Zhihua Ding

Summary

Affiliation: Zhejiang University
Country: China

Publications

  1. ncbi request reprint Two-dimensional scanning realized by an asymmetry fiber cantilever driven by single piezo bender actuator for optical coherence tomography
    Tong Wu
    State Key Lab of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027, PR China
    Opt Express 17:13819-29. 2009
  2. doi request reprint Transit-time analysis based on delay-encoded beam shape for velocity vector quantification by spectral-domain Doppler optical coherence tomography
    Jie Meng
    State Key Lab of Modern Optical Instrumentation, Zhejiang University, Hangzhou, P R China
    Opt Express 18:1261-70. 2010
  3. ncbi request reprint Development of a non-uniform discrete Fourier transform based high speed spectral domain optical coherence tomography system
    Kai Wang
    State Key Lab of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027, PR China
    Opt Express 17:12121-31. 2009
  4. doi request reprint Choroidal laser Doppler flowmeter with enhanced sensitivity based on a scattering plate
    Chuan Wang
    Zhejiang University, State Key Lab of Modern Optical Instrumentation, Yuquan Campus, 38 Zheda Road, Hangzhou 310027, China
    J Biomed Opt 16:047004. 2011
  5. doi request reprint Monitoring of drug and stimulation induced cerebral blood flow velocity changes in rat sensory cortex using spectral domain Doppler optical coherence tomography
    Chuan Wang
    Zhejiang University, State Key Lab of Modern Optical Instrumentation, Hangzhou 310027, China
    J Biomed Opt 16:046001. 2011
  6. doi request reprint Spectral phase based k-domain interpolation for uniform sampling in swept-source optical coherence tomography
    Tong Wu
    State Key Lab of Modern Optical Instrumentation, Zhejiang University, Hangzhou, China
    Opt Express 19:18430-9. 2011
  7. doi request reprint Full-range swept source optical coherence tomography based on carrier frequency by transmissive dispersive optical delay line
    Tong Wu
    Zhejiang University, State Key Lab of Modern Optical Instrumentation, 38 Zheda Rd, Hangzhou 310027, China
    J Biomed Opt 16:126008. 2011
  8. doi request reprint Ultralong-range phase imaging with orthogonal dispersive spectral-domain optical coherence tomography
    Chuan Wang
    State Key Lab of Modern Optical Instrumentation, Zhejiang University, Hangzhou, China
    Opt Lett 37:4555-7. 2012

Collaborators

Detail Information

Publications8

  1. ncbi request reprint Two-dimensional scanning realized by an asymmetry fiber cantilever driven by single piezo bender actuator for optical coherence tomography
    Tong Wu
    State Key Lab of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027, PR China
    Opt Express 17:13819-29. 2009
    ....
  2. doi request reprint Transit-time analysis based on delay-encoded beam shape for velocity vector quantification by spectral-domain Doppler optical coherence tomography
    Jie Meng
    State Key Lab of Modern Optical Instrumentation, Zhejiang University, Hangzhou, P R China
    Opt Express 18:1261-70. 2010
    ..The feasibility of the method is demonstrated by good agreement between the determined azimuth angles and the preset ones, and further confirmed by velocity vector measurement of flowing solution inside a capillary tube...
  3. ncbi request reprint Development of a non-uniform discrete Fourier transform based high speed spectral domain optical coherence tomography system
    Kai Wang
    State Key Lab of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027, PR China
    Opt Express 17:12121-31. 2009
    ..The comparing results confirm that reconstruction method based on NDFT indeed improves sensitivity especially at large depth while maintaining the coherence-function-limited depth resolution...
  4. doi request reprint Choroidal laser Doppler flowmeter with enhanced sensitivity based on a scattering plate
    Chuan Wang
    Zhejiang University, State Key Lab of Modern Optical Instrumentation, Yuquan Campus, 38 Zheda Road, Hangzhou 310027, China
    J Biomed Opt 16:047004. 2011
    ....
  5. doi request reprint Monitoring of drug and stimulation induced cerebral blood flow velocity changes in rat sensory cortex using spectral domain Doppler optical coherence tomography
    Chuan Wang
    Zhejiang University, State Key Lab of Modern Optical Instrumentation, Hangzhou 310027, China
    J Biomed Opt 16:046001. 2011
    ....
  6. doi request reprint Spectral phase based k-domain interpolation for uniform sampling in swept-source optical coherence tomography
    Tong Wu
    State Key Lab of Modern Optical Instrumentation, Zhejiang University, Hangzhou, China
    Opt Express 19:18430-9. 2011
    ....
  7. doi request reprint Full-range swept source optical coherence tomography based on carrier frequency by transmissive dispersive optical delay line
    Tong Wu
    Zhejiang University, State Key Lab of Modern Optical Instrumentation, 38 Zheda Rd, Hangzhou 310027, China
    J Biomed Opt 16:126008. 2011
    ..Feasibility of the proposed method for full-range imaging is validated in a custom-built SS-OCT system by in vivo imaging of a biological sample...
  8. doi request reprint Ultralong-range phase imaging with orthogonal dispersive spectral-domain optical coherence tomography
    Chuan Wang
    State Key Lab of Modern Optical Instrumentation, Zhejiang University, Hangzhou, China
    Opt Lett 37:4555-7. 2012
    ..The increased spectral sampling rate also results in a high signal-to-noise ratio of the SDOCT system. The application of the developed system is further illustrated by quantitative phase imaging of a glass plate and an optical lens...