Thomas Weber

Summary

Affiliation: University of Erlangen-Nuremberg
Country: Germany

Publications

  1. ncbi request reprint Noise in x-ray grating-based phase-contrast imaging
    Thomas Weber
    ECAP Erlangen Centre for Astroparticle Physics, University of Erlangen Nuremberg, Erwin Rommel Str 1, 91058 Erlangen, Germany
    Med Phys 38:4133-40. 2011
  2. doi request reprint Grating-based darkfield imaging of human breast tissue
    Gisela Anton
    Erlangen Centre for Astroparticle Physics, Friedrich Alexander Universitat Erlangen Nurnberg, Erwin Rommel Str 1, 91058 Erlangen, Germany
    Z Med Phys 23:228-35. 2013
  3. doi request reprint On a dark-field signal generated by micrometer-sized calcifications in phase-contrast mammography
    Thilo Michel
    Erlangen Centre for Astroparticle Physics ECAP, Friedrich Alexander Universitat Erlangen Nurnberg, Erwin Rommel Str 1, D 91058 Erlangen, Germany
    Phys Med Biol 58:2713-32. 2013

Collaborators

  • Thilo Michel
  • Gisela Anton
  • Marcus Radicke
  • Peter A Fasching
  • Florian Bayer
  • Michael Uder
  • Jens Rieger
  • Claudia Rauh
  • David L Wachter
  • Arndt Hartmann
  • Rudiger Schulz-Wendtland
  • Jürgen Durst
  • Georg Pelzer
  • Matthias W Beckmann
  • Wilhelm Haas
  • Evelyn Wenkel
  • André Ritter
  • Peter Sievers
  • Andrea Zang
  • Lukas Wucherer

Detail Information

Publications3

  1. ncbi request reprint Noise in x-ray grating-based phase-contrast imaging
    Thomas Weber
    ECAP Erlangen Centre for Astroparticle Physics, University of Erlangen Nuremberg, Erwin Rommel Str 1, 91058 Erlangen, Germany
    Med Phys 38:4133-40. 2011
    ..While these many possible applications arise, the knowledge of the noise behavior is essential...
  2. doi request reprint Grating-based darkfield imaging of human breast tissue
    Gisela Anton
    Erlangen Centre for Astroparticle Physics, Friedrich Alexander Universitat Erlangen Nurnberg, Erwin Rommel Str 1, 91058 Erlangen, Germany
    Z Med Phys 23:228-35. 2013
    ..Comparison with the histomorphometric image proofs that the darkfield signal correlates with a tumor region containing small calcification grains of 3 to 30μm size. ..
  3. doi request reprint On a dark-field signal generated by micrometer-sized calcifications in phase-contrast mammography
    Thilo Michel
    Erlangen Centre for Astroparticle Physics ECAP, Friedrich Alexander Universitat Erlangen Nurnberg, Erwin Rommel Str 1, D 91058 Erlangen, Germany
    Phys Med Biol 58:2713-32. 2013
    ..We conclude that some tumors which are invisible in x-ray absorption mammography might be detected in the x-ray dark-field image at tolerable dose levels...