D Strobel

Summary

Affiliation: University of Erlangen-Nuremberg
Country: Germany

Publications

  1. doi request reprint Contrast-enhanced ultrasound for the characterization of focal liver lesions--diagnostic accuracy in clinical practice (DEGUM multicenter trial)
    D Strobel
    Internal Medicine I, University of Erlangen, Erlangen
    Ultraschall Med 29:499-505. 2008
  2. pmc Diagnostics in inflammatory bowel disease: ultrasound
    Deike Strobel
    Department of Medicine I, Division of Ultrasound, University of Erlangen, Ulmenweg 18, D 91054 Erlangen, Germany
    World J Gastroenterol 17:3192-7. 2011
  3. doi request reprint Diagnostic accuracy of CEUS in the differential diagnosis of small (≤ 20  mm) and subcentimetric (≤ 10  mm) focal liver lesions in comparison with histology. Results of the DEGUM multicenter trial
    D Strobel
    Dept of Medicine 1, University of Erlangen, Germany
    Ultraschall Med 32:593-7. 2011
  4. doi request reprint Tumor-specific vascularization pattern of liver metastasis, hepatocellular carcinoma, hemangioma and focal nodular hyperplasia in the differential diagnosis of 1,349 liver lesions in contrast-enhanced ultrasound (CEUS)
    D Strobel
    Internal Medicine I, University of Erlangen, Ulmenweg 18, 91058 Erlangen
    Ultraschall Med 30:376-82. 2009
  5. doi request reprint Efficacy of contrast-enhanced US versus CT or MRI for the therapeutic control of percutaneous radiofrequency ablation in the case of hepatic malignancies
    M Frieser
    Department of Medicine I, NOZ, Erlangen, Germany
    Ultraschall Med 32:148-53. 2011
  6. doi request reprint Characterization of focal liver lesions (FLL) with acoustic radiation force impulse (ARFI) elastometry
    R Heide
    Departement of Internal Medicine 1, University of Erlangen, Germany
    Ultraschall Med 31:405-9. 2010
  7. doi request reprint [Spectrum and bleeding complications of sonographically guided interventions of the liver and pancreas]
    M Frieser
    Medizinische Klinik 1, NOZ, Universitat Erlangen Nurnberg, Ulmenweg 18, Erlangen
    Ultraschall Med 30:168-74. 2009
  8. doi request reprint Dynamic contrast-enhanced ultrasound (DCE-US) for easy and rapid evaluation of hepatocellular carcinoma compared to dynamic contrast-enhanced computed tomography (DCE-CT)--a pilot study
    C Egger
    Departement of Internal Medecine 1, University of Erlangen, Germany
    Ultraschall Med 33:587-92. 2012
  9. ncbi request reprint Detection of liver metastases: comparison of contrast-enhanced wide-band harmonic imaging with conventional ultrasonography
    T Bernatik
    Department of Internal Medicine I, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
    J Ultrasound Med 20:509-15. 2001
  10. ncbi request reprint Radiofrequency ablation using perfused needle electrodes - study of intermittent and continuous triple needle application ex vivo
    M Frieser
    Department of Medicine I, Friedrich Alexander University, Erlangen, Germany
    Eur Surg Res 37:312-6. 2005

Detail Information

Publications23

  1. doi request reprint Contrast-enhanced ultrasound for the characterization of focal liver lesions--diagnostic accuracy in clinical practice (DEGUM multicenter trial)
    D Strobel
    Internal Medicine I, University of Erlangen, Erlangen
    Ultraschall Med 29:499-505. 2008
    ..To evaluate the diagnostic benefit of contrast-enhanced ultrasound for the differential diagnosis of liver tumors in clinical practice...
  2. pmc Diagnostics in inflammatory bowel disease: ultrasound
    Deike Strobel
    Department of Medicine I, Division of Ultrasound, University of Erlangen, Ulmenweg 18, D 91054 Erlangen, Germany
    World J Gastroenterol 17:3192-7. 2011
    ..This article focuses on the current clinical practice of US in IBD, describing the current technologies used in transabdominal intestinal US and the characteristic sonographic findings in Crohn´s disease and ulcerative colitis...
  3. doi request reprint Diagnostic accuracy of CEUS in the differential diagnosis of small (≤ 20  mm) and subcentimetric (≤ 10  mm) focal liver lesions in comparison with histology. Results of the DEGUM multicenter trial
    D Strobel
    Dept of Medicine 1, University of Erlangen, Germany
    Ultraschall Med 32:593-7. 2011
    ..To evaluate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in the differential diagnosis of small and subcentimetric liver tumors in clinical practice...
  4. doi request reprint Tumor-specific vascularization pattern of liver metastasis, hepatocellular carcinoma, hemangioma and focal nodular hyperplasia in the differential diagnosis of 1,349 liver lesions in contrast-enhanced ultrasound (CEUS)
    D Strobel
    Internal Medicine I, University of Erlangen, Ulmenweg 18, 91058 Erlangen
    Ultraschall Med 30:376-82. 2009
    ..To evaluate the incidence and diagnostic accuracy of tumor-specific vascularization pattern in contrast-enhanced ultrasound (CEUS) in the differential diagnosis of liver tumors in clinical practice...
  5. doi request reprint Efficacy of contrast-enhanced US versus CT or MRI for the therapeutic control of percutaneous radiofrequency ablation in the case of hepatic malignancies
    M Frieser
    Department of Medicine I, NOZ, Erlangen, Germany
    Ultraschall Med 32:148-53. 2011
    ..Patients who had undergone RFA of malignant liver tumors were followed up with contrast-enhanced sonography (CEUS), computed tomography (CT) and/or magnetic resonance tomography (MRI), and the outcomes were compared...
  6. doi request reprint Characterization of focal liver lesions (FLL) with acoustic radiation force impulse (ARFI) elastometry
    R Heide
    Departement of Internal Medicine 1, University of Erlangen, Germany
    Ultraschall Med 31:405-9. 2010
    ..The aim of this prospective pilot study was to evaluate the role of ARFI elastometry of focal liver lesions (FLL) and the surrounding liver parenchyma...
  7. doi request reprint [Spectrum and bleeding complications of sonographically guided interventions of the liver and pancreas]
    M Frieser
    Medizinische Klinik 1, NOZ, Universitat Erlangen Nurnberg, Ulmenweg 18, Erlangen
    Ultraschall Med 30:168-74. 2009
    ..Interventions with needles with a larger diameter seem to cause more complications. In search of potential complications, we examined 1923 sonographically guided interventions of the liver and pancreas in a retrospective analysis...
  8. doi request reprint Dynamic contrast-enhanced ultrasound (DCE-US) for easy and rapid evaluation of hepatocellular carcinoma compared to dynamic contrast-enhanced computed tomography (DCE-CT)--a pilot study
    C Egger
    Departement of Internal Medecine 1, University of Erlangen, Germany
    Ultraschall Med 33:587-92. 2012
    ....
  9. ncbi request reprint Detection of liver metastases: comparison of contrast-enhanced wide-band harmonic imaging with conventional ultrasonography
    T Bernatik
    Department of Internal Medicine I, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
    J Ultrasound Med 20:509-15. 2001
    ..CONCLUSIONS: The use of contrast-enhanced imaging techniques significantly improves the ultrasonographic detection of liver metastases. Our results achieved the sensitivity of biphasic helical computed tomography...
  10. ncbi request reprint Radiofrequency ablation using perfused needle electrodes - study of intermittent and continuous triple needle application ex vivo
    M Frieser
    Department of Medicine I, Friedrich Alexander University, Erlangen, Germany
    Eur Surg Res 37:312-6. 2005
    ..Intermittent energy application heats up the necrosis faster and more evenly with highest average temperature than continuous energy application...
  11. ncbi request reprint Radiofrequency ablation of liver tumors: how to enlarge the necrotic zones?
    M Frieser
    Department of Medicine I, Friedrich Alexander University, Erlangen Nuremberg, Germany
    Eur Surg Res 36:357-61. 2004
    ..By contrast, increasing the perfusion rate produced significantly larger necrotic zones. Doubling the perfusion rate made it possible to reach higher temperatures (>60 degrees C) within significantly shorter time...
  12. ncbi request reprint Dynamic contrast-enhanced power Doppler sonography improves the differential diagnosis of liver lesions
    D Strobel
    Department of Medicine I, Friedrich Alexander University of Erlangen Nuremberg, Germany
    Int J Colorectal Dis 16:247-56. 2001
    ..Contrast-enhanced power Doppler sonography improves diagnostic accuracy in the differential diagnosis of focal liver lesions...
  13. ncbi request reprint Hepatic transit time: indicator of the therapeutic response to radiofrequency ablation of liver tumours
    X Zhou
    Department of Ultrasound, Friedrich Alexander University Erlangen Nurnberg, Ulmenweg 18, D 91054 Erlangen, Germany
    Br J Radiol 78:433-6. 2005
    ..3+/-1.8 s). Successful RFA leads to a normalization in HTT. HTT using ultrasound contrast agent appears to provide a new and alternative approach in assessing the therapeutic effect of RFA in liver metastases...
  14. doi request reprint Mesenteric transit time using contrast-enhanced ultrasound (CEUS) does not correlate with disease activity in Crohn's disease
    R S Goertz
    Departement of Internal Medicine 1, University of Erlangen, Germany
    Ultraschall Med 33:164-9. 2012
    ..Evaluation of mesenteric transit time (MTT) - measured by contrast-enhanced ultrasound - as a marker for inflammatory activity in Crohn's disease...
  15. ncbi request reprint Echo-enhanced color- and power-Doppler EUS for the discrimination between focal pancreatitis and pancreatic carcinoma
    D Becker
    Department of Medicine I, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
    Gastrointest Endosc 53:784-9. 2001
    ..The diagnostic accuracy of this technique is comparable to CT, magnetic resonance imaging, positron emission tomography, and ERCP...
  16. ncbi request reprint Impact of food intake, ultrasound transducer, breathing maneuvers and body position on acoustic radiation force impulse (ARFI) elastometry of the liver
    R S Goertz
    Departement of Internal Medicine 1, University of Erlangen, 91054 Erlangen, Germany
    Ultraschall Med 33:380-5. 2012
    ..Since acoustic radiation force impulse (ARFI) elastometry is an increasingly popular method for the assessment of hepatic fibrosis and cirrhosis, we investigated factors possibly influencing hepatic elastometric measurements...
  17. ncbi request reprint Percutaneous ethanol injection and radio-frequency ablation for the treatment of nonresectable colorectal liver metastases - techniques and results
    D Becker
    Department of Medicine I, Friedrich Alexander University Erlangen Nuremberg, Krankenhausstr 12, D 91054 Erlangen, Germany
    Langenbecks Arch Surg 384:339-43. 1999
    ..The different techniques are explained and reviewed...
  18. doi request reprint Unclear focal liver lesions in contrast-enhanced ultrasonography--lessons to be learned from the DEGUM multicenter study for the characterization of liver tumors
    T Bernatik
    Department of Medicine 1, Universitiy Erlangen Nuremberg, Germany
    Ultraschall Med 31:577-81. 2010
    ..To discuss the difficulties of contrast-enhanced ultrasound (CEUS) in a large multi-center trial...
  19. doi request reprint Measurement of liver elasticity with acoustic radiation force impulse (ARFI) technology: an alternative noninvasive method for staging liver fibrosis in viral hepatitis
    R S Goertz
    Departement of Internal Medicine 1, University of Erlangen
    Ultraschall Med 31:151-5. 2010
    ..The aim of this exploratory study was to evaluate this new technique in the assessment of liver fibrosis in a cohort with chronic viral hepatitis B and C and to ascertain the most reliable hepatic segment for measurements...
  20. doi request reprint Outcome analysis of liver stiffness by ARFI (acoustic radiation force impulse) elastometry in patients with chronic viral hepatitis B and C
    R S Goertz
    Department of Internal Medicine 1, University of Erlangen, Erlangen, Germany Electronic address
    Clin Radiol 69:275-9. 2014
    ..To evaluate the association between liver stiffness measured by acoustic radiation force impulse (ARFI) elastometry and the outcome of antiviral treatment in patients with chronic viral hepatitis B and C...
  21. doi request reprint An abdominal and thyroid status with Acoustic Radiation Force Impulse Elastometry--a feasibility study: Acoustic Radiation Force Impulse Elastometry of human organs
    R S Goertz
    Department of Internal Medicine 1, University of Erlangen, Ulmenweg 18, 91054 Erlangen, Germany
    Eur J Radiol 80:e226-30. 2011
    ..The aim of this prospective feasibility study was to evaluate ARFI elastometry performed on various healthy abdominal organs and the thyroid gland...
  22. ncbi request reprint Radiofrequency ablation of hepatocellular carcinoma with a saline solution perfusion device: a pilot study
    J Hansler
    Department of Medicine I, Friedrich Alexander University, Erlangen Nuremberg, Germany
    J Vasc Interv Radiol 14:575-80. 2003
    ..This study evaluated the treatment of patients with radiofrequency ablation (RFA) with use of needle applicators perfused with isotonic saline solution...
  23. doi request reprint Eosinophilic infiltration of the liver and pancreas mimicking metastatic disease
    Rüdiger Stephan Goertz
    Departement of Internal Medicine 1, Erlangen University, Erlangen, Germany
    Z Gastroenterol 48:1138-40. 2010
    ..The histopathological work-up surprisingly identified the hepatic lesions to be eosinophilic infiltration. After a spontaneous remission we concluded an allergic reaction to a fluoroquinolone...