Coasting: worth the effort?J F A Hendrickx
Department of Anesthesiology, Intensive Care and Pain Therapy, Onze Lieve Vrouwziekenhuis, Aalst, Belgium
Acta Anaesthesiol Belg 62:147-50. 2011
....
Mathematical method to build an empirical model for inhaled anesthetic agent wash-inJan Fa Hendrickx
Department of Anesthesiology, Intensive Care and Pain Therapy, Onze Lieve Vrouwziekenhuis, Aalst, Belgium
BMC Anesthesiol 11:13. 2011
..abstract:..
Development and performance of a two-step desflurane-O(2)/N(2)O fresh gas flow sequenceJan F A Hendrickx
Department of Anesthesiology, Intensive Care and Pain Therapy, Onze Lieve Vrouw Hospital, Aalst, Belgium
J Clin Anesth 20:501-7. 2008
..5% with the anesthesia delivery unit machine (ADU Anesthesia Machine(R); General Electric, Helsinki, Finland)...
Desflurane consumption during automated closed-circuit delivery is higher than when a conventional anesthesia machine is used with a simple vaporizer-O2-N2O fresh gas flow sequenceSofie De Cooman
Department of Anesthesiology, Intensive Care and Pain Therapy, Onze Lieve Vrouw Hospital, Aalst, Belgium
BMC Anesthesiol 8:4. 2008
....
Is synergy the rule? A review of anesthetic interactions producing hypnosis and immobilityJan F A Hendrickx
Department of Anesthesia, Onze Lieve Vrouw Hospital, Moorselbaan 164, 9300 Aalst, Belgium
Anesth Analg 107:494-506. 2008
..We applied this reasoning in a review of published data on anesthetic drug interactions for the end-points of hypnosis and immobility...
Can Modern Infrared Analyzers Replace Gas Chromatography to Measure Anesthetic Vapor Concentrations?Jan Fa Hendrickx
Department of Anesthesia, Stanford University School of Medicine, Stanford, California, USA
BMC Anesthesiol 8:2. 2008
..We examined the accuracy of a modern IR analyzer (M-CAiOV compact gas IR analyzer (General Electric, Helsinki, Finland) by comparing its performance with GC...
The ideal oxygen/nitrous oxide fresh gas flow sequence with the Anesthesia Delivery Unit machineJan F A Hendrickx
Department of Anesthesiology, Intensive Care and Pain Therapy, Onze Lieve Vrouw Hospital, 9300 Aalst, Belgium
J Clin Anesth 19:274-9. 2007
..7 L/min could be accomplished while maintaining end-expired nitrous oxide concentration > or =50% with an Anesthesia Delivery Unit anesthesia machine...
Large volume N2O uptake alone does not explain the second gas effect of N2O on sevoflurane during constant inspired ventilationJ F A Hendrickx
Department of Anesthesia, Stanford University School of Medicine, Stanford, CA 94305 5640, USA
Br J Anaesth 96:391-5. 2006
....
Pharmacokinetics of inhaled anesthetics and the general anesthetic equation--a reappraisalJ F A Hendrickx
Department of Anesthesiology/CCM, OLV Hospital, Aalst, Belgium
Acta Anaesthesiol Belg 54:49-57. 2003
Desflurane consumption with the Zeus during automated closed circuit versus low flow anesthesiaS De Cooman
Department of Anesthesiology, Institut Jules Bordet, Universite Libre de Bruxelles, Brussels, Belgium
Acta Anaesthesiol Belg 60:35-7. 2009
..7 L min(-1)) with 3 different carrier gases...
Pulmonary gas exchange is well preserved during robot assisted surgery in steep Trendelenburg positionD Schrijvers
Department of Anesthesiology, OLV Hospital, Aalst, Belgium
Acta Anaesthesiol Belg 60:229-33. 2009
..The extent to which oxygenation and ventilation might be compromised intra-operatively remains poorly documented...
Effect of N2O on sevoflurane vaporizer settings during minimal- and low-flow anesthesiaJan F A Hendrickx
Department of Anesthesiology, Intensive Care and Pain Therapy, Onze Lieve Vrouw Hospital, Aalst, Belgium
Anesthesiology 97:400-4. 2002
..However, other unexplored factors affecting gas kinetics in a circle system may contribute to our observations...
Additivity versus synergy: a theoretical analysis of implications for anesthetic mechanismsSteven L Shafer
Department of Anesthesiology, Columbia University Medical Center, 622 W 168th St, PH 5 505, New York, NY 10032 3725, USA
Anesth Analg 107:507-24. 2008
..Synergy implies multiple sites of action by definition. In this essay, we explore the converse: does additivity imply a single site of action?..
Severe ADU desflurane vaporizing unit malfunctionJan F A Hendrickx
Anesthesiology 99:1459-60; author reply 1460. 2003
Isoflurane and desflurane uptake during liver resection and transplantationJan F A Hendrickx
Department of Anesthesiology and CCM, University of Pittsburgh School of Medicine, Pennsylvania, USA
Anesth Analg 96:356-62, table of contents. 2003
..However, the slowly decreasing rate of uptake during prolonged procedures suggests that the number of vaporizer adjustments to keep the end-expired concentration constant should be limited...