Giuseppe Lippi

Summary

Affiliation: University of Parma
Country: Italy

Publications

  1. Lippi G, Plebani M, Favaloro E. Interference in coagulation testing: focus on spurious hemolysis, icterus, and lipemia. Semin Thromb Hemost. 2013;39:258-66 pubmed publisher
    ..e., > 1,000 mg/dL) using high speed microcentrifugation or lipid extraction with organic solvents such as fluorine-chlorinated hydrocarbon, or lipid-clearing agents such as LipoClear (StatSpin Inc., Norwood, MA) and n-hexane...
  2. Lippi G, Favaloro E, Cervellin G. Prevention of venous thromboembolism: focus on mechanical prophylaxis. Semin Thromb Hemost. 2011;37:237-51 pubmed publisher
    ....
  3. Lippi G, Avanzini P, Dipalo M, Aloe R, Cervellin G. Influence of hemolysis on troponin testing: studies on Beckman Coulter UniCel Dxl 800 Accu-TnI and overview of the literature. Clin Chem Lab Med. 2011;49:2097-100 pubmed publisher
    ..Hemolyzed specimens are the leading pre-analytical problem in the laboratory practice, and exert a negative impact on test results. We assessed the reliability of Beckman Coulter UniCel Dxl 800 Accu-TnI testing on hemolyzed specimens...
  4. Lippi G, Schena F, Salvagno G, Aloe R, Banfi G, Guidi G. Foot-strike haemolysis after a 60-km ultramarathon. Blood Transfus. 2012;10:377-83 pubmed publisher
    ..The effective contribution of foot-strike haemolysis is unclear...
  5. Lippi G, Avanzini P, Cosmai M, Aloe R, Ernst D. Incomplete filling of lithium heparin tubes affects the activity of creatine kinase and gamma-glutamyltransferase. Br J Biomed Sci. 2012;69:67-70 pubmed
    ..3% and 16.6% for the half-draw and low-draw tubes, respectively. These results suggest that short-draw lithium heparin tubes might be unsuitable for testing GGT and CK using specific combinations of reagents and instrumentation. ..
  6. Lippi G. Biomarkers of myocardial ischemia in the emergency room: cardiospecific troponin and beyond. Eur J Intern Med. 2013;24:97-9 pubmed publisher
    ....
  7. Lippi G, Fontana R, Avanzini P, Sandei F, Ippolito L. Influence of spurious hemolysis on blood gas analysis. Clin Chem Lab Med. 2013;51:1651-4 pubmed publisher
    ..This study was hence planned to assess the influence of spurious hemolysis on venous blood gas analysis...
  8. Lippi G, Avanzini P, Cervellin G. Prevention of hemolysis in blood samples collected from intravenous catheters. Clin Biochem. 2013;46:561-4 pubmed publisher
    ..We planned a prospective, randomized study to establish whether hemolysis in samples drawn from intravenous catheters may be reduced using S-MonovetteĀ® tubes collected by manual aspiration as compared with standard vacuum tubes...
  9. Lippi G, Ippolito L, Zobbi V, Sandei F, Favaloro E. Sample collection and platelet function testing: influence of vacuum or aspiration principle on PFA-100 test results. Blood Coagul Fibrinolysis. 2013;24:666-9 pubmed publisher
    ..Different reference ranges of both CEPI and CADP may also be advisable when venous blood samples are collected with manual aspiration or vacuum principle...
  10. Lippi G, Chance J, Church S, Dazzi P, Fontana R, Giavarina D, et al. Preanalytical quality improvement: from dream to reality. Clin Chem Lab Med. 2011;49:1113-26 pubmed publisher
    ....

Detail Information

Publications15

  1. Lippi G, Plebani M, Favaloro E. Interference in coagulation testing: focus on spurious hemolysis, icterus, and lipemia. Semin Thromb Hemost. 2013;39:258-66 pubmed publisher
    ..e., > 1,000 mg/dL) using high speed microcentrifugation or lipid extraction with organic solvents such as fluorine-chlorinated hydrocarbon, or lipid-clearing agents such as LipoClear (StatSpin Inc., Norwood, MA) and n-hexane...
  2. Lippi G, Favaloro E, Cervellin G. Prevention of venous thromboembolism: focus on mechanical prophylaxis. Semin Thromb Hemost. 2011;37:237-51 pubmed publisher
    ....
  3. Lippi G, Avanzini P, Dipalo M, Aloe R, Cervellin G. Influence of hemolysis on troponin testing: studies on Beckman Coulter UniCel Dxl 800 Accu-TnI and overview of the literature. Clin Chem Lab Med. 2011;49:2097-100 pubmed publisher
    ..Hemolyzed specimens are the leading pre-analytical problem in the laboratory practice, and exert a negative impact on test results. We assessed the reliability of Beckman Coulter UniCel Dxl 800 Accu-TnI testing on hemolyzed specimens...
  4. Lippi G, Schena F, Salvagno G, Aloe R, Banfi G, Guidi G. Foot-strike haemolysis after a 60-km ultramarathon. Blood Transfus. 2012;10:377-83 pubmed publisher
    ..The effective contribution of foot-strike haemolysis is unclear...
  5. Lippi G, Avanzini P, Cosmai M, Aloe R, Ernst D. Incomplete filling of lithium heparin tubes affects the activity of creatine kinase and gamma-glutamyltransferase. Br J Biomed Sci. 2012;69:67-70 pubmed
    ..3% and 16.6% for the half-draw and low-draw tubes, respectively. These results suggest that short-draw lithium heparin tubes might be unsuitable for testing GGT and CK using specific combinations of reagents and instrumentation. ..
  6. Lippi G. Biomarkers of myocardial ischemia in the emergency room: cardiospecific troponin and beyond. Eur J Intern Med. 2013;24:97-9 pubmed publisher
    ....
  7. Lippi G, Fontana R, Avanzini P, Sandei F, Ippolito L. Influence of spurious hemolysis on blood gas analysis. Clin Chem Lab Med. 2013;51:1651-4 pubmed publisher
    ..This study was hence planned to assess the influence of spurious hemolysis on venous blood gas analysis...
  8. Lippi G, Avanzini P, Cervellin G. Prevention of hemolysis in blood samples collected from intravenous catheters. Clin Biochem. 2013;46:561-4 pubmed publisher
    ..We planned a prospective, randomized study to establish whether hemolysis in samples drawn from intravenous catheters may be reduced using S-MonovetteĀ® tubes collected by manual aspiration as compared with standard vacuum tubes...
  9. Lippi G, Ippolito L, Zobbi V, Sandei F, Favaloro E. Sample collection and platelet function testing: influence of vacuum or aspiration principle on PFA-100 test results. Blood Coagul Fibrinolysis. 2013;24:666-9 pubmed publisher
    ..Different reference ranges of both CEPI and CADP may also be advisable when venous blood samples are collected with manual aspiration or vacuum principle...
  10. Lippi G, Chance J, Church S, Dazzi P, Fontana R, Giavarina D, et al. Preanalytical quality improvement: from dream to reality. Clin Chem Lab Med. 2011;49:1113-26 pubmed publisher
    ....
  11. Lippi G, Franchini M, Targher G. Arterial thrombus formation in cardiovascular disease. Nat Rev Cardiol. 2011;8:502-12 pubmed publisher
    ..This Review explains mechanisms of pathological arterial thrombus formation and discusses genetic and acquired risk factors of atherothrombosis. ..
  12. Lippi G, Schena F, Salvagno G, Tarperi C, Aloe R, Guidi G. Comparison of conventional and highly-sensitive troponin I measurement in ultra-marathon runners. J Thromb Thrombolysis. 2012;33:338-42 pubmed publisher
    ..Moreover, the improved sensitivity of the HS-AccuTnI over the conventional assay makes it more suited for detecting even minor elevations of TnI in blood. ..
  13. Lippi G, Montagnana M, Meschi T, Comelli I, Cervellin G. Genetic and clinical aspects of Brugada syndrome: an update. Adv Clin Chem. 2012;56:197-208 pubmed
    ..Although molecular genetic testing is effective in detecting mutations in 20-38% of BS patients, it represents an appealing option for stratifying the risk of adverse events as well as for prenatal testing. ..
  14. Lippi G, Becan McBride K, Behulova D, Bowen R, Church S, Delanghe J, et al. Preanalytical quality improvement: in quality we trust. Clin Chem Lab Med. 2013;51:229-41 pubmed publisher
    ..Auditing of the preanalytical phase by ISO assessors and external quality assessment for preanalytical phase are also discussed. ..
  15. Lippi G, Mattiuzzi C, Cervellin G. Critical review and meta-analysis on the combination of heart-type fatty acid binding protein (H-FABP) and troponin for early diagnosis of acute myocardial infarction. Clin Biochem. 2013;46:26-30 pubmed publisher
    ..Further studies are needed to assess the diagnostic effectiveness of combining H-FABP with a high-sensitivity troponin immunoassay. ..