Jens Einighammer

Summary

Country: Germany

Publications

  1. doi request reprint Customized aspheric intraocular lenses calculated with real ray tracing
    Jens Einighammer
    Centre for Ophthalmology, University Hospital, Tubingen, Germany
    J Cataract Refract Surg 35:1984-94. 2009
  2. ncbi request reprint Calculating intraocular lens geometry by real ray tracing
    Jens Einighammer
    University Eye Hospital, Tuebingen, Germany
    J Refract Surg 23:393-404. 2007
  3. doi request reprint Real ray tracing simulation versus clinical outcomes of corneal excimer laser surface ablations
    Jens Einighammer
    University Hospital Tubingen, Centre for Ophthalmology, Institute for Ophthalmic Research, Tubingen, Germany
    J Refract Surg 26:625-37. 2010
  4. doi request reprint Biometric measurements inside the model eye using a two wavelengths Fourier domain low coherence interferometer
    Sascha Birkner
    Centre for Ophthalmology, University Hospital Tubingen, Tubingen, Germany
    Biomed Tech (Berl) 56:65-71. 2011

Collaborators

Detail Information

Publications4

  1. doi request reprint Customized aspheric intraocular lenses calculated with real ray tracing
    Jens Einighammer
    Centre for Ophthalmology, University Hospital, Tubingen, Germany
    J Cataract Refract Surg 35:1984-94. 2009
    ..To calculate the exact geometry of custom intraocular lenses (IOLs) for pseudophakic eyes and theoretically predict the residual wavefront error by real ray tracing based on Snell's law...
  2. ncbi request reprint Calculating intraocular lens geometry by real ray tracing
    Jens Einighammer
    University Eye Hospital, Tuebingen, Germany
    J Refract Surg 23:393-404. 2007
    ..An implementation of real ray tracing based on Snell's law is tested by predicting the refraction of pseudophakic eyes and calculating the geometry of intraocular lenses (IOLs)...
  3. doi request reprint Real ray tracing simulation versus clinical outcomes of corneal excimer laser surface ablations
    Jens Einighammer
    University Hospital Tubingen, Centre for Ophthalmology, Institute for Ophthalmic Research, Tubingen, Germany
    J Refract Surg 26:625-37. 2010
    ..To investigate the recently reported discrepancy between theoretical expectations and clinical outcomes of corneal ablations after excimer laser corneal refractive surgery...
  4. doi request reprint Biometric measurements inside the model eye using a two wavelengths Fourier domain low coherence interferometer
    Sascha Birkner
    Centre for Ophthalmology, University Hospital Tubingen, Tubingen, Germany
    Biomed Tech (Berl) 56:65-71. 2011
    ..In addition to the fast measurement, this setup provides the possibility to adjust the laser power of both sections independently. This could help in the case of dense cataract...