Johannes Schmitt

Summary

Affiliation: University of Erlangen-Nuremberg
Country: Germany

Publications

  1. ncbi Zirconia posterior fixed partial dentures: 5-year clinical results of a prospective clinical trial
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University, Erlangen, Germany
    Int J Prosthodont 25:585-9. 2012
  2. ncbi Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique--a comparative in vivo study
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University Erlangen Nuremberg, Erlangen, Germany
    Int J Prosthodont 22:193-200. 2009
  3. ncbi Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University Erlangen Nuremberg, Erlangen, Germany
    Int J Prosthodont 22:597-603. 2009
  4. ncbi Restoring severely compromised anterior teeth with zirconia crowns and feather-edged margin preparations: a 3-year follow-up of a prospective clinical trial
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University Erlangen Nuremberg, Erlangen, Germany
    Int J Prosthodont 23:107-9. 2010
  5. ncbi Five-year clinical follow-up of prefabricated precision attachments: a comparison of uni- and bilateral removable dental prostheses
    Johannes Schmitt
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Erlangen, Germany
    Quintessence Int 42:413-8. 2011
  6. ncbi Surface characteristics of zirconia-based posterior restorations: clinical and scanning electron microscopic analysis
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University of Erlangen Nuremberg, Germany
    J Can Dent Assoc 77:b31. 2011
  7. ncbi Circumferential fit assessment of CAD/CAM single crowns--a pilot investigation on a new virtual analytical protocol
    Ragai E Matta
    University Clinic Erlangen Nuremburg, Erlangen, Germany
    Quintessence Int 43:801-9. 2012
  8. doi Correlations between photogrammetric measurements of tooth mobility and the Periotest method
    Matthias Goellner
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Germany
    Acta Odontol Scand 70:27-35. 2012
  9. doi Correlations between tooth mobility and the Periotest method in periodontally involved teeth
    Matthias Goellner
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Germany
    Quintessence Int 44:307-16. 2013
  10. doi Photogrammetric measurement of initial tooth displacement under tensile force
    Matthias Goellner
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Glueckstr 11, 91054 Erlangen, Germany
    Med Eng Phys 32:883-8. 2010

Detail Information

Publications18

  1. ncbi Zirconia posterior fixed partial dentures: 5-year clinical results of a prospective clinical trial
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University, Erlangen, Germany
    Int J Prosthodont 25:585-9. 2012
    ..Major fracture of the ceramic veneer could be related to inadequate framework design or bruxism...
  2. ncbi Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique--a comparative in vivo study
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University Erlangen Nuremberg, Erlangen, Germany
    Int J Prosthodont 22:193-200. 2009
    ..This prospective clinical trial investigated the effect of different fabrication techniques on screw-joint stability in implant-retained frameworks...
  3. ncbi Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University Erlangen Nuremberg, Erlangen, Germany
    Int J Prosthodont 22:597-603. 2009
    ..The aim of this prospective clinical trial was to evaluate the reliability of three- and four-unit posterior fixed partial dentures (FPDs) with zirconia frameworks after 3 years of clinical function...
  4. ncbi Restoring severely compromised anterior teeth with zirconia crowns and feather-edged margin preparations: a 3-year follow-up of a prospective clinical trial
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University Erlangen Nuremberg, Erlangen, Germany
    Int J Prosthodont 23:107-9. 2010
    ..A survival and success rate of 100% was recorded, which suggests that the clinical method may be a reliable treatment modality for restoring severely compromised anterior teeth...
  5. ncbi Five-year clinical follow-up of prefabricated precision attachments: a comparison of uni- and bilateral removable dental prostheses
    Johannes Schmitt
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Erlangen, Germany
    Quintessence Int 42:413-8. 2011
    ..To evaluate the clinical long-term success of prefabricated precision attachments in retaining uni- or bilateral removable dental prostheses...
  6. ncbi Surface characteristics of zirconia-based posterior restorations: clinical and scanning electron microscopic analysis
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University of Erlangen Nuremberg, Germany
    J Can Dent Assoc 77:b31. 2011
    ..The aim of this prospective clinical trial was to evaluate the performance of zirconia-based all-ceramic posterior fixed partial dentures (FPDs) after 4 years of clinical use...
  7. ncbi Circumferential fit assessment of CAD/CAM single crowns--a pilot investigation on a new virtual analytical protocol
    Ragai E Matta
    University Clinic Erlangen Nuremburg, Erlangen, Germany
    Quintessence Int 43:801-9. 2012
    ..Techniques currently applied to determine the marginal accuracy of dental crown restorations yield inadequate information. This investigation aimed to test a new virtual approach for determining the precision of fit of single-crown copings...
  8. doi Correlations between photogrammetric measurements of tooth mobility and the Periotest method
    Matthias Goellner
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Germany
    Acta Odontol Scand 70:27-35. 2012
    ....
  9. doi Correlations between tooth mobility and the Periotest method in periodontally involved teeth
    Matthias Goellner
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Germany
    Quintessence Int 44:307-16. 2013
    ....
  10. doi Photogrammetric measurement of initial tooth displacement under tensile force
    Matthias Goellner
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Glueckstr 11, 91054 Erlangen, Germany
    Med Eng Phys 32:883-8. 2010
    ..The combination of a mechanical loading approach with the optoelectronic system allowed the measurement of three-dimensional tooth mobility in vivo...
  11. doi Thermal-induced residual stresses affect the lifetime of zirconia-veneer crowns
    Renan Belli
    Laboratory for Biomaterials Research, Dental Clinic 1 Operative Dentistry and Periodontology, University of Erlangen Nuremberg, Erlangen, Germany
    Dent Mater 29:181-90. 2013
    ..The purposes of this study were to investigate the effects of thermal residual stresses on the reliability and lifetime of zirconia-veneer crowns...
  12. doi Noncontact intraoral measurement of force-related tooth mobility
    Matthias Gollner
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Glueckstr 11, 91054 Erlangen, Germany
    Clin Oral Investig 14:551-7. 2010
    ..However, there were significant differences between central incisor and canine and lateral incisor and canine teeth...
  13. ncbi The effect of axial and oblique loading on the micromovement of dental implants
    Matthias Goellner
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Germany
    Int J Oral Maxillofac Implants 26:257-64. 2011
    ..To quantify implant displacement upon axial and oblique force application and compare the effects of bone quality using an in vitro experimental setup...
  14. doi Influence of attachment and bone loss on the mobility of incisors and canine teeth
    Matthias Goellner
    Dental Clinic 2, Department of Prosthodontics, University Clinic Erlangen, Glueckstr 11, 91054 Erlangen, Germany
    Acta Odontol Scand 71:656-63. 2013
    ..The purpose of this clinical study was to evaluate the correlation between tooth mobility (TM), crown-to-root ratio (CRR) and clinical attachment loss (CAL) in periodontally-compromised participants...
  15. ncbi Testing a multistage rating scale for clinical evaluation of all-ceramic surfaces
    Johannes Schmitt
    Department of Prosthodontics, Friedrich Alexander University Erlagen Nuremberg, Germany
    Int J Prosthodont 24:576-81. 2011
    ....
  16. doi An evaluation of the Periotest method as a tool for monitoring tooth mobility in dental traumatology
    Christine Berthold
    Dental Clinic 1 Operative Dentistry and Periodontology, Friedrich Alexander University, Erlangen, Germany
    Dent Traumatol 26:120-8. 2010
    ....
  17. doi Degree of conversion of luting resins around ceramic inlays in natural deep cavities: a micro-Raman spectroscopy analysis
    Ulrich Lohbauer
    Dental Clinic 1, Dental Materials Lab, Friedrich Alexander University of Erlangen, Erlangen, Germany
    Oper Dent 35:579-86. 2010
    ..Dual-cure and light-cure luting materials showed polymerization homogeneity around ceramic inlays, although dual-cure conventional resin cements tended to show an overall higher conversion...
  18. doi Prosthodontic treatment of a patient with bisphosphonate-induced osteonecrosis of the jaw using a removable dental prosthesis with a heat-polymerized resilient liner: a clinical report
    Matthias Gollner
    University Clinic Erlangen, Erlangen, Germany
    J Prosthet Dent 103:196-201. 2010
    ..Because of the recurrent incidence of BONJ, noninvasive prosthetic therapy with telescopic overdentures and a heat-polymerized resilient liner was provided. After 2 years, there were no biological or technical complications...