Karine Marion-Ferey

Summary

Country: France

Publications

  1. ncbi request reprint Using an efficient biofilm detaching agent: an essential step for the improvement of endoscope reprocessing protocols
    K Marion
    Faculte de Pharmacie, EA 3090, Lyon, France
    J Hosp Infect 64:136-42. 2006
  2. ncbi request reprint Biofilm removal from silicone tubing: an assessment of the efficacy of dialysis machine decontamination procedures using an in vitro model
    K Marion-Ferey
    College of Pharmacy, Paris, France
    J Hosp Infect 53:64-71. 2003
  3. ncbi request reprint Methods for biofilm analysis on silicone tubing of dialysis machines
    K Marion-Ferey
    Faculté de Pharmacie Paris V, Laboratoire d Hydrologie, Centre de Recherche et de Contrôle des Eaux de Paris, Paris, France
    Artif Organs 27:658-64. 2003
  4. ncbi request reprint Endotoxin level measurement in hemodialysis biofilm using "the whole blood assay"
    Karine Marion-Ferey
    College of Pharmacy, Paris, France
    Artif Organs 29:475-81. 2005
  5. ncbi request reprint A new procedure allowing the complete removal and prevention of hemodialysis biofilms
    Karine Marion
    Faculte de Pharmacie, EA 3090, Laboratoire de Microbiologie, Lyon, France
    Blood Purif 23:339-48. 2005

Collaborators

  • Jeff G Leid
  • P Stoodley
  • K Marion
  • Karine Marion
  • G James
  • F N R Renaud
  • J Freney
  • J W Costerton
  • E Bergeron
  • Ehsan Delawari
  • John William Costerton
  • Jean Freney
  • Francois Renaud
  • Jules Traeger
  • Mark Pasmore

Detail Information

Publications5

  1. ncbi request reprint Using an efficient biofilm detaching agent: an essential step for the improvement of endoscope reprocessing protocols
    K Marion
    Faculte de Pharmacie, EA 3090, Lyon, France
    J Hosp Infect 64:136-42. 2006
    ..The new procedure and agents represent a new approach to biofilm control that may improve the efficacy of endoscope reprocessing, and reduce the risk of transmitting infections...
  2. ncbi request reprint Biofilm removal from silicone tubing: an assessment of the efficacy of dialysis machine decontamination procedures using an in vitro model
    K Marion-Ferey
    College of Pharmacy, Paris, France
    J Hosp Infect 53:64-71. 2003
    ..In addition, autoclaving led to a significant decrease in endotoxin level (removal of 99.99%)...
  3. ncbi request reprint Methods for biofilm analysis on silicone tubing of dialysis machines
    K Marion-Ferey
    Faculté de Pharmacie Paris V, Laboratoire d Hydrologie, Centre de Recherche et de Contrôle des Eaux de Paris, Paris, France
    Artif Organs 27:658-64. 2003
    ....
  4. ncbi request reprint Endotoxin level measurement in hemodialysis biofilm using "the whole blood assay"
    Karine Marion-Ferey
    College of Pharmacy, Paris, France
    Artif Organs 29:475-81. 2005
    ..We concluded that the LAL is necessary but insufficient to have a representative quantification of endotoxins that could be hazardous to patient health...
  5. ncbi request reprint A new procedure allowing the complete removal and prevention of hemodialysis biofilms
    Karine Marion
    Faculte de Pharmacie, EA 3090, Laboratoire de Microbiologie, Lyon, France
    Blood Purif 23:339-48. 2005
    ..The procedure led to the complete detachment of the biomass, both in vitro and in the reality situation. The aim of this procedure is to replace or complete the usual disinfection methods for medical devices...