E Nagel

Summary

Affiliation: Humboldt University
Country: Germany

Publications

  1. ncbi Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: comparison with dobutamine stress echocardiography
    E Nagel
    Department of Internal Medicine Cardiology, German Heart Institute and Charité Campus Virchow, Humboldt University, Berlin, Germany
    Circulation 99:763-70. 1999
  2. ncbi Optimization of realtime adaptive navigator correction for 3D magnetic resonance coronary angiography
    E Nagel
    Cardiology Internal Medicine, Charite, Campus Virchow Klinikum, Humboldt University and German Heart Institute, Berlin, Germany
    Magn Reson Med 42:408-11. 1999
  3. ncbi Functional MRI in ischemic heart disease based on detection of contraction abnormalities
    E Nagel
    Department of Internal Medicine Cardiology, Charite, Campus Virchow Klinicum, Humboldt University and German Heart Institute, 13353 Berlin, Germany
    J Magn Reson Imaging 10:411-7. 1999
  4. ncbi Dobutamine stress cardiovascular magnetic resonance at 3 Tesla
    S Kelle
    Department of Internal Medicine Cardiology, Deutsches Herzzentrum Berlin, Germany
    J Cardiovasc Magn Reson 10:44. 2008
  5. ncbi Determinants of myocardial response in CMR perfusion imaging using Gd-BOPTA (Multihance)
    Rolf Gebker
    Deutsches Herzzentrum, Berlin, Germany
    J Cardiovasc Magn Reson 7:565-72. 2005
  6. ncbi Coronary arterial stents: safety and artifacts during MR imaging
    J Hug
    Department of Internal Medicine and Cardiology, Charite, Campus Virchow Klinikum Humboldt University and German Heart Institute, Berlin, Germany
    Radiology 216:781-7. 2000
  7. ncbi Cardiovascular magnetic resonance: myocardial perfusion
    E Nagel
    Department of Internal Medicine Cardiology, German Heart Institute Berlin, Germany
    Herz 25:409-16. 2000
  8. ncbi Multi-slice dynamic imaging: complete functional cardiac MR examination within 15 seconds
    A Bornstedt
    Department of Internal Medicine Cardiology, German Heart Institute Berlin, Humboldt University, Augustenburger Platz 1, D 13353 Berlin, Germany
    J Magn Reson Imaging 14:300-5. 2001
  9. ncbi Comparison of dobutamine stress magnetic resonance, adenosine stress magnetic resonance, and adenosine stress magnetic resonance perfusion
    I Paetsch
    Department of Internal Medicine Cardiology, German Heart Institute, Berlin, Germany
    Circulation 110:835-42. 2004
  10. ncbi Magnetic resonance flow measurements in real time: comparison with a standard gradient-echo technique
    C Klein
    Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Humboldt University, Augustenburger Platz 1, D-13353 Berlin, Germany
    J Magn Reson Imaging 14:306-10. 2001

Detail Information

Publications14

  1. ncbi Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: comparison with dobutamine stress echocardiography
    E Nagel
    Department of Internal Medicine Cardiology, German Heart Institute and Charité Campus Virchow, Humboldt University, Berlin, Germany
    Circulation 99:763-70. 1999
    ..With ultrafast magnetic resonance tomography, identical stress protocols as used for echocardiography can be applied...
  2. ncbi Optimization of realtime adaptive navigator correction for 3D magnetic resonance coronary angiography
    E Nagel
    Cardiology Internal Medicine, Charite, Campus Virchow Klinikum, Humboldt University and German Heart Institute, Berlin, Germany
    Magn Reson Med 42:408-11. 1999
    ..The quality of coronary artery imaging can be improved using real-time adaptive navigator correction. Correction factors have to be adjusted for each segment of the coronary arteries and for each patient. Magn Reson Med 42:408-411, 1999...
  3. ncbi Functional MRI in ischemic heart disease based on detection of contraction abnormalities
    E Nagel
    Department of Internal Medicine Cardiology, Charite, Campus Virchow Klinicum, Humboldt University and German Heart Institute, 13353 Berlin, Germany
    J Magn Reson Imaging 10:411-7. 1999
    ..Further possibilities by the use of myocardial tagging or intravascular contrast agents are outlined...
  4. ncbi Dobutamine stress cardiovascular magnetic resonance at 3 Tesla
    S Kelle
    Department of Internal Medicine Cardiology, Deutsches Herzzentrum Berlin, Germany
    J Cardiovasc Magn Reson 10:44. 2008
    ....
  5. ncbi Determinants of myocardial response in CMR perfusion imaging using Gd-BOPTA (Multihance)
    Rolf Gebker
    Deutsches Herzzentrum, Berlin, Germany
    J Cardiovasc Magn Reson 7:565-72. 2005
    ..The purpose of this study was to evaluate the role of different sequences, dosages, and injection speeds of contrast media for semiquantitative MR-perfusion assessment...
  6. ncbi Coronary arterial stents: safety and artifacts during MR imaging
    J Hug
    Department of Internal Medicine and Cardiology, Charite, Campus Virchow Klinikum Humboldt University and German Heart Institute, Berlin, Germany
    Radiology 216:781-7. 2000
    ..To investigate the safety and imaging artifacts with different coronary arterial stents and magnetic resonance (MR) imaging sequences...
  7. ncbi Cardiovascular magnetic resonance: myocardial perfusion
    E Nagel
    Department of Internal Medicine Cardiology, German Heart Institute Berlin, Germany
    Herz 25:409-16. 2000
    ..With further improvements in analysis software magnetic resonance perfusion measurement may rapidly become a routine tool for the assessment of patients with coronary artery disease...
  8. ncbi Multi-slice dynamic imaging: complete functional cardiac MR examination within 15 seconds
    A Bornstedt
    Department of Internal Medicine Cardiology, German Heart Institute Berlin, Humboldt University, Augustenburger Platz 1, D 13353 Berlin, Germany
    J Magn Reson Imaging 14:300-5. 2001
    ..In 34 patients, left ventricular function was assessed with the new technique and a standard technique. The new technique proved to be feasible and accurate for functional cardiac examinations...
  9. ncbi Comparison of dobutamine stress magnetic resonance, adenosine stress magnetic resonance, and adenosine stress magnetic resonance perfusion
    I Paetsch
    Department of Internal Medicine Cardiology, German Heart Institute, Berlin, Germany
    Circulation 110:835-42. 2004
    ..We evaluated the diagnostic value of IWMAs during dobutamine and adenosine stress MR and adenosine MR perfusion compared with invasive coronary angiography...
  10. ncbi Magnetic resonance flow measurements in real time: comparison with a standard gradient-echo technique
    C Klein
    Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Humboldt University, Augustenburger Platz 1, D-13353 Berlin, Germany
    J Magn Reson Imaging 14:306-10. 2001
    ..Flow volume can only be determined in large vessels with sufficient accuracy, mainly due to reduced spatial resolution in smaller vessels...
  11. ncbi Primary fibrosarcoma of the liver infiltrating the right atrium of the heart
    S Kelle
    Department of Internal Medicine Cardiology, German Heart Institute, Berlin, Germany
    Int J Cardiovasc Imaging 21:655-8. 2005
    ..We report the CMR imaging characteristics in this uncommon case. Preoperative CMR proved to be useful for clinical decision making and the planning of surgery...
  12. ncbi Images in cardiovascular medicine. Progressive myocardial fibrosis in a patient with apical hypertrophic cardiomyopathy detected by cardiovascular magnetic resonance
    Rolf Gebker
    German Heart Institute Berlin, Berlin, Germany
    Circulation 114:e75-6. 2006
  13. ncbi Improved functional cardiac MR imaging using the intravascular contrast agent CLARISCAN
    I Paetsch
    Clinic of Internal Medicine/Cardiology, German Heart Institute, Humboldt University, Berlin, Germany
    Int J Cardiovasc Imaging 19:337-43. 2003
    ..The benefit in accuracy was most for patients with left ventricular ejection fraction <50%...
  14. ncbi Magnetic resonance imaging guided catheterisation for assessment of pulmonary vascular resistance: in vivo validation and clinical application in patients with pulmonary hypertension
    T Kuehne
    Department of Congenital Heart Diseases and Paediatric Cardiology, German Heart Institute, Berlin, Germany
    Heart 91:1064-9. 2005
    ..To validate in vivo a magnetic resonance imaging (MRI) method for measurement of pulmonary vascular resistance (PVR) and subsequently to apply this technique to patients with pulmonary hypertension (PHT)...