Stefan O Pfleiderer

Summary

Affiliation: Friedrich Schiller University
Country: Germany

Publications

  1. ncbi request reprint Cryotherapy of breast cancer under ultrasound guidance: initial results and limitations
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Bachstrasse 18, 07740 Jena, Germany
    Eur Radiol 12:3009-14. 2002
  2. ncbi request reprint Ultrasound-guided, percutaneous cryotherapy of small (< or = 15 mm) breast cancers
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Jena, Germany
    Invest Radiol 40:472-7. 2005
  3. ncbi request reprint Magnetic resonance-guided large-core breast biopsy inside a 1.5-T magnetic resonance scanner using an automatic system: in vitro experiments and preliminary clinical experience in four patients
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Jena, Germany
    Invest Radiol 40:458-63. 2005
  4. doi request reprint Two-year follow-up of stereotactically guided 9-G breast biopsy: a multicenter evaluation of a self-contained vacuum-assisted device
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, D 07740 Jena, Germany
    Clin Imaging 33:343-7. 2009
  5. pmc Changes in magnetic resonance mammography due to hormone replacement therapy
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University, Jena, Germany
    Breast Cancer Res 6:R232-8. 2004
  6. ncbi request reprint [Interventional MR-mammography: manipulator-assisted large core biopsy and interstitial laser therapy of tumors of the female breast]]
    Stefan O Pfleiderer
    Institut für Diagnostische und Interventionelle Radiologie, Friedrich Schiller Universitat Jena
    Z Med Phys 13:198-202. 2003
  7. ncbi request reprint A manipulator system for 14-gauge large core breast biopsies inside a high-field whole-body MR scanner
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Jena, Germany
    J Magn Reson Imaging 17:493-8. 2003
  8. ncbi request reprint Dedicated double breast coil for magnetic resonance mammography imaging, biopsy, and preoperative localization
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller Universitat Jena, Germany
    Invest Radiol 38:1-8. 2003
  9. ncbi request reprint Influence of breast lesion size and histologic findings on tumor detection rate of a computer-aided detection system
    Ansgar Malich
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Bachstr 18, 07740 Jena, Germany
    Radiology 228:851-6. 2003
  10. ncbi request reprint Effect of routine MR imaging of the brain at 1.5 T on subsequent magnetoencephalography: results in nine volunteers
    Clemens Fitzek
    Institute of Diagnostic and Interventional Radiology AB Neuroradiology MRI, Friedrich Schiller Universitat Jena, Germany
    Radiology 230:715-9. 2004

Detail Information

Publications14

  1. ncbi request reprint Cryotherapy of breast cancer under ultrasound guidance: initial results and limitations
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Bachstrasse 18, 07740 Jena, Germany
    Eur Radiol 12:3009-14. 2002
    ..Remnant DCIS components which may not be detected preinterventionally represent a challenging problem for complete ablation. In tumours larger than 15 mm two or more cryo probes should be used to achieve larger iceballs...
  2. ncbi request reprint Ultrasound-guided, percutaneous cryotherapy of small (< or = 15 mm) breast cancers
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Jena, Germany
    Invest Radiol 40:472-7. 2005
    ..The purpose of this study was to investigate the feasibility, efficacy, and safety of ultrasound-guided percutaneous cryotherapy of stage T1 breast cancers...
  3. ncbi request reprint Magnetic resonance-guided large-core breast biopsy inside a 1.5-T magnetic resonance scanner using an automatic system: in vitro experiments and preliminary clinical experience in four patients
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Jena, Germany
    Invest Radiol 40:458-63. 2005
    ..5-T whole-body scanner...
  4. doi request reprint Two-year follow-up of stereotactically guided 9-G breast biopsy: a multicenter evaluation of a self-contained vacuum-assisted device
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, D 07740 Jena, Germany
    Clin Imaging 33:343-7. 2009
    ..To evaluate the performance of a self-contained, battery-driven, vacuum-assisted breast biopsy (VABB) system for the sampling of clustered breast microcalcifications and masses under stereotactic guidance...
  5. pmc Changes in magnetic resonance mammography due to hormone replacement therapy
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University, Jena, Germany
    Breast Cancer Res 6:R232-8. 2004
    ..The aim of the present article is to investigate effects of hormone replacement therapy (HRT) on contrast medium enhancement patterns in postmenopausal patients during magnetic resonance mammography (MRM)...
  6. ncbi request reprint [Interventional MR-mammography: manipulator-assisted large core biopsy and interstitial laser therapy of tumors of the female breast]]
    Stefan O Pfleiderer
    Institut für Diagnostische und Interventionelle Radiologie, Friedrich Schiller Universitat Jena
    Z Med Phys 13:198-202. 2003
    ..GRE information is suitable for therapy monitoring during ILT within the tumor. Further studies are necessary to evaluate the accuracy of the manipulator system and the efficacy of ILT in the treatment of breast lesions...
  7. ncbi request reprint A manipulator system for 14-gauge large core breast biopsies inside a high-field whole-body MR scanner
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Jena, Germany
    J Magn Reson Imaging 17:493-8. 2003
    ..To investigate a robotic manipulator system for MR-guided breast biopsies inside a 1.5 T whole-body magnet...
  8. ncbi request reprint Dedicated double breast coil for magnetic resonance mammography imaging, biopsy, and preoperative localization
    Stefan O R Pfleiderer
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller Universitat Jena, Germany
    Invest Radiol 38:1-8. 2003
    ..The aim of this study was to compare the performance of a dedicated double breast coil for MR imaging and intervention with a standard diagnostic double breast coil...
  9. ncbi request reprint Influence of breast lesion size and histologic findings on tumor detection rate of a computer-aided detection system
    Ansgar Malich
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Bachstr 18, 07740 Jena, Germany
    Radiology 228:851-6. 2003
    ..To evaluate associations between histopathologic findings, tumor size, and detection rate of malignant mammographic findings by using a computer-aided detection (CAD) system...
  10. ncbi request reprint Effect of routine MR imaging of the brain at 1.5 T on subsequent magnetoencephalography: results in nine volunteers
    Clemens Fitzek
    Institute of Diagnostic and Interventional Radiology AB Neuroradiology MRI, Friedrich Schiller Universitat Jena, Germany
    Radiology 230:715-9. 2004
    ..To investigate whether routine magnetic resonance (MR) imaging of the brain with a whole-body 1.5-T imager affects the results of subsequent magnetoencephalography (MEG)...
  11. ncbi request reprint Images in cardiovascular medicine. A swelling of the right neck and sudden death
    Thomas Neumann
    Department of Medicine III, Friedrich Schiller University Jena, Germany
    Circulation 113:e768-9. 2006
  12. ncbi request reprint Ultrasound-guided breast biopsy using a 10-gauge self-contained vacuum-assisted device
    Tibor Vag
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Hospital Jena, Erlanger Allee 101, 07747, Jena, Germany
    Eur Radiol 17:3100-2. 2007
    ..6%. Forty-one patients were free of cancer during the follow-up period of at least 24 months. In conclusion, the self-contained VABB device is well suited for ultrasound-guided breast biopsies...
  13. doi request reprint MRI-guided interventions of the breast
    Werner A Kaiser
    Institute for Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Jena, Germany
    J Magn Reson Imaging 27:347-55. 2008
    ..In this overview the main features and initial results of these procedures are described and discussed...
  14. ncbi request reprint Are unnecessary follow-up procedures induced by computer-aided diagnosis (CAD) in mammography? Comparison of mammographic diagnosis with and without use of CAD
    Christiane Marx
    Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University of Jena, 07740 Jena, Germany
    Eur J Radiol 51:66-72. 2004
    ..To evaluate the rate of unnecessary follow-up procedures recommended by radiologists using a CAD-system...