Shinsuke Tokuda

Summary

Affiliation: Clear Water Bay
Country: China

Publications

  1. ncbi request reprint An amperometric bi-enzyme sensor for determination of formate using cofactor regeneration
    Karen K W Mak
    Sino German Nano Analytical Lab SiGNAL and Department of Chemistry, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
    Biosens Bioelectron 18:1095-100. 2003
  2. ncbi request reprint Application of cyanide hydrolase from Klebsiella sp. in a biosensor system for the detection of low-level cyanide
    Karen K W Mak
    Biosensors and Bioelectronics Laboratory, Department of Chemistry, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
    Appl Microbiol Biotechnol 67:631-6. 2005
  3. ncbi request reprint Cyanide fishing and cyanide detection in coral reef fish using chemical tests and biosensors
    Karen K W Mak
    Department of Chemistry, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
    Biosens Bioelectron 20:2581-93. 2005

Collaborators

Detail Information

Publications3

  1. ncbi request reprint An amperometric bi-enzyme sensor for determination of formate using cofactor regeneration
    Karen K W Mak
    Sino German Nano Analytical Lab SiGNAL and Department of Chemistry, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
    Biosens Bioelectron 18:1095-100. 2003
    ..98 x 10(-7) M for formate (S/N=3), with the response time of 4 min. The working stability is limited to 7 days due to the inactivation of the enzymes. Only sodium salicylate was needed in milli-molar amounts...
  2. ncbi request reprint Application of cyanide hydrolase from Klebsiella sp. in a biosensor system for the detection of low-level cyanide
    Karen K W Mak
    Biosensors and Bioelectronics Laboratory, Department of Chemistry, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
    Appl Microbiol Biotechnol 67:631-6. 2005
    ..3 micromol l(-1) cyanide. The linear range of the calibration curve was between 30 micromol l(-1) and 300 micromol l(-1) cyanide...
  3. ncbi request reprint Cyanide fishing and cyanide detection in coral reef fish using chemical tests and biosensors
    Karen K W Mak
    Department of Chemistry, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
    Biosens Bioelectron 20:2581-93. 2005
    ..A novel approach to detect cyanide in marine fish tissues is briefly discussed...