Research Topics

Luca Poletto

Summary

Affiliation: University of Padova
Country: Italy

Publications

  1. ncbi Tolerances of time-delay-compensated monochromators for extreme-ultraviolet ultrashort pulses
    Luca Poletto
    CNR INFM LUXOR, Laboratory for UV and X Ray Optical Research and Department of Information Engineering, Padova, Italy
    Appl Opt 48:4526-35. 2009
  2. ncbi Time-delay compensated monochromator for the spectral selection of extreme-ultraviolet high-order laser harmonics
    Luca Poletto
    Laboratory for UV and X Ray Optical Research, CNR INFM and Department of Information Engineering, University of Padova, Padova 35131, Italy
    Rev Sci Instrum 80:123109. 2009
  3. ncbi Time-preserving grating monochromators for ultrafast extreme-ultraviolet pulses
    Luca Poletto
    National Research Council Institute of Photonics and Nanotechnologies, Laboratory for UV and X Ray Optical Research, Padova, Italy
    Appl Opt 49:5465-73. 2010
  4. ncbi Optical concept of a compressor for XUV pulses in the attosecond domain
    Fabio Frassetto
    CNR INFM Laboratory for Ultraviolet and X Ray Optical Research, Department of Information Engineering, University of Padova, Via Gradenigo 6 b, 35131 Padova, Italy
    Opt Express 16:6652-67. 2008
  5. ncbi Extreme-ultraviolet compact spectrometer for the characterization of the harmonics content in the free-electron-laser radiation at FLASH
    Fabio Frassetto
    Institute of Photonics and Nanotechnologies, National Research Council of Italy, Via Trasea 7, Padova 35131, Italy
    J Synchrotron Radiat 19:596-601. 2012

Collaborators

  • Fabio Frassetto
  • Natalia Gerasimova
  • Stefano Coraggia
  • Siarhei Dziarzhytski
  • Paolo Villoresi

Detail Information

Publications5

  1. ncbi Tolerances of time-delay-compensated monochromators for extreme-ultraviolet ultrashort pulses
    Luca Poletto
    CNR INFM LUXOR, Laboratory for UV and X Ray Optical Research and Department of Information Engineering, Padova, Italy
    Appl Opt 48:4526-35. 2009
    ..I compare here the two designs in terms of the tolerances in the alignment for time-delay compensation in the femtosecond time scale. The off-plane mount is demonstrated to be far superior to the classical diffraction mount...
  2. ncbi Time-delay compensated monochromator for the spectral selection of extreme-ultraviolet high-order laser harmonics
    Luca Poletto
    Laboratory for UV and X Ray Optical Research, CNR INFM and Department of Information Engineering, University of Padova, Padova 35131, Italy
    Rev Sci Instrum 80:123109. 2009
    ....
  3. ncbi Time-preserving grating monochromators for ultrafast extreme-ultraviolet pulses
    Luca Poletto
    National Research Council Institute of Photonics and Nanotechnologies, Laboratory for UV and X Ray Optical Research, Padova, Italy
    Appl Opt 49:5465-73. 2010
    ..e., 100-200 fs, while the OPM is suitable for ultrashort time responses in the 10-50 fs range to realize femtosecond time-preserving monochromators...
  4. ncbi Optical concept of a compressor for XUV pulses in the attosecond domain
    Fabio Frassetto
    CNR INFM Laboratory for Ultraviolet and X Ray Optical Research, Department of Information Engineering, University of Padova, Via Gradenigo 6 b, 35131 Padova, Italy
    Opt Express 16:6652-67. 2008
    ..The compressor can be designed for any spectral region in the XUV and soft X-ray domain. As a test case, the applications to the compression of attosecond pulses centered at 70 eV and at 160 eV are discussed...
  5. ncbi Extreme-ultraviolet compact spectrometer for the characterization of the harmonics content in the free-electron-laser radiation at FLASH
    Fabio Frassetto
    Institute of Photonics and Nanotechnologies, National Research Council of Italy, Via Trasea 7, Padova 35131, Italy
    J Synchrotron Radiat 19:596-601. 2012
    ..1-0.2% range. Both spectral and intensity fluctuations of the fundamental emission and the harmonics are monitored...