Jie YuanSummaryCountry: China Publications
| Collaborators
|
Detail Information
Publications
Reanalysis of generalized sensitivity factors for optical-axis perturbation in nonplanar ring resonatorsJie Yuan
Department of Optoelectronic Engineering, College of Opto electric Science and Engineering, National University of Defense Technology, Changsha, Hunan 410073, China
Opt Express 21:2297-306. 2013..The analysis in this paper is important to the cavity design of non-planar ring resonators and it could be helpful to avoid the violent movement of the optical-axis to small misalignment of the mirrors in non-planar ring resonators...
Beam position controlling method for 3D optical system and its application in non-planar ring resonatorsJie Yuan
Department of Optoelectronic Engineering, College of Opto electric Science and Engineering, National University of Defense Technology, Changsha Hunan 410073, China
Opt Express 20:19563-79. 2012..This novel theoretical beam position controlling method for 3D optical system is valuable for the controlling of various kinds of 3D optical systems...
Novel coordinate system for Gaussian beam reflectionJie Yuan
Department of Optoelectronic Engineering, College of Opto electric Science and Engineering, National University of Defense Technology, Changsha Hunan 410073, China
Opt Lett 37:2082-4. 2012..This novel coordinate system is valuable for not only the designing of laser resonators but also Gaussian beam propagation analysis...
Generalized ray matrix for spherical mirror reflection and its application in square ring resonators and monolithic triaxial ring resonatorsJie Yuan
Department of Optoelectronic Engineering, College of Opto electric Science and Engineering, National University of Defense Technology, Hunan 410073, China
Opt Express 19:6762-76. 2011..This generalized ray matrix is valuable for ray analysis of various kinds of resonators. These results are important for the cavity design, cavity improvement and alignment of high accuracy and super high accuracy ring laser gyroscopes...
Precise wavelength calibration in continuous-wave cavity ringdown spectroscopy based on the HITRAN databaseZhongqi Tan
Department of Optoelectronic Engineering, College of Optoelectronic Science and Engineering, National University of Defense Technology, Changsha 410073, China
Appl Opt 48:2344-9. 2009..A wavelength precision of approximately 0.8 x 10(-3) cm-1 was obtained by comparing the HITRAN 2004 database, which was approximately four times more precise than that of the conventional method...
