Research Topics
| Nobuyasu KomasawaSummaryAffiliation: Hyogo College of Medicine Country: Japan Publications
| Collaborators
|
Detail Information
Publications
Comparison of air-Q(®) and Soft Seal(®) laryngeal mask for airway management by novice doctors during infant chest compression: a manikin studyNobuyasu Komasawa
Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
Resuscitation 83:365-8. 2012..We therefore compared the utility of the air-Q(®) LMA (air-Q) with that of the Soft Seal(®) LMA (Soft Seal) for infant CPR in an infant manikin...
Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin studyNobuyasu Komasawa
Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
J Anesth 24:306-8. 2010..Based on these results, we conclude that the use of the AWS may reduce the time needed to secure the airway during chest compression...
Comparison of Pentax-AWS Airwayscope video laryngoscope, Airtraq optic laryngoscope, and Macintosh laryngoscope during cardiopulmonary resuscitation under cervical stabilization: a manikin studyNobuyasu Komasawa
Department of Anesthesiology, Hyogo College of Medicine, 1 1 Mukogawa cho, Nishinomiya, Hyogo, 663 8501, Japan
J Anesth 25:898-903. 2011..We first evaluated ATQ utility during chest compression with or without cervical stabilization and then compared the AWS, ATQ, and Macintosh laryngoscope (McL) during chest compressions under cervical stabilization in a manikin...
Comparison of Laryngeal Mask Supreme® and Soft Seal® for airway management in several positionsNobuyasu Komasawa
Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
J Anesth 25:535-9. 2011....
Comparison of optic laryngoscope Airtraq(®) and Miller laryngoscope for tracheal intubation during infant cardiopulmonary resuscitationNobuyasu Komasawa
Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
Resuscitation 82:736-9. 2011..We compared the utility of the Miller laryngoscope (Mil) with Airtraq (ATQ) during chest compression in an infant manikin...
Evaluation of tracheal intubation in several positions by the Pentax-AWS Airway Scope: a manikin studyNobuyasu Komasawa
Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
J Anesth 24:908-12. 2010..We hypothesized that the Pentax-AWS Airway Scope (AWS) may be useful for emergent tracheal intubation in such positions...
Validation of the Pentax-AWS Airwayscope utility as an intubation device during cardiopulmonary resuscitation on the groundNobuyasu Komasawa
Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
J Anesth 24:582-6. 2010..However, because most cardiopulmonary arrest happens "on the ground" in the real world, we compared the utility of the McL and the AWS during chest compression on the ground and on the bed...
Comparison of Supreme(®) and Soft Seal(®) laryngeal masks for airway management during cardiopulmonary resuscitation in novice doctors: a manikin studyHanako Kohama
Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
J Anesth 25:98-103. 2011..We compared the utility of a newly developed LMA, the Supreme(®) (Supreme), with a conventional LMA, the Soft Seal(®) (Soft Seal)...
Addition of a video camera system improves the ease of Airtraq(®) tracheal intubation during chest compressionHanako Kohama
Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
J Anesth 26:296-8. 2012..05), but not with the ATQ-V (without chest compression, 15.9 ± 5.8 s; with chest compression, 17.3 ± 5.3 s; P > 0.05). The ATQ video camera system improves the ease of tracheal intubation during chest compressions...
Backboard insertion in the operating table increases chest compression depth: a manikin studyHajime Sato
Division of Intensive Care Unit, Hyogo College of Medicine, Hyogo, Japan
J Anesth 25:770-2. 2011..6% ± 32.3%-81.8% ± 15.0%, P < 0.0001). Applying a backboard significantly increased CC depth during cardiopulmonary resuscitation of a manikin model on an operating table with a pressure-distributing mattress...
[Case of awake intubation in semi-sitting position for a patient with myasthenia gravis combined with cervical disc hernia utilizing Pentax-AWS Airwayscope]Nobuyasu Komasawa
Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya 663 8501
Masui 60:84-7. 2011..The patient did not buck during intubation and no hemodynamic change was observed...
[A case of awake intubation using the pentax-AWS airwayscope in a patient with a difficult airway combined with severe hemorrhagic shock]Nobuyasu Komasawa
Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya 663 8501
Masui 62:197-9. 2013..The patient underwent awake intubation with the AWS under dexmedetomidine sedation and lidocaine spray for laryngotracheal anesthesia. The patient did not buck during intubation and hemodynamic changes were minimal...
[Anesthesia for tracheal metal stent management utilizing venovenous extracorporeal life support]Takahiko Kaneko
Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya 663 8501
Masui 61:1269-72. 2012..Oxygenation and carbon dioxide excretion were achieved uneventfully. VV-ECLS was considered useful for the management of subglottic difficult airway such as complex tracheal stenosis...
[Case of tension pneumothorax associated with asthma attack during general anesthesia]Nobuyasu Komasawa
Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya 663 8501
Masui 59:614-7. 2010..She was extubated on postoperative day 1 without any neurological disorder. Hyperinflation of fragile alveoli by mechanical ventilation was likely a cause of tension pneumothorax...