Joseph Rosen

Summary

Affiliation: Ben-Gurion University of the Negev
Country: Israel

Publications

  1. ncbi Theoretical and experimental demonstration of resolution beyond the Rayleigh limit by FINCH fluorescence microscopic imaging
    Joseph Rosen
    Department of Biomedical Engineering, Johns Hopkins University, Rockville, Maryland 20850, USA
    Opt Express 19:26249-68. 2011
  2. ncbi Noninvasive optical imaging by speckle ensemble
    Joseph Rosen
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, P O Box 653, Beer Sheva 84105, Israel
    Opt Lett 29:253-5. 2004
  3. ncbi Super-resolution in incoherent optical imaging using synthetic aperture with Fresnel elements
    Barak Katz
    Department of Electrical and Computer Engineering Ben Gurion University of the Negev, Beer Sheva, Israel
    Opt Express 18:962-72. 2010
  4. ncbi Optimal resolution in Fresnel incoherent correlation holographic fluorescence microscopy
    Gary Brooker
    Department of Biomedical Engineering, Johns Hopkins University, 9605 Medical Center Drive, Rockville, Maryland 20850 USA
    Opt Express 19:5047-62. 2011
  5. ncbi NOISE 2 imaging system: seeing through scattering tissue with a reference point
    David Abookasis
    Department of Electrical and Computer Engineering, Ben-Gurion University of the Negev, P.O. Box 653, Beer-Sheva 84105, Israel
    Opt Lett 29:956-8. 2004
  6. ncbi Recovery of partially occluded objects by applying compressive Fresnel holography
    Yair Rivenson
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, Beer Sheva, Israel
    Opt Lett 37:1757-9. 2012
  7. ncbi Reconstruction of objects above and below the objective focal plane with dimensional fidelity by FINCH fluorescence microscopy
    Nisan Siegel
    Department of Biomedical Engineering, Johns Hopkins University, 9605 Medical Center Drive, Rockville, Maryland 20850, USA
    Opt Express 20:19822-35. 2012
  8. ncbi Enhanced resolution and throughput of Fresnel incoherent correlation holography (FINCH) using dual diffractive lenses on a spatial light modulator (SLM)
    Barak Katz
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, P O Box 653, Beer Sheva 84105, Israel
    Opt Express 20:9109-21. 2012
  9. ncbi Compressive multiple view projection incoherent holography
    Yair Rivenson
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, Beer Sheva, Israel
    Opt Express 19:6109-18. 2011
  10. ncbi Spatially incoherent single channel digital Fourier holography
    Roy Kelner
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, Beer Sheva 84105, Israel
    Opt Lett 37:3723-5. 2012

Collaborators

Detail Information

Publications15

  1. ncbi Theoretical and experimental demonstration of resolution beyond the Rayleigh limit by FINCH fluorescence microscopic imaging
    Joseph Rosen
    Department of Biomedical Engineering, Johns Hopkins University, Rockville, Maryland 20850, USA
    Opt Express 19:26249-68. 2011
    ..We demonstrate, theoretically and experimentally, improved resolution by FINCH, when compared to conventional imaging...
  2. ncbi Noninvasive optical imaging by speckle ensemble
    Joseph Rosen
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, P O Box 653, Beer Sheva 84105, Israel
    Opt Lett 29:253-5. 2004
    ..Each lens is the array projects a different speckled image onto a digital camera. The set of speckled images from the entire array is first shifted to a common center and then accumulated into a single average picture...
  3. ncbi Super-resolution in incoherent optical imaging using synthetic aperture with Fresnel elements
    Barak Katz
    Department of Electrical and Computer Engineering Ben Gurion University of the Negev, Beer Sheva, Israel
    Opt Express 18:962-72. 2010
    ..This method is demonstrated experimentally by combining three holographic elements recorded with white light illumination which is emitted from a binary grating...
  4. ncbi Optimal resolution in Fresnel incoherent correlation holographic fluorescence microscopy
    Gary Brooker
    Department of Biomedical Engineering, Johns Hopkins University, 9605 Medical Center Drive, Rockville, Maryland 20850 USA
    Opt Express 19:5047-62. 2011
    ..Results from imaging a fluorescent USAF pattern and a pollen grain slide reveal resolution which approaches the Rayleigh limit by this simple method for 3D fluorescent microscopic imaging...
  5. ncbi NOISE 2 imaging system: seeing through scattering tissue with a reference point
    David Abookasis
    Department of Electrical and Computer Engineering, Ben-Gurion University of the Negev, P.O. Box 653, Beer-Sheva 84105, Israel
    Opt Lett 29:956-8. 2004
    ..A set of the squared magnitudes of the Fourier-transformed pictures is accumulated to form a single average picture. This final picture is again Fourier transformed, resulting in the reconstruction of the hidden object...
  6. ncbi Recovery of partially occluded objects by applying compressive Fresnel holography
    Yair Rivenson
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, Beer Sheva, Israel
    Opt Lett 37:1757-9. 2012
    ..Reconstruction guarantees are analyzed and the effectiveness of the method is demonstrated using simulations and an experimental result showing the reconstruction of a partially occluded resolution chart...
  7. ncbi Reconstruction of objects above and below the objective focal plane with dimensional fidelity by FINCH fluorescence microscopy
    Nisan Siegel
    Department of Biomedical Engineering, Johns Hopkins University, 9605 Medical Center Drive, Rockville, Maryland 20850, USA
    Opt Express 20:19822-35. 2012
    ..Because FINCH is inherently a super-resolving system, this advance makes it possible to create super-resolved 3D images from FINCH holograms...
  8. ncbi Enhanced resolution and throughput of Fresnel incoherent correlation holography (FINCH) using dual diffractive lenses on a spatial light modulator (SLM)
    Barak Katz
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, P O Box 653, Beer Sheva 84105, Israel
    Opt Express 20:9109-21. 2012
    ..The improved quality of the hologram results from a reduced optical path difference of the interfering beams and increased efficiency...
  9. ncbi Compressive multiple view projection incoherent holography
    Yair Rivenson
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, Beer Sheva, Israel
    Opt Express 19:6109-18. 2011
    ..It is also shown that the compressive sensing approach, combined with an appropriate system model, yields improved sectioning of the planes of different depths...
  10. ncbi Spatially incoherent single channel digital Fourier holography
    Roy Kelner
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, Beer Sheva 84105, Israel
    Opt Lett 37:3723-5. 2012
    ..A single exposure recorded by a digital camera is sufficient to record a real-valued hologram that encodes the complete three-dimensional properties of an object...
  11. ncbi Optimal noise suppression in Fresnel incoherent correlation holography (FINCH) configured for maximum imaging resolution
    Barak Katz
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, P O Box 653, Beer Sheva 84105, Israel
    Appl Opt 49:5757-63. 2010
    ..These methods improve the resolution of the reconstructed image due to their ability to reveal fine and weak details of the observed object...
  12. ncbi Fluorescence multicolor hologram recorded by using a macrolens array
    Natan T Shaked
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, PO Box 653, Beer Sheva 84105, Israel
    Opt Lett 33:1461-3. 2008
    ..The 3-D reconstructed images from all the monochromatic holograms are composed into a single multicolor image of the 3-D scene. The proposed holographic technique is demonstrated by experiments...
  13. ncbi Could SAFE concept be applied for designing a new synthetic aperture telescope?
    Barak Katz
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, P O Box 653, Beer Sheva 84105, Israel
    Opt Express 19:4924-36. 2011
    ..In this paper we investigate a new scheme of SAFE which may be used as a basis for designing a new type of synthetic aperture telescopes. Laboratory in-door experiments may provide the proof of concept for such a new design...
  14. ncbi Homodyne scanning holography
    Joseph Rosen
    Department of Electrical and Computer Engineering, Ben Gurion University of the Negev, P O Box 653 Beer Sheva 84105, http www ee bgu ac il approximately rosen
    Opt Express 14:4280-5. 2006
    ..In each scanning period the system produces an on-axis Fresnel hologram. The twin image problem is solved by a linear combination of at least three holograms taken with three FZPs with different phase values...
  15. ncbi Scanning holographic microscopy with resolution exceeding the Rayleigh limit of the objective by superposition of off-axis holograms
    Guy Indebetouw
    Department of Physics, Virginia Tech, Blacksburg, Virginia 24061 0435, USA
    Appl Opt 46:993-1000. 2007
    ..The method is demonstrated experimentally by combining three off-axis holograms of fluorescent beads showing a transverse resolution gain of nearly a factor of 2...