Research Topics
| Xuanqin MouSummaryAffiliation: Xi'an Jiaotong University Country: China Publications
| Collaborators
|
Detail Information
Publications
Error analysis of calibration materials on dual-energy mammographyXuanqin Mou
Institute of Image Processing and Pattern Recognition, Xi an Jiaotong University Xi an, Shaanxi 710049, China
Med Image Comput Comput Assist Interv 10:596-603. 2007..The evaluation of several popular phantoms shows that it is of great importance to adopt the phantom materials approaching human breast most...
The impact of calibration phantom errors on dual-energy digital mammographyXuanqin Mou
Institute of Image Processing and Pattern Recognition, Xi an Jiaotong University, Xi an, Shaanxi 710049, People s Republic of China
Phys Med Biol 53:6321-36. 2008..Finally, an error correction method is proposed based on our findings...
Low-dose X-ray CT reconstruction via dictionary learningQiong Xu
Institute of Image Processing and Pattern Recognition, Xi an Jiaotong University, Xi an, Shaanxi 710049, China
IEEE Trans Med Imaging 31:1682-97. 2012..The results show that the proposed approach might produce better images with lower noise and more detailed structural features in our selected cases. However, there is no proof that this is true for all kinds of structures...
CT gradient image reconstruction directly from projectionsShaojie Tang
School of Automation, Xi an University of Posts and Telecommunications, Xi an, Shanxi, China
J Xray Sci Technol 19:173-98. 2011..Because the reconstructed gradient image is in terms of local operator, it have a better performance in CT image analysis and other CT applications compared to the global Calderon operator in Lambda Tomography...
Image reconstruction for hybrid true-color micro-CTQiong Xu
Institute of Image Processing and Pattern Recognition, Xi an Jiaotong University, Xi an, Shaanxi 710049, China
IEEE Trans Biomed Eng 59:1711-9. 2012..It appears harnessing that this phenomenon could potentially reduce the color detector size for a given ROI, further reducing system cost and radiation dose...
Statistical interior tomographyQiong Xu
Institute of Image Processing and Pattern Recognition, Xi an Jiaotong University, Xi an, Shaanxi 710049, China
IEEE Trans Med Imaging 30:1116-28. 2011..The results demonstrate that SIT is robust with respect to data noise and down-sampling, and has better resolution and less bias than its deterministic counterpart in the case of low count data...
A hybrid metal artifact reduction algorithm for x-ray CTYanbo Zhang
Institute of Image Processing and Pattern Recognition, Xi an Jiaotong University, Xi an, Shaanxi 710049, China
Med Phys 40:041910. 2013..This method offers a remarkable improvement of the image quality...
Projection correlation based view interpolation for cone beam CT: primary fluence restoration in scatter measurement with a moving beam stop arrayHao Yan
Institute of Image Processing and Pattern Recognition, Xi an Jiaotong University, Xi an, Shaanxi 710049, People s Republic of China
Phys Med Biol 55:6353-75. 2010..Compared with the spatial interpolation based method, the relative mean square error is reduced by a factor of 6.05-15.94 for different slices. PC-VI does well in CB redundancy mining; therefore, it has further potential in CBCT studies...
Breaking a chaos-noise-based secure communication schemeShujun Li
Department of Electronic Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR, China
Chaos 15:13703. 2005..Yet it remains to be clarified if intermittent chaos could be used for designing secure chaotic cryptosystems...
[Slice reconstruction of 3D vessel based on object-oriented quantization]Hengyong Yu
Institute of Image Processing, Xi'an Jiaotong University, Xi'an 710049
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 20:318-21. 2003..The SSGR is especially suitable for solving the problem of sparse projection and limited-views. Finally, the simulated results have proved the feasibility of the model and the validity of the algorithm...