. 2010
    ....
  13. ncbi request reprint Nonaneurysmal rupture 30 years after patch aortoplasty for coarctation
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Utsunomiya, Tochigi, Japan
    J Thorac Cardiovasc Surg 132:1480-1. 2006
  14. doi request reprint Current density distribution by ring and diagonally arranged half-ring electrodes in bipolar and overlapping biphasic impulse stimulation
    Satoru Suzuki
    Department of Cardiovascular Surgery, Hiratsuka City Hospital, Hiratsuka, Kanagawa, Japan
    Pacing Clin Electrophysiol 33:1063-73. 2010
    ..We made two three-dimensional computational analysis models to verify our clinical studies...
  15. doi request reprint The use of intra-aortic balloon pump as cerebral protection in a patient with moyamoya disease undergoing coronary artery bypass grafting
    Ichiro Kashima
    Department of Cardiovascular Surgery, Saiseikai Utsumomiya Hospital, 911 1, Takebayashi machi, Utsunomiya, Tochigi, 321 0974, Japan
    Interact Cardiovasc Thorac Surg 7:522-3. 2008
    ....
  16. ncbi request reprint Aortic intramural hematoma with severe aortic regurgitation
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Tochigi, Japan
    Jpn J Thorac Cardiovasc Surg 51:198-200. 2003
    ..Few reports of IMH include concomitant aortic regurgitation. Surgery involved aortic root remodeling and prosthetic graft replacement of the ascending aorta...
  17. ncbi request reprint Recurrent discrete subaortic stenosis and small aortic annulus successfully repaired by the Konno procedure in a young woman
    Ichiro Kashima
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Utsunomiya, Tochigi, Japan
    Jpn J Thorac Cardiovasc Surg 54:451-3. 2006
    ..The Konno operation is a good option for recurrent subaortic stenosis with small aortic annulus...
  18. ncbi request reprint Cardioscopic guidance of linear lesion creation for radiofrequency ablation
    Yoshito Inoue
    Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Tochigi, Japan
    Ann Thorac Surg 75:1189-93. 2003
    ..Therefore, we evaluated cardioscopy as a more accurate method of guiding the catheter for the placement of linear lesions...