Shuo Tang

Summary

Affiliation: University of British Columbia
Country: Canada

Publications

  1. doi request reprint Multimodal optical imaging with multiphoton microscopy and optical coherence tomography
    Shuo Tang
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada
    J Biophotonics 5:396-403. 2012
  2. pmc Design and implementation of fiber-based multiphoton endoscopy with microelectromechanical systems scanning
    Shuo Tang
    University of British Columbia, Department of Electrical and Computer Engineering, Vancouver, BC V6T1Z4, Canada
    J Biomed Opt 14:034005. 2009
  3. doi request reprint Multiscale multimodal imaging with multiphoton microscopy and optical coherence tomography
    Shuo Tang
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Opt Lett 36:4800-2. 2011
  4. doi request reprint Imaging-guided two-photon excitation-emission-matrix measurements of human skin tissues
    Yingqiu Yu
    Imaging Unit, Integrative Oncology Department, British Columbia Cancer Agency Research Center, 675 West 10th Avenue, Vancouver, BC, V5Z 1L3, Canada
    J Biomed Opt 17:077004. 2012
  5. doi request reprint Perfectly registered multiphoton and reflectance confocal video rate imaging of in vivo human skin
    Hequn Wang
    Imaging Unit Integrative Oncology Department, British Columbia Cancer Agency Research Centre, Vancouver, BC, Canada
    J Biophotonics 6:305-9. 2013
  6. pmc Characterizing refractive index and thickness of biological tissues using combined multiphoton microscopy and optical coherence tomography
    Yifeng Zhou
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
    Biomed Opt Express 4:38-50. 2013
  7. doi request reprint Calibrating the measurement of wavelength-dependent second harmonic generation from biological tissues with a BaB₂O₄ crystal
    Mengzhe Shen
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    J Biomed Opt 18:031109. 2013
  8. doi request reprint Selection of convolution kernel in non-uniform fast Fourier transform for Fourier domain optical coherence tomography
    Kenny K H Chan
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Opt Express 19:26891-904. 2011
  9. doi request reprint In vivo video rate multiphoton microscopy imaging of human skin
    Anthony M D Lee
    Integrative Oncology Department Imaging Unit, British Columbia Cancer Agency Research Centre, Vancouver, British Columbia V5Z 1L3, Canada
    Opt Lett 36:2865-7. 2011
  10. pmc Imaging subcellular scattering contrast by using combined optical coherence and multiphoton microscopy
    Shuo Tang
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver V6T 1Z4, Canada
    Opt Lett 32:503-5. 2007

Collaborators

Detail Information

Publications10

  1. doi request reprint Multimodal optical imaging with multiphoton microscopy and optical coherence tomography
    Shuo Tang
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada
    J Biophotonics 5:396-403. 2012
    ..Multi-scale MPM/OCT can change FOV but need both low and high NA objectives. For future development, the two types of MPM/OCT can be further integrated to achieve both functions on a single system...
  2. pmc Design and implementation of fiber-based multiphoton endoscopy with microelectromechanical systems scanning
    Shuo Tang
    University of British Columbia, Department of Electrical and Computer Engineering, Vancouver, BC V6T1Z4, Canada
    J Biomed Opt 14:034005. 2009
    ..A two-lens configuration with a collimation and a focusing lens provides the optimum imaging performance and packaging flexibility. The endoscope is applied to image fluorescent microspheres and bovine knee joint cartilage...
  3. doi request reprint Multiscale multimodal imaging with multiphoton microscopy and optical coherence tomography
    Shuo Tang
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Opt Lett 36:4800-2. 2011
    ..The multiscale MPM/OCT system shows the potential of a rapid coarse scan to search for abnormal regions and the subsequent fine zoom-in imaging for diagnosis...
  4. doi request reprint Imaging-guided two-photon excitation-emission-matrix measurements of human skin tissues
    Yingqiu Yu
    Imaging Unit, Integrative Oncology Department, British Columbia Cancer Agency Research Center, 675 West 10th Avenue, Vancouver, BC, V5Z 1L3, Canada
    J Biomed Opt 17:077004. 2012
    ..These results suggest that the imaging guided TPF EEM spectroscopy provides useful information for the development of multiphoton clinical devices for skin disease diagnosis...
  5. doi request reprint Perfectly registered multiphoton and reflectance confocal video rate imaging of in vivo human skin
    Hequn Wang
    Imaging Unit Integrative Oncology Department, British Columbia Cancer Agency Research Centre, Vancouver, BC, Canada
    J Biophotonics 6:305-9. 2013
    ..The demonstrated fast imaging speed and multimodal imaging capabilities of this MPM/RCM instrument are essential features for future clinical application of this technique...
  6. pmc Characterizing refractive index and thickness of biological tissues using combined multiphoton microscopy and optical coherence tomography
    Yifeng Zhou
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
    Biomed Opt Express 4:38-50. 2013
    ..The combined MPM/OCT technique is shown to be able to distinguish tissue layers through biochemically specific contrasts and measure RI and thickness of tissue layers at different depths...
  7. doi request reprint Calibrating the measurement of wavelength-dependent second harmonic generation from biological tissues with a BaB₂O₄ crystal
    Mengzhe Shen
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    J Biomed Opt 18:031109. 2013
    ..We also investigate the wavelength dependence of a 10-μm thick mouse tendon tissue in both forward and backward directions. It is found that SHG of mouse tendon tissue decreases monotonically for excitation from 750 to 950 nm...
  8. doi request reprint Selection of convolution kernel in non-uniform fast Fourier transform for Fourier domain optical coherence tomography
    Kenny K H Chan
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Opt Express 19:26891-904. 2011
    ..Finally, the algorithm is used to reconstruct in-vivo images of a human finger at a camera limited 50k A-line/s...
  9. doi request reprint In vivo video rate multiphoton microscopy imaging of human skin
    Anthony M D Lee
    Integrative Oncology Department Imaging Unit, British Columbia Cancer Agency Research Centre, Vancouver, British Columbia V5Z 1L3, Canada
    Opt Lett 36:2865-7. 2011
    ..Second harmonic generation and two-photon fluorescence images and videos acquired at optimized wavelengths are presented showing cellular and tissue structures from the skin surface down to the reticular dermis...
  10. pmc Imaging subcellular scattering contrast by using combined optical coherence and multiphoton microscopy
    Shuo Tang
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver V6T 1Z4, Canada
    Opt Lett 32:503-5. 2007
    ..There is little contribution to scattering from regions inside the nuclear core. These results confirm that light scattering signals from specific subcellular structures can be visualized by using coherent reflectance geometry...