Ilker Hacihaliloglu

Summary

Affiliation: University of British Columbia
Country: Canada

Publications

  1. ncbi request reprint Statistical shape model to 3D ultrasound registration for spine interventions using enhanced local phase features
    Ilker Hacihaliloghlu
    Department of Electrical Engineering, University of British Columbia, Vancouver, B C, Canada
    Med Image Comput Comput Assist Interv 16:361-8. 2013
  2. doi request reprint Non-iterative partial view 3D ultrasound to CT registration in ultrasound-guided computer-assisted orthopedic surgery
    Ilker Hacihaliloglu
    Department of Orthopaedic Surgery, Centre for Hip Health and Mobility, University of British Columbia, 7 F, 2635 Laurel Street, Vancouver, BC, V5Z 1M9, Canada
    Int J Comput Assist Radiol Surg 8:157-68. 2013
  3. ncbi request reprint Bone segmentation and fracture detection in ultrasound using 3D local phase features
    Ilker Hacihaliloglu
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Med Image Comput Comput Assist Interv 11:287-95. 2008
  4. ncbi request reprint 3D ultrasound-CT registration in orthopaedic trauma using GMM registration with optimized particle simulation-based data reduction
    Ilker Hacihaliloglu
    Departments of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
    Med Image Comput Comput Assist Interv 15:82-9. 2012
  5. doi request reprint Automatic bone localization and fracture detection from volumetric ultrasound images using 3-D local phase features
    Ilker Hacihaliloglu
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Ultrasound Med Biol 38:128-44. 2012
  6. doi request reprint Automatic adaptive parameterization in local phase feature-based bone segmentation in ultrasound
    Ilker Hacihaliloglu
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Ultrasound Med Biol 37:1689-703. 2011
  7. ncbi request reprint Towards real-time 3D US to CT bone image registration using phase and curvature feature based GMM matching
    Anna Brounstein
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, B C, Canada
    Med Image Comput Comput Assist Interv 14:235-42. 2011
  8. doi request reprint Bone surface localization in ultrasound using image phase-based features
    Ilker Hacihaliloglu
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Ultrasound Med Biol 35:1475-87. 2009

Collaborators

Detail Information

Publications8

  1. ncbi request reprint Statistical shape model to 3D ultrasound registration for spine interventions using enhanced local phase features
    Ilker Hacihaliloghlu
    Department of Electrical Engineering, University of British Columbia, Vancouver, B C, Canada
    Med Image Comput Comput Assist Interv 16:361-8. 2013
    ..5 mm. The improvement achieved in registration accuracy using the new features was also significant (p < 0.05) compared to state of the art local phase image processing methods...
  2. doi request reprint Non-iterative partial view 3D ultrasound to CT registration in ultrasound-guided computer-assisted orthopedic surgery
    Ilker Hacihaliloglu
    Department of Orthopaedic Surgery, Centre for Hip Health and Mobility, University of British Columbia, 7 F, 2635 Laurel Street, Vancouver, BC, V5Z 1M9, Canada
    Int J Comput Assist Radiol Surg 8:157-68. 2013
    ..Furthermore, typically, only partial views of the three-dimensional (3D) bone anatomy are visible in US data, and registration would only converge if a good estimation of the initial alignment between the US and CT datasets is known...
  3. ncbi request reprint Bone segmentation and fracture detection in ultrasound using 3D local phase features
    Ilker Hacihaliloglu
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Med Image Comput Comput Assist Interv 11:287-95. 2008
    ..62 mm and mean errors in estimating fracture displacements below 0.65 mm, which will likely be of strong clinical utility...
  4. ncbi request reprint 3D ultrasound-CT registration in orthopaedic trauma using GMM registration with optimized particle simulation-based data reduction
    Ilker Hacihaliloglu
    Departments of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
    Med Image Comput Comput Assist Interv 15:82-9. 2012
    ..We show an 89% average improvement in target registration error over the recent GMM registration based method...
  5. doi request reprint Automatic bone localization and fracture detection from volumetric ultrasound images using 3-D local phase features
    Ilker Hacihaliloglu
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Ultrasound Med Biol 38:128-44. 2012
    ..6 mm. The results show that the proposed method is successful even for situations when the bone surface response is weak due to shadowing from muscle and fascia interfaces above the bone, which is a situation where the 2-D method fails...
  6. doi request reprint Automatic adaptive parameterization in local phase feature-based bone segmentation in ultrasound
    Ilker Hacihaliloglu
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Ultrasound Med Biol 37:1689-703. 2011
    ..Results from a pilot in vivo study on human subjects, scanned in the operating room, show similar improvements...
  7. ncbi request reprint Towards real-time 3D US to CT bone image registration using phase and curvature feature based GMM matching
    Anna Brounstein
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, B C, Canada
    Med Image Comput Comput Assist Interv 14:235-42. 2011
    ..We present quantitative and qualitative results on both phantom and clinical pelvis data and show a mean registration time of 2.11 s with a mean accuracy of 0.49 mm...
  8. doi request reprint Bone surface localization in ultrasound using image phase-based features
    Ilker Hacihaliloglu
    Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
    Ultrasound Med Biol 35:1475-87. 2009
    ..40 mm. Furthermore, small gaps between bone fragments can be detected with fracture displacement mean error below 0.33 mm for vertical misalignments, and 0.47 mm for horizontal misalignments...