Research Topics
| Damir ErkapicSummaryPublications: Erkapic D, Amberger F, Bushoven P, Ehrlich J. More Safety with more Energy – Survived electrical storm with 40J shocks. Herzschrittmacherther Elektrophysiol 2011;22(4):252-254. Wójcik M, Janin S, Neumann T, Kuniss M, Berkowitsch A, Erkapic D, Zaltsberg S, Madlener K, Wysokiński A, Hamm CW, Pitschner HF. Which standard biomarkers are useful for the evaluation of myocardial injury after pulmonary vein isolation with cryoballoon? Kardiol Pol. 2011;69(11):1151-5. Erkapic D, De Rosa S, Kelava T, Lehmann R, Fichtlscherer S, Hohnloser SH. Risk for permanent pacemaker requirement after transcatheter aortic valve implantation – A comprehensive analysis of the literature. Journal of Cardiovasc Electrophysiol 2011: Nov 3 doi:10.1111/j.1540-8167.2011.02211.x. [Epub ahead of print] Erkapic D, Duray GZ, Bauernfeind T, Rosa SD, Hohnloser SH. Insulation defects of thin high-voltage ICD leads: an underestimated problem? Journal of Cardiovasc Electrophysiol 2011;22(9):1018-22. Bauernfeind T, Erkapic D, Hohnloser SH. Innovative pharmacological approaches to managing atrial fibrillation: the importance of reducing cardiovascular hospitalizations. Innovations in cardiac rhythm management. 2011: accepted and published online January 12, 2011. Kauferstein S, Kiehne N, Erkapic D, Schmidt J, Hamm CW, Bratzke H, Pitschner HF, Kuniss M, Neumann T. A novel mutation in the cardiac ryanodine receptor gene (RyR2) in a patient with an unequivocal LQTS. Int J Cardiol 2010;146(2):249-250. Neumann T, Kuniss M, Conradi G, Janin S, Berkowitsch A, Wojcik M, Rixe J, Erkapic D, Zaltsberg S, Rolf A, Bachmann G, Dill T, Hamm CW, Pitschner HF. MEDAFI-Trial (Micro-embolization during ablation of atrial fibrillation): comparison of pulmonary vein isolation using cryoballon technique vs. radiofrequency energy. Europace 2010 Jan:13(1):37-44. Janin S, Wojcik M, Kuniss M, Berkowitsch A, Erkapic D, Zaltsberg S, Ecarnot F, Hamm CW, Pitschner HF, Neumann T. Pulmonary vein antrum isolation and terminal part of the P wave. Pacing Clin Electrophysiol. 2010 Jul; 33(7):784-789. Erkapic D, Kim W, Weber M, Möllmann H, Berkowitsch A, Zaltsberg S, Pajitnev D, Rixe J, Neumann T, Kuniss M, Sperzel J, Hamm CW, Pitschner HF. Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantation. Europace 2010; 12(8):1188-90. Neumann T, Kuniss M, Erkapic D, Zaltsberg S, Berkowitsch A, Pajitnev D, Wojcik M, Janin S, Hamm CW, Pitschner HF. Acute and long-term results of PVI at antrum using a novel high-density mapping catheter without help of 3D electro-anatomic mapping in patients with paroxysmal and chronic atrial fibrillation. J Interv Card Electrophysiol. 2010; 27(2):101-108. Neumann T, Kuniss M, Conradi G, Sperzel J, Berkowitsch A, Zaltsberg S, Wojcik M, Erkapic D, Dill T Hamm CW., Pitschner HF. Pulmonary vein stenting for the treatment of acquired severe pulmonary vein stenosis after pulmonary vein isolation: Clinical implications after long-term follow-up of 4 years. J Cardiovasc Electrophysiol. 2009 Mar;20(3):251-7. Erkapic D, Rixe J, Strunk J, Hamm CW, Dill T. Acute aortitis with spinal artery an aneurysms detected by contrast enhanced magnetic resonance imaging. Clinical Research in Cardiology 2009 Jan. 98(1):59-61. Erkapic D, Pitschner HF. Complications after ablation of supraventricular tachycardias. Herzschrittmacherther Elektrophysiol. 2008 Jun;19:33-37. Erkapic D, Neumann T, Schmitt J, Sperzel J, Berkowitsch A, Kuniss M, Hamm CW, Pitschner HF. Electrical storm in a patient with arrhythmogenic right ventricular cardiomyopathy (ARVC) and SCN5A mutation. Europace 2008; 10:884-887. Mohrs OK, Petersen SE, Erkapic D, Victor A, Schlosser T, Nowak B, Kauczor HU, Voigtländer T. Dynamic contrast-enhanced magnetic resonance imaging before and after transcatheter occlusion of a patent foramen ovale. American Journal of Roentgenology 2007; 188: 844-849. Mohrs OK, Petersen SE, Erkapic D, Rubel C, Schraeder R, Nowak B, Fach WA, Kauczor HU, Voigtlaender T. Diagnosis of patent foramen ovale using contrast-enhanced MRI - a pilot study. American Journal of Roentgenology 2005; 184:234-240. Publications
| Collaborators
|
Detail Information
Publications
Electrical storm in a patient with arrhythmogenic right ventricular cardiomyopathy and SCN5A mutationDamir Erkapic
Department of Cardiology, Kerckhoff Heart Center, Benekestr 2 8, Bad Nauheim 61231, Germany
Europace 10:884-7. 2008..The patient was treated with a combination of quinidine and verapamil and since then remained free of arrhythmias...
Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantationDamir Erkapic
Department of Cardiology, Kerckhoff Heart Center, Benekestrasse 2 8, 61231 Bad Nauheim, Germany
Europace 12:1188-90. 2010..Therefore, patients with the presence of RBBB before TAVI may be at lower risk for PM implantation using the Edwards Sapiens System...
Pulmonary vein antrum isolation and terminal part of the P waveSebastien Janin
Kerckhoff Heart Center, Department of Cardiology, Bad Nauheim, Germany
Pacing Clin Electrophysiol 33:784-9. 2010..Our purpose was to describe the modifications of the P-wave duration and Ptf after pulmonary vein antrum isolation (PVAI) in patients with paroxysmal AF...
[Complications after ablation of supraventricular tachycardias]Damir Erkapic
Department of Cardiology, Kerckhoff Heart Center, Benekestrasse 2 8, Bad Nauheim, Germany
Herzschrittmacherther Elektrophysiol 19:79-83. 2008..In experienced electrophysiological centres a complication rate of < 2% and an intention to treat mortality of < 0.1% can be expected...
Pulmonary vein stenting for the treatment of acquired severe pulmonary vein stenosis after pulmonary vein isolation: clinical implications after long-term follow-up of 4 yearsThomas Neumann
Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany
J Cardiovasc Electrophysiol 20:251-7. 2009..Whether there is additional long-term benefit from PVS stenting is uncertain. The aim of this study was the evaluation of the long-term success after PV stenting of severe stenosis...
Acute and long-term results of PVI at antrum using a novel high-density mapping catheter without help of 3D electro-anatomic mapping in patients with paroxysmal and chronic atrial fibrillationThomas Neumann
Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
J Interv Card Electrophysiol 27:101-8. 2010..We tested the effectiveness and safety of a conventional, fully endocardial electrogram-guided circumferential antrum isolation (PVI) with a novel mapping device...
MEDAFI-Trial (Micro-embolization during ablation of atrial fibrillation): comparison of pulmonary vein isolation using cryoballoon technique vs. radiofrequency energyThomas Neumann
Department of Cardiology, Kerckhoff Heart Center, Benekestrasse 2 8, 61231 Bad Nauheim, Germany
Europace 13:37-44. 2011..The purpose of this prospective pilot study was to analyse the incidence and possible impact of cryo ablation on cerebral lesions and possible differences to radiofrequency (RF) ablation during pulmonary vein isolation (PVI)...
Which standard biomarkers are useful for the evaluation of myocardial injury after pulmonary vein isolation with cryoballoon?Maciej Wojcik
Kerckhoff Heart Centre Department of Cardiology, Bad Nauheim, Germany
Kardiol Pol 69:1151-5. 2011..We applied measurements of the blood concentration of cardio-specific biomarkers as surrogates for the injured cell mass...
Limitations of biomarkers serum levels during pulmonary vein isolationMaciej Wojcik
Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany
Rev Esp Cardiol 64:127-32. 2011..We studied possible different thermal stability and usability of the proteins released by cardiac cells injured by different energy sources...
More safety with more energy: survival of electrical storm with 40-J shocksD Erkapic
Department of Cardiology, Division of Clinical Electrophysiology, J W Goethe University, Frankfurt, Germany
Herzschrittmacherther Elektrophysiol 22:252-4. 2011..Jude Medical, Sylmar, CA, USA). Using a combination of high energy and optimized fixed millisecond duration biphasic waveform shock, successful defibrillation could be achieved at 8 J below the programmed maximum energy level...
