Marc Hanna

Summary

Country: France

Publications

  1. ncbi request reprint Distributed nonlinear fiber chirped-pulse amplifier system
    Marc Hanna
    Institut d Optique, CNRS, Universite Paris Sud, Palaiseau, France
    Opt Express 17:10835-40. 2009
  2. ncbi request reprint Nonlinear compression in a rod-type fiber for high energy ultrashort pulse generation
    Igor Martial
    Institut d Optique, CNRS, Universite Paris Sud, Palaiseau, France
    Opt Express 17:11155-60. 2009
  3. ncbi request reprint Picosecond polarized supercontinuum generation controlled by intermodal four-wave mixing for fluorescence lifetime imaging microscopy
    Pierre Blandin
    Laboratoire Charles Fabry de l Institut d Optique, CNRS, University Paris Sud, Palaiseau, France
    Opt Express 16:18844-9. 2008
  4. ncbi request reprint Microjoule femtosecond fiber laser at 1.6 microm for corneal surgery applications
    Franck Morin
    Laboratoire Charles Fabry de l Institut d Optique, CNRS, , Palaiseau, France
    Opt Lett 34:1991-3. 2009
  5. doi request reprint Wavefront control of a multicore ytterbium-doped pulse fiber amplifier by digital holography
    Mathieu Paurisse
    Laboratoire Charles Fabry de l Institut d Optique, Campus Polytechnique, RD 128, 91127 Palaiseau cedex, France
    Opt Lett 35:1428-30. 2010
  6. ncbi request reprint Complete measurement of fiber modal content by wavefront analysis
    Mathieu Paurisse
    Laboratoire Charles Fabry, Institut d Optique, CNRS, Univ Paris Sud, RD128 Palaiseau Cedex, France
    Opt Express 20:4074-84. 2012
  7. doi request reprint Passive coherent beam combining of two femtosecond fiber chirped-pulse amplifiers
    Louis Daniault
    Laboratoire Charles Fabry, Institut d Optique, Universite Paris Sud, Palaiseau, France
    Opt Lett 36:4023-5. 2011
  8. doi request reprint Hybrid master oscillator power amplifier high-power narrow-linewidth nanosecond laser source at 257 nm
    Xavier Délen
    Laboratoire Charles Fabry, Institut d Optique, CNRS, Univ Paris Sud, Palaiseau, France
    Opt Lett 38:995-7. 2013

Collaborators

  • Julien Didierjean
  • Damien Sangla
  • Igor Martial
  • Patrick Georges
  • Mathieu Paurisse
  • Frederic Druon
  • Xavier Délen
  • Louis Daniault
  • Franck Morin
  • Pierre Blandin
  • Aurélien Benoit
  • Benjamin Cocquelin
  • Loïc Deyra
  • Francois Salin
  • François Balembois
  • Louis Lévèque
  • Eric Mottay
  • Dimitris N Papadopoulos
  • Yoann Zaouter
  • Philippe Leproux
  • Alessandro Tonello
  • Christelle Lesvigne
  • Vincent Couderc
  • Sandrine Lévêque-Fort

Detail Information

Publications8

  1. ncbi request reprint Distributed nonlinear fiber chirped-pulse amplifier system
    Marc Hanna
    Institut d Optique, CNRS, Universite Paris Sud, Palaiseau, France
    Opt Express 17:10835-40. 2009
    ..Our experimental implementation leads to the generation of high temporal quality 20 microJ 202 fs pulses at repetition rate of 200 kHz, a record duration at this energy level...
  2. ncbi request reprint Nonlinear compression in a rod-type fiber for high energy ultrashort pulse generation
    Igor Martial
    Institut d Optique, CNRS, Universite Paris Sud, Palaiseau, France
    Opt Express 17:11155-60. 2009
    ..The nonlinear compression setup is composed of a 5-cm-long rod-type fiber and a pair of SF10 prisms. The system was optimized to obtain good temporal quality, with a temporal Strehl ration of 86 % for the compressed 49 fs pulses...
  3. ncbi request reprint Picosecond polarized supercontinuum generation controlled by intermodal four-wave mixing for fluorescence lifetime imaging microscopy
    Pierre Blandin
    Laboratoire Charles Fabry de l Institut d Optique, CNRS, University Paris Sud, Palaiseau, France
    Opt Express 16:18844-9. 2008
    ..Using a low repetition rate ultra-stable solid state laser, a pulse train well-suited for versatile time-domain fluorescence lifetime imaging applications is obtained...
  4. ncbi request reprint Microjoule femtosecond fiber laser at 1.6 microm for corneal surgery applications
    Franck Morin
    Laboratoire Charles Fabry de l Institut d Optique, CNRS, , Palaiseau, France
    Opt Lett 34:1991-3. 2009
    ..This new compact and robust source targets medical applications such as surgery in highly scattering corneas...
  5. doi request reprint Wavefront control of a multicore ytterbium-doped pulse fiber amplifier by digital holography
    Mathieu Paurisse
    Laboratoire Charles Fabry de l Institut d Optique, Campus Polytechnique, RD 128, 91127 Palaiseau cedex, France
    Opt Lett 35:1428-30. 2010
    ..6 in all cases. The wavefront-controlled multicore fiber is used to amplify 800 ps pulses at 1064 nm at a repetition rate of 40?kHz, and a gain of 23 dB is obtained...
  6. ncbi request reprint Complete measurement of fiber modal content by wavefront analysis
    Mathieu Paurisse
    Laboratoire Charles Fabry, Institut d Optique, CNRS, Univ Paris Sud, RD128 Palaiseau Cedex, France
    Opt Express 20:4074-84. 2012
    ..This constitutes an innovative complete characterization of the beam, and might be used as a probe in deterministic active wavefront correction techniques...
  7. doi request reprint Passive coherent beam combining of two femtosecond fiber chirped-pulse amplifiers
    Louis Daniault
    Laboratoire Charles Fabry, Institut d Optique, Universite Paris Sud, Palaiseau, France
    Opt Lett 36:4023-5. 2011
    ..The behavior of this architecture in the presence of high accumulated nonlinear phase is investigated...
  8. doi request reprint Hybrid master oscillator power amplifier high-power narrow-linewidth nanosecond laser source at 257 nm
    Xavier Délen
    Laboratoire Charles Fabry, Institut d Optique, CNRS, Univ Paris Sud, Palaiseau, France
    Opt Lett 38:995-7. 2013
    ..1). At a repetition rate of 30 kHz, 106 μJ UV pulses are generated corresponding to an average power of 3.2 W...