Research Topics
| S KottouSummaryAffiliation: University of Athens Country: Greece Publications
| Collaborators
|
Detail Information
Publications
Personnel doses in haemodynamic units in GreeceS Kottou
Athens University, Medical Physics Dept, Medical School, 75 M Asias str, Athens, Greece
Radiat Prot Dosimetry 94:121-4. 2001..Evaluation of risk level and check of compliance with regulatory dose limits should be part of continuing radiation protection education...
Intercomparison of TL dosimetry (DIMOND programme)S Kottou
Medical Physics Dept, Medical School, Athens University, 75 M Asias str, Athens, Greece
Radiat Prot Dosimetry 94:125-8. 2001..Irradiating set-up conditions, evaluated doses, as well as comparison of mean values with the 'true' nominal doses are presented and discussed...
Level of patient and operator dose in the largest cardiac centre in GreeceV Tsapaki
Konstantopoulio Agia Olga Hospital, 3 5 Agias Olgas Street, Nea Ionia, Athens, Greece
Radiat Prot Dosimetry 129:71-3. 2008..6, 27 and 13 microSv, respectively, per procedure. The great range of radiation doses received by both patients and operators confirms the need for continuous monitoring of all IC techniques...
Patient dose, image quality and radiographic techniques for common X ray examinations in two Greek hospitals and comparison with European guidelinesD Papadimitriou
Department of Medical Physics, University of Athens, School of Medicine, 75 Mikras Asias, Goudi 11527, Athens, Greece
Radiat Prot Dosimetry 95:43-8. 2001..All four X ray rooms in the survey achieved mean doses well below the European reference doses. However the mean doses in the X ray rooms differed by a factor of about 3...
High patient doses in interventional cardiology due to physicians' negligence: how can they be prevented?I Mavrikou
Medical Physics Department, Athens General Hospital, 154 Mesogion Avenue, Athens, Greece
Radiat Prot Dosimetry 129:67-70. 2008..The question to answer next is how this bad practice can be prevented since no dose constraints apply to diagnostic or therapeutic procedures using ionising radiation...
Patient skin dose assessment during CT-guided interventional proceduresV Tsapaki
Konstantopoulio Hospital, 3 5 Agias Olgas str, Nea Ionia, Athens, Greece
Radiat Prot Dosimetry 129:29-31. 2008..2 Gy). For these procedures, an alternative method should be investigated...
Commissioning and constancy protocols for digital angiographic unitsV Tsapaki
Medical Physics Department, Konstantopoulio Agia Olga Hospital, Athens, Greece
Radiat Prot Dosimetry 129:258-60. 2008..The commissioning protocol was tested by SENTINEL partners who expressed an interest in checking their dynamic digital systems using this protocol. The results of basic tests are reported...
Comparison of a conventional and a flat-panel digital system in interventional cardiology proceduresV Tsapaki
Medical Physics Department, Konstantopoulio Agia Olga Hospital, Medical Physics Department, Medical School, Athens University, Athens, Greece
Br J Radiol 77:562-7. 2004..The results of the study concerning the FPF system lead to the conclusion that the lowest fluoroscopic mode and the lowest frame rate should be used in routine practice...
Patient dose values in a dedicated Greek cardiac centreV Tsapaki
Department of Bioengineering, Onassis Cardiac Surgery Centre, Athens, Greece
Br J Radiol 76:726-30. 2003..Analysis of the patient dose values obtained initiated a program of radiation protection optimization. The need for continuous training in radiation protection for interventionalists has been verified...
Radiation dose measurements to the interventional cardiologist using an electronic personal dosemeterV Tsapaki
Medical Physics Department, Konstantopoulio Agia Olga Hospital, Athens, Greece
Radiat Prot Dosimetry 112:245-9. 2004..2 microSv in CA and 0.3 microSv in PTCA. EPD proved to be an easy, direct and straightforward way to measure the radiation dose that the cardiologist receives in an IC laboratory...
A survey of 14 computed tomography scanners in Greece and 32 scanners in Italy. Examination frequencies, dose reference values, effective doses and doses to organsD Papadimitriou
Medical Physics Dept, University of Athens, School of Medicine 75 M Asias Str, 11527 Athens, Greece
Radiat Prot Dosimetry 104:47-53. 2003..2 +/- 19.8 mGy during a cervical spine examination while the gonads receive 17.8 +/- 6.9 mGy during a routine pelvis examination...
Quality assurance (QA) procedures for software: evaluation of an ADC quality systemE P Efstathopoulos
Second Department of Radiology, Medical School, University of Athens, General Hospital Attikon, Rimini 1, 124 62, Athens, Greece
Radiat Prot Dosimetry 117:291-7. 2005..It was discovered that the processing software evaluated in this study was able to improve some aspects of image quality, without introducing geometric distortion...
Investigation of breast dose in five screening mammography centres in GreeceV Tsapaki
Medical Physics Department, Konstantopoulio Hospital, Nea Ionia, 142 33, Athens, Greece
J Radiol Prot 28:337-46. 2008..5 cm CBT. However, the variety of techniques observed revealed the need for a nationwide survey concerning screening mammography in Greece...
Does digital imaging decrease patient dose? A pilot study and review of the literatureV Neofotistou
Medical Physics Department, Athens General Hospital, 11527 Athens, Greece
Radiat Prot Dosimetry 117:204-10. 2005..Clinical trials are required in order to define reference levels associated with quality of digital image necessary to address specific clinical requirements...
On the use of DICOM cine header information for optimisation: results from the 2002 European DIMOND cardiology surveyE Vano
Radiology and Medical Physics, San Carlos Hospital Complutense University, Madrid, Spain
Radiat Prot Dosimetry 117:162-5. 2005..5 and 15.4 and the mean number of frames per procedure between 575 and 1417. Differences in kVp, mA, pulse time, distances and C-arm angulations are substantial and suggest that there exists a wide range for optimisation...
Patient dose in interventional radiology: a European surveyE Vano
Radiology Department, Ciudad Universitaria, Complutense University, Madrid, Spain
Radiat Prot Dosimetry 129:39-45. 2008..There is a need to improve the optimisation of IR procedures and their definitions and grouping, in order to account for their different complexities...
Survey on performance assessment of cardiac angiography systemsR Padovani
Medical Physics Department, Udine Hospital, Italy
Radiat Prot Dosimetry 129:108-11. 2008..Results from this survey could contribute to the explanation of patient dose variability in angiographic cardiac procedures and to derive reference levels for cardiac angiographic equipment performance parameters...
Quality control measurements for fluoroscopy systems in eight countries participating in the SENTINEL EU coordination actionJ Zoetelief
Faculty of Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands
Radiat Prot Dosimetry 129:237-43. 2008..Only one participant was able to perform the monitor test using MoniQA. This is due to the fact that assistance is required from the suppliers of the X-ray systems. This problem needs to be solved to apply MoniQA in practice...
Comparison of a CCD and a flat-panel digital system in an Interventional Cardiology LaboratoryV Tsapaki
Medical Physics Department, Konstantopoulio Agia Olga Hospital, 3-5 Agias Olgas, Nea Ionia, 14233 Athens, Greece
Radiat Prot Dosimetry 117:93-6. 2005....
Application of European Commission reference dose levels in CT examinations in Crete, GreeceV Tsapaki
Euromedica Medical Center, 44 Demokratius Str, 176174 Iraklion, Crete, Greece
Br J Radiol 74:836-40. 2001..It is anticipated that a reduction of L, or product mAs, or their combination, will reduce DLP without affecting image quality...
Correlation of patient and staff doses in interventional cardiologyV Tsapaki
Medical Physics Department, Konstantopoulio Agia Olga Hospital, 3-5 Agias Olgas, Nea Ionia, 14233 Athens, Greece
Radiat Prot Dosimetry 117:26-9. 2005..69). DAP and foot dose correlation was poor both in CA (R2 = 0.16) and in PTCA (R2 = 0.02). Protective measures taken by staff varied between countries, which may explain the poor correlation of patient and staff radiation doses...