M Cassetta

Summary

Affiliation: University of Rome La Sapienza
Country: Italy

Publications

  1. ncbi request reprint High resolution 3-T MR imaging in the evaluation of the trigeminal nerve course
    M Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, and Department of Radiological, Oncology and Anatomo Pathological Sciences Sapienza University of Rome, Rome, Italy
    Eur Rev Med Pharmacol Sci 18:257-64. 2014
  2. doi request reprint How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide?
    M Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, Sapienza University of Rome, Rome, Italy Electronic address
    Int J Oral Maxillofac Surg 43:85-92. 2014
  3. ncbi request reprint Accuracy of two stereolithographic surgical templates: a retrospective study
    Michele Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, Sapienza University of Rome, Rome, Italy
    Clin Implant Dent Relat Res 15:448-59. 2013
  4. pmc Skeletal features in patient affected by maxillary canine impaction
    Emanuele Mercuri
    Department of Oral and Maxillo Facial Sciences, Sapienza, University of Rome, Italy
    Med Oral Patol Oral Cir Bucal 18:e597-602. 2013
  5. pmc Impaction of permanent mandibular second molar: a retrospective study
    Michele Cassetta
    Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Italy
    Med Oral Patol Oral Cir Bucal 18:e564-8. 2013
  6. doi request reprint Accuracy of a computer-aided implant surgical technique
    Michele Cassetta
    Department of Oral Sciences, School of Dentistry, Sapienza University of Rome, Rome, Italy
    Int J Periodontics Restorative Dent 33:317-25. 2013
  7. doi request reprint Is it possible to improve the accuracy of implants inserted with a stereolithographic surgical guide by reducing the tolerance between mechanical components?
    M Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, Sapienza University of Rome, Rome, Italy
    Int J Oral Maxillofac Surg 42:887-90. 2013
  8. doi request reprint The intrinsic error of a stereolithographic surgical template in implant guided surgery
    M Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, Sapienza University of Rome, Italy
    Int J Oral Maxillofac Surg 42:264-75. 2013
  9. ncbi request reprint The use of high resolution magnetic resonance on 3.0-T system in the diagnosis and surgical planning of intraosseous lesions of the jaws: preliminary results of a retrospective study
    M Cassetta
    Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Rome, Italy
    Eur Rev Med Pharmacol Sci 16:2021-8. 2012
  10. ncbi request reprint The impact of osteotomy technique for corticotomy-assisted orthodontic treatment (CAOT) on oral health-related quality of life
    M Cassetta
    Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Rome, Italy
    Eur Rev Med Pharmacol Sci 16:1735-40. 2012

Collaborators

Detail Information

Publications15

  1. ncbi request reprint High resolution 3-T MR imaging in the evaluation of the trigeminal nerve course
    M Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, and Department of Radiological, Oncology and Anatomo Pathological Sciences Sapienza University of Rome, Rome, Italy
    Eur Rev Med Pharmacol Sci 18:257-64. 2014
    ....
  2. doi request reprint How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide?
    M Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, Sapienza University of Rome, Rome, Italy Electronic address
    Int J Oral Maxillofac Surg 43:85-92. 2014
    ..The guide positioning error was found to affect the accuracy, but was statistically significant only for global coronal deviation (P = 0.038). Arch of support and mucosa thickness did not affect the guide positioning error...
  3. ncbi request reprint Accuracy of two stereolithographic surgical templates: a retrospective study
    Michele Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, Sapienza University of Rome, Rome, Italy
    Clin Implant Dent Relat Res 15:448-59. 2013
    ..The aim of this study was to evaluate and compare the mean accuracy and maximum deviations values of dental implant placement using two stereolithographic (SLA) guide systems...
  4. pmc Skeletal features in patient affected by maxillary canine impaction
    Emanuele Mercuri
    Department of Oral and Maxillo Facial Sciences, Sapienza, University of Rome, Italy
    Med Oral Patol Oral Cir Bucal 18:e597-602. 2013
    ..To analyze the skeletal features of patients with maxillary canine impaction...
  5. pmc Impaction of permanent mandibular second molar: a retrospective study
    Michele Cassetta
    Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Italy
    Med Oral Patol Oral Cir Bucal 18:e564-8. 2013
    ..The clinical significance of the angle between first and second mandibular molar and of the space between the first mandibular molar (MM1) and the anterior margin of mandibular ramus in MM2 impaction were also evaluated...
  6. doi request reprint Accuracy of a computer-aided implant surgical technique
    Michele Cassetta
    Department of Oral Sciences, School of Dentistry, Sapienza University of Rome, Rome, Italy
    Int J Periodontics Restorative Dent 33:317-25. 2013
    ..These results should serve as a warning for the clinician if implants are placed near vital structures...
  7. doi request reprint Is it possible to improve the accuracy of implants inserted with a stereolithographic surgical guide by reducing the tolerance between mechanical components?
    M Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, Sapienza University of Rome, Rome, Italy
    Int J Oral Maxillofac Surg 42:887-90. 2013
    ..02° (range 0.81-3.48°; standard deviation 0.87). The results of the present study show that by limiting the error that originates from mechanical components, the total error could be significantly reduced...
  8. doi request reprint The intrinsic error of a stereolithographic surgical template in implant guided surgery
    M Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, Sapienza University of Rome, Italy
    Int J Oral Maxillofac Surg 42:264-75. 2013
    ..The intrinsic error is a significant factor compared to all the variables that could potentially affect the accuracy of computer-aided implant placement...
  9. ncbi request reprint The use of high resolution magnetic resonance on 3.0-T system in the diagnosis and surgical planning of intraosseous lesions of the jaws: preliminary results of a retrospective study
    M Cassetta
    Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Rome, Italy
    Eur Rev Med Pharmacol Sci 16:2021-8. 2012
    ..The efficacy of these imaging methods in the evaluation of soft tissues is lower than magnetic resonance imaging (MRI)...
  10. ncbi request reprint The impact of osteotomy technique for corticotomy-assisted orthodontic treatment (CAOT) on oral health-related quality of life
    M Cassetta
    Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Rome, Italy
    Eur Rev Med Pharmacol Sci 16:1735-40. 2012
    ..Corticotomy in accelerating orthodontic tooth movement, also defined as corticotomy-assisted orthodontic treatment (CAOT), is a promising technique that recently had many applications in orthodontics...
  11. ncbi request reprint The influence of smoking and surgical technique on the accuracy of mucosa-supported stereolithographic surgical guide in complete edentulous upper jaws
    M Cassetta
    Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Rome, Italy
    Eur Rev Med Pharmacol Sci 16:1546-53. 2012
    ..The accuracy of a stereolithographic surgical guide depends on several variables that can affect at any time from the software-planning stage to the surgical field...
  12. ncbi request reprint The accuracy of CBCT in measuring jaws bone density
    M Cassetta
    Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Italy
    Eur Rev Med Pharmacol Sci 16:1425-9. 2012
    ..In the CBCT the dimensional accuracy is also comparable with Computer Tomography (CT), but in contrast to the CT, the gray density values of the CBCT images (voxel value [VV]) are not absolute...
  13. doi request reprint Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide
    M Cassetta
    Department of Oral and Maxillo Facial Sciences, School of Dentistry, Sapienza University of Rome, Italy
    Int J Oral Maxillofac Surg 40:1377-87. 2011
    ....
  14. ncbi request reprint Comparing proton density and turbo spin echo T2 weighted static sequences with dynamic half-Fourier single-shot TSE pulse sequence at 3.0 T in diagnosis of temporomandibular joint disorders: a prospective study
    M Cassetta
    Department of Oral and Maxillofacial Sciences, School of Dentistry, Sapienza University of Rome, Rome, Italy
    Dentomaxillofac Radiol 43:20130387. 2014
    ..The aim of this prospective study was to compare dynamic and static sequences in the evaluation of temporomandibular joint disorders using a 3.0 -T imaging unit...