A Kummrow

Summary

Affiliation: Physikalisch-Technische Bundesanstalt
Country: Germany

Publications

  1. pmc Microflow cytometers with integrated hydrodynamic focusing
    Marcin Frankowski
    Physikalisch Technische Bundesanstalt, Abbestrasse 2 12, 10587 Berlin, Germany
    Sensors (Basel) 13:4674-93. 2013
  2. doi request reprint Quantitative assessment of cell viability based on flow cytometry and microscopy
    A Kummrow
    Physikalisch Technische Bundesanstalt, 10587 Berlin, Germany
    Cytometry A 83:197-204. 2013
  3. doi request reprint Microfluidic structures for flow cytometric analysis of hydrodynamically focussed blood cells fabricated by ultraprecision micromachining
    A Kummrow
    Physikalisch Technische Bundesanstalt, Abbestr 2 12, 10587, Berlin, Germany
    Lab Chip 9:972-81. 2009
  4. ncbi request reprint Evaluation of higher-order time-domain perturbation theory of photon diffusion on breast-equivalent phantoms and optical mammograms
    D Grosenick
    Physikalisch Technische Bundesanstalt, Abbestrasse 2 12, Berlin, Germany
    Phys Rev E Stat Nonlin Soft Matter Phys 76:061908. 2007

Collaborators

  • Marcin Frankowski
  • D Grosenick
  • Peter Simon
  • Martin Schmidt
  • Hülya Ragusch
  • Jörg Neukammer
  • Nicole Bock
  • Janko Theisen
  • R Macdonald
  • H Rinneberg
  • P M Schlag

Detail Information

Publications4

  1. pmc Microflow cytometers with integrated hydrodynamic focusing
    Marcin Frankowski
    Physikalisch Technische Bundesanstalt, Abbestrasse 2 12, 10587 Berlin, Germany
    Sensors (Basel) 13:4674-93. 2013
    ..The potential of the micro flow cytometer is demonstrated by detecting immunologically labeled CD3 positive and CD4 positive T-lymphocytes in blood...
  2. doi request reprint Quantitative assessment of cell viability based on flow cytometry and microscopy
    A Kummrow
    Physikalisch Technische Bundesanstalt, 10587 Berlin, Germany
    Cytometry A 83:197-204. 2013
    ..Besides monocytes, comparison of flow cytometric and microscopy viability for MACS enriched CD34-positive cells also showed consistent results...
  3. doi request reprint Microfluidic structures for flow cytometric analysis of hydrodynamically focussed blood cells fabricated by ultraprecision micromachining
    A Kummrow
    Physikalisch Technische Bundesanstalt, Abbestr 2 12, 10587, Berlin, Germany
    Lab Chip 9:972-81. 2009
    ..Furthermore, T-helper lymphocytes labelled by monoclonal antibodies were identified by measuring side scatter and fluorescence...
  4. ncbi request reprint Evaluation of higher-order time-domain perturbation theory of photon diffusion on breast-equivalent phantoms and optical mammograms
    D Grosenick
    Physikalisch Technische Bundesanstalt, Abbestrasse 2 12, Berlin, Germany
    Phys Rev E Stat Nonlin Soft Matter Phys 76:061908. 2007
    ..On average the empirical Padé approximants yield tumor absorption coefficients similar to third-order perturbation theory, yet at noticeable lower computational efforts...