Nobuyasu Komasawa

Summary

Affiliation: Hyogo College of Medicine
Country: Japan

Publications

  1. ncbi Comparison of air-Q(®) and Soft Seal(®) laryngeal mask for airway management by novice doctors during infant chest compression: a manikin study
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    Resuscitation 83:365-8. 2012
  2. ncbi Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin study
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 24:306-8. 2010
  3. ncbi Comparison of Pentax-AWS Airwayscope video laryngoscope, Airtraq optic laryngoscope, and Macintosh laryngoscope during cardiopulmonary resuscitation under cervical stabilization: a manikin study
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, 1 1 Mukogawa cho, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 25:898-903. 2011
  4. ncbi Comparison of Laryngeal Mask Supreme® and Soft Seal® for airway management in several positions
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    J Anesth 25:535-9. 2011
  5. ncbi Comparison of optic laryngoscope Airtraq(®) and Miller laryngoscope for tracheal intubation during infant cardiopulmonary resuscitation
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    Resuscitation 82:736-9. 2011
  6. ncbi Evaluation of tracheal intubation in several positions by the Pentax-AWS Airway Scope: a manikin study
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    J Anesth 24:908-12. 2010
  7. ncbi Validation of the Pentax-AWS Airwayscope utility as an intubation device during cardiopulmonary resuscitation on the ground
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 24:582-6. 2010
  8. ncbi Utility of the Pentax-AWS Airwayscope and Macintosh laryngoscope for airway management during chest compressions in 27° left-lateral tilt: a manikin simulation study of maternal cardiopulmonary resuscitation
    Hanako Kohama
    Division of Intensive Care, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 27:671-5. 2013
  9. ncbi Comparison of Supreme(®) and Soft Seal(®) laryngeal masks for airway management during cardiopulmonary resuscitation in novice doctors: a manikin study
    Hanako Kohama
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    J Anesth 25:98-103. 2011
  10. ncbi Comparison of Pentax-AWS Airwayscope, Airtraq and Miller laryngoscope for tracheal intubation by novice doctors during infant cardiopulmonary resuscitation simulation: a randomized crossover trial
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 27:778-80. 2013

Collaborators

  • Takuro Sanuki
  • Ryusuke Ueki
  • Hanako Kohama
  • Yoshiroh Kaminoh
  • Shin ichi Nishi
  • Motoi Itani
  • Takahiko Kaneko
  • Noriyasu Yamamoto
  • Hajime Sato
  • Takashi Sugi
  • Kenta Nishimoto
  • Munetaka Hirose
  • Chikara Tashiro
  • Tsuneo Tatara
  • Masashi Nakagawa
  • Akari Fujii
  • Aoi Samma

Detail Information

Publications21

  1. ncbi Comparison of air-Q(®) and Soft Seal(®) laryngeal mask for airway management by novice doctors during infant chest compression: a manikin study
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    Resuscitation 83:365-8. 2012
    ..We therefore compared the utility of the air-Q(®) LMA (air-Q) with that of the Soft Seal(®) LMA (Soft Seal) for infant CPR in an infant manikin...
  2. ncbi Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin study
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 24:306-8. 2010
    ..Based on these results, we conclude that the use of the AWS may reduce the time needed to secure the airway during chest compression...
  3. ncbi Comparison of Pentax-AWS Airwayscope video laryngoscope, Airtraq optic laryngoscope, and Macintosh laryngoscope during cardiopulmonary resuscitation under cervical stabilization: a manikin study
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, 1 1 Mukogawa cho, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 25:898-903. 2011
    ..We first evaluated ATQ utility during chest compression with or without cervical stabilization and then compared the AWS, ATQ, and Macintosh laryngoscope (McL) during chest compressions under cervical stabilization in a manikin...
  4. ncbi Comparison of Laryngeal Mask Supreme® and Soft Seal® for airway management in several positions
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    J Anesth 25:535-9. 2011
    ....
  5. ncbi Comparison of optic laryngoscope Airtraq(®) and Miller laryngoscope for tracheal intubation during infant cardiopulmonary resuscitation
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    Resuscitation 82:736-9. 2011
    ..We compared the utility of the Miller laryngoscope (Mil) with Airtraq (ATQ) during chest compression in an infant manikin...
  6. ncbi Evaluation of tracheal intubation in several positions by the Pentax-AWS Airway Scope: a manikin study
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    J Anesth 24:908-12. 2010
    ..We hypothesized that the Pentax-AWS Airway Scope (AWS) may be useful for emergent tracheal intubation in such positions...
  7. ncbi Validation of the Pentax-AWS Airwayscope utility as an intubation device during cardiopulmonary resuscitation on the ground
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 24:582-6. 2010
    ..However, because most cardiopulmonary arrest happens "on the ground" in the real world, we compared the utility of the McL and the AWS during chest compression on the ground and on the bed...
  8. ncbi Utility of the Pentax-AWS Airwayscope and Macintosh laryngoscope for airway management during chest compressions in 27° left-lateral tilt: a manikin simulation study of maternal cardiopulmonary resuscitation
    Hanako Kohama
    Division of Intensive Care, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 27:671-5. 2013
    ..We examined the performance of the Pentax-AWS Airwayscope (AWS) and Macintosh laryngoscope (McL) for airway management during chest compressions on a 27° left-lateral tilt (27 LLT) operating table...
  9. ncbi Comparison of Supreme(®) and Soft Seal(®) laryngeal masks for airway management during cardiopulmonary resuscitation in novice doctors: a manikin study
    Hanako Kohama
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    J Anesth 25:98-103. 2011
    ..We compared the utility of a newly developed LMA, the Supreme(®) (Supreme), with a conventional LMA, the Soft Seal(®) (Soft Seal)...
  10. ncbi Comparison of Pentax-AWS Airwayscope, Airtraq and Miller laryngoscope for tracheal intubation by novice doctors during infant cardiopulmonary resuscitation simulation: a randomized crossover trial
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 27:778-80. 2013
    ..The AWS-I is an effective device for endotracheal intubation during chest compressions in infant simulations managed by novice doctors...
  11. ncbi Addition of a video camera system improves the ease of Airtraq(®) tracheal intubation during chest compression
    Hanako Kohama
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo 663 8501, Japan
    J Anesth 26:296-8. 2012
    ..05), but not with the ATQ-V (without chest compression, 15.9 ± 5.8 s; with chest compression, 17.3 ± 5.3 s; P > 0.05). The ATQ video camera system improves the ease of tracheal intubation during chest compressions...
  12. ncbi Backboard insertion in the operating table increases chest compression depth: a manikin study
    Hajime Sato
    Division of Intensive Care Unit, Hyogo College of Medicine, Hyogo, Japan
    J Anesth 25:770-2. 2011
    ..6% ± 32.3%-81.8% ± 15.0%, P < 0.0001). Applying a backboard significantly increased CC depth during cardiopulmonary resuscitation of a manikin model on an operating table with a pressure-distributing mattress...
  13. ncbi [Application of air-Q laryngeal airway and gum elastic bougie in a case of anticipated difficult. Mask ventilation and tracheal intubation in a man with morbid obesity]
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya 663 8501
    Masui 62:670-3. 2013
    ..5 mm tracheal tube. This case was a successful use of the air-Q under moderate sedation for airway management in the setting of anticipated difficult mask ventilation and tracheal intubation...
  14. ncbi [A case of awake intubation using the Pentax-AWS airwayscope in a patient with a difficult airway combined with severe hemorrhagic shock]
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya 663 8501
    Masui 62:197-9. 2013
    ..The patient underwent awake intubation with the AWS under dexmedetomidine sedation and lidocaine spray for laryngotracheal anesthesia. The patient did not buck during intubation and hemodynamic changes were minimal...
  15. ncbi [Case of awake intubation in semi-sitting position for a patient with myasthenia gravis combined with cervical disc hernia utilizing Pentax-AWS Airwayscope]
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya 663 8501
    Masui 60:84-7. 2011
    ..The patient did not buck during intubation and no hemodynamic change was observed...
  16. ncbi Effects of a simulation-based sedation training course on non-anesthesiologists' attitudes toward sedation and analgesia
    Nobuyasu Komasawa
    Department of Anesthesiology, Osaka Medical College, Daigaku machi 2 7, Takatsukishi, Osaka, 569 8686, Japan
    J Anesth 28:785-9. 2014
    ..As non-anesthesiologists experience several complications during sedation, SEDTC may be useful for the improvement of their attitude toward the safety management of sedation...
  17. ncbi Evaluation of chest compression effect on airway management with air-Q, aura-i, i-gel, and Fastrack intubating supraglottic devices by novice physicians: a randomized crossover simulation study
    Nobuyasu Komasawa
    Department of Anesthesiology, Osaka Medical College, Daigaku machi 2 7, Takatsuki, Osaka, 569 8686, Japan
    J Anesth 28:676-80. 2014
    ....
  18. ncbi [Anesthesia for tracheal metal stent management utilizing venovenous extracorporeal life support]
    Takahiko Kaneko
    Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya 663 8501
    Masui 61:1269-72. 2012
    ..Oxygenation and carbon dioxide excretion were achieved uneventfully. VV-ECLS was considered useful for the management of subglottic difficult airway such as complex tracheal stenosis...
  19. ncbi Comparison of Insertion of the Modified i-gel Airway for Oral Surgery With the LMA Flexible: A Manikin Study
    Takuro Sanuki
    Department of Anesthesiology, Osaka Dental University, Osaka, Japan
    Anesth Prog 61:145-9. 2014
    ..012). When used by an inexperienced operator, the modified i-gelâ„¢ airway is faster and has a higher success rate than the LMA Flexible, suggesting that it can be easily manipulated during insertion. ..
  20. pmc Utility of the Aintree Intubation Catheter in fiberoptic tracheal intubation through the three types of intubating supraglottic airways: a manikin simulation study
    Ryusuke Ueki
    Department of Anesthesiology, Hyogo College of Medicine, Mukogawa cho 1 1, Nishinomiya, Hyogo, 663 8501, Japan
    J Anesth 28:363-7. 2014
    ..The purpose of this study was to examine the utility of the Aintree Intubation Catheter (AIC) with three types of supraglottic airway devices for tracheal intubation (ISGAs) using a manikin...
  21. ncbi [Case of tension pneumothorax associated with asthma attack during general anesthesia]
    Nobuyasu Komasawa
    Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya 663 8501
    Masui 59:614-7. 2010
    ..She was extubated on postoperative day 1 without any neurological disorder. Hyperinflation of fragile alveoli by mechanical ventilation was likely a cause of tension pneumothorax...