Huijuan Zhao

Summary

Affiliation: Tianjin University
Country: China

Publications

  1. ncbi Time-resolved diffuse optical tomography and its application to in vitro and in vivo imaging
    Huijuan Zhao
    Tianjin University, State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin 3000072, China
    J Biomed Opt 12:062107. 2007
  2. ncbi Near-infrared frequency domain system and fast inverse Monte Carlo algorithm for endoscopic measurement of tubular tissue
    Huijuan Zhao
    College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
    J Xray Sci Technol 19:57-68. 2011
  3. ncbi Time-resolved diffuse optical tomographic imaging for the provision of both anatomical and functional information about biological tissue
    Huijuan Zhao
    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
    Appl Opt 44:1905-16. 2005
  4. ncbi Simultaneous fluorescence yield and lifetime tomography from time-resolved transmittances of small-animal-sized phantom
    Feng Gao
    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
    Appl Opt 49:3163-72. 2010
  5. ncbi A linear, featured-data scheme for image reconstruction in time-domain fluorescence molecular tomography
    Feng Gao
    College of Precision Instrument and Optoeletronics Engineering, Tianjin University, Tianjin 300072, China
    Opt Express 14:7109-24. 2006
  6. ncbi Time-domain fluorescence-guided diffuse optical tomography based on the third-order simplified harmonics approximation
    Wenjuan Ma
    College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
    Appl Opt 51:8656-68. 2012
  7. ncbi Combined hemoglobin and fluorescence diffuse optical tomography for breast tumor diagnosis: a pilot study on time-domain methodology
    Wei Zhang
    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
    Biomed Opt Express 4:331-48. 2013
  8. ncbi Joint derivation method for determining optical properties based on steady-state spatially resolved diffuse reflectance measurement at small source-detector separations and large reduced albedo range: theory and simulation
    Zhenzhi Shi
    Tianjin University, College of Precision Instrument and Optoelectronics Engineering, Tianjin 300072, China
    J Biomed Opt 17:067004. 2012
  9. ncbi A self-normalized, full time-resolved method for fluorescence diffuse optical tomography
    Feng Gao
    College of Precision Instrument and Optoeletronics Engineering, Tianjin University, Tianjin 300072, China
    Opt Express 16:13104-21. 2008
  10. ncbi Towards pH-sensitive imaging of small animals with photon-counting difference diffuse fluorescence tomography
    Jiao Li
    Tianjin University, College of Precision Instruments and Optoelectronics Engineering, Tianjin 300072, China
    J Biomed Opt 17:96011-1. 2012

Collaborators

Detail Information

Publications22

  1. ncbi Time-resolved diffuse optical tomography and its application to in vitro and in vivo imaging
    Huijuan Zhao
    Tianjin University, State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin 3000072, China
    J Biomed Opt 12:062107. 2007
    ..Finally, in vitro and in vivo imaging examples are illustrated for validating the capibility of TR-DOT to provide not only the anatomical but also the physiological information of the objects...
  2. ncbi Near-infrared frequency domain system and fast inverse Monte Carlo algorithm for endoscopic measurement of tubular tissue
    Huijuan Zhao
    College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
    J Xray Sci Technol 19:57-68. 2011
    ..2%. Endoscopic measurement on two tubular solid phantoms were also carried out to evaluate the system and the inversion scheme. The results demonstrated that less than 20% relative error can be achieved...
  3. ncbi Time-resolved diffuse optical tomographic imaging for the provision of both anatomical and functional information about biological tissue
    Huijuan Zhao
    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
    Appl Opt 44:1905-16. 2005
    ....
  4. ncbi Simultaneous fluorescence yield and lifetime tomography from time-resolved transmittances of small-animal-sized phantom
    Feng Gao
    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
    Appl Opt 49:3163-72. 2010
    ....
  5. ncbi A linear, featured-data scheme for image reconstruction in time-domain fluorescence molecular tomography
    Feng Gao
    College of Precision Instrument and Optoeletronics Engineering, Tianjin University, Tianjin 300072, China
    Opt Express 14:7109-24. 2006
    ....
  6. ncbi Time-domain fluorescence-guided diffuse optical tomography based on the third-order simplified harmonics approximation
    Wenjuan Ma
    College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
    Appl Opt 51:8656-68. 2012
    ....
  7. ncbi Combined hemoglobin and fluorescence diffuse optical tomography for breast tumor diagnosis: a pilot study on time-domain methodology
    Wei Zhang
    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
    Biomed Opt Express 4:331-48. 2013
    ..The results demonstrate the efficacy of improving the accuracy of hemoglobin-DOT based on a priori fluorescence localization...
  8. ncbi Joint derivation method for determining optical properties based on steady-state spatially resolved diffuse reflectance measurement at small source-detector separations and large reduced albedo range: theory and simulation
    Zhenzhi Shi
    Tianjin University, College of Precision Instrument and Optoelectronics Engineering, Tianjin 300072, China
    J Biomed Opt 17:067004. 2012
    ..The results indicate that the joint derivation method can improve the derivation accuracy and that a(') range can be determined by the steady-state spatially resolved diffuse reflectance measurement...
  9. ncbi A self-normalized, full time-resolved method for fluorescence diffuse optical tomography
    Feng Gao
    College of Precision Instrument and Optoeletronics Engineering, Tianjin University, Tianjin 300072, China
    Opt Express 16:13104-21. 2008
    ....
  10. ncbi Towards pH-sensitive imaging of small animals with photon-counting difference diffuse fluorescence tomography
    Jiao Li
    Tianjin University, College of Precision Instruments and Optoelectronics Engineering, Tianjin 300072, China
    J Biomed Opt 17:96011-1. 2012
    ....
  11. ncbi Combined domain-decomposition and matrix-decomposition scheme for large-scale diffuse optical tomography
    Fang Yang
    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
    Appl Opt 49:3111-26. 2010
    ..Also, both numerical simulations and phantom experiments show that MD-based linear inversion is superior to the row-fashioned algebraic reconstruction technique...
  12. ncbi A CT-analogous scheme for time-domain diffuse fluorescence tomography
    Feng Gao
    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China
    J Xray Sci Technol 20:91-105. 2012
    ..A pilot validation of the methodology is performed for two-dimensional scenarios using simulated and experimental data. The results demonstrated the efficacy of the proposed scheme in improving the image quality...
  13. ncbi Application of Fourier-wavelet regularized deconvolution for improving image quality of free space propagation x-ray phase contrast imaging
    Zhongxing Zhou
    School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, People s Republic of China Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, People s Republic of China
    Phys Med Biol 57:7459-79. 2012
    ....
  14. ncbi A phantom-based calibration method for digital x-ray tomosynthesis
    Hui Miao
    Tianjin University, Tianjin, China
    J Xray Sci Technol 20:17-29. 2012
    ..The purpose of this study was to develop a phantom-based experimental calibration method to minimize the reconstruction artifacts for the geometric misalignments of the digital tomosynthesis prototype...
  15. ncbi Hybrid diffusion-P3 equation in N-layered turbid media: steady-state domain
    Zhenzhi Shi
    Tianjin University, State Key Laboratory of Precision Measuring Technology and Instrument, Tianjin 300072, China
    J Biomed Opt 16:105002. 2011
    ..In conclusion, the model of the hybrid diffusion-P3 equation can replace the diffusion equation for modeling light propagation in the N-layered turbid media for a wide range of absorption coefficients...
  16. ncbi Three-dimensional scheme for time-domain fluorescence molecular tomography based on Laplace transforms with noise-robust factors
    Limin Zhang
    College of Precision Instrument and Optoeletronics Engineering, Tianjin University, Tianjin 300072, China
    Opt Express 16:7214-23. 2008
    ....
  17. ncbi Techniques to improve the accuracy of noise power spectrum measurements in digital x-ray imaging based on background trends removal
    Zhongxing Zhou
    School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
    Med Phys 38:1600-10. 2011
    ..The purpose of this study was to investigate an appropriate background detrending technique to improve the accuracy of NPS estimation for digital x-ray systems...
  18. ncbi Optical tomographic mapping of cerebral haemodynamics by means of time-domain detection: methodology and phantom validation
    Feng Gao
    National Institute of Advanced Industrial Science and Technology, 1 2 Namiki, Tsukuba, Ibaraki, 305 8564, Japan
    Phys Med Biol 49:1055-78. 2004
    ..The methodology is also validated by experiments using a solid layered phantom...
  19. ncbi Imaging of in vitro chicken leg using time-resolved near-infrared optical tomography
    Huijuan Zhao
    National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan
    Phys Med Biol 47:1979-93. 2002
    ....
  20. ncbi Maps of optical differential pathlength factor of human adult forehead, somatosensory motor and occipital regions at multi-wavelengths in NIR
    Huijuan Zhao
    Institute for Human Science and Biomedical Engineering, National Institute of Advanced Industrial Science and Technology AIST, Tsukuba, Ibaraki, Japan
    Phys Med Biol 47:2075-93. 2002
    ..The DPF data will be useful for quantitative monitoring of the haemodynamic changes occurring in adult heads...
  21. ncbi Semi-three-dimensional algorithm for time-resolved diffuse optical tomography by use of the generalized pulse spectrum technique
    Feng Gao
    Institute for Human Science and Biomedical Engineering, National Institute of Advanced Industrial Science and Technology, 1 2 Namiki, Tsukuba, Ibaraki 305 8564, Japan
    Appl Opt 41:7346-58. 2002
    ..We demonstrate our algorithm by comparing it with the calibrated 2-D reconstruction that is in widespread use as a shortcut to 3-D imaging and proving that the semi-3-D algorithm outperforms the calibrated 2-D algorithm...
  22. ncbi Improvement of image quality in diffuse optical tomography by use of full time-resolved data
    Feng Gao
    Institute for Human Science and Biomedical Engineering, National Institute of Advanced Industrial Science and Technology, Tsukuba, lbaraki, Japan
    Appl Opt 41:778-91. 2002
    ....