S K Boyd

Summary

Affiliation: University of Calgary
Country: Canada

Publications

  1. ncbi request reprint Instantaneous moment arm determination of the cat knee
    S K Boyd
    Human Performance Laboratory, University of Calgary, Canada
    J Biomech 31:279-83. 1998
  2. ncbi request reprint Early morphometric and anisotropic change in periarticular cancellous bone in a model of experimental knee osteoarthritis quantified using microcomputed tomography
    S K Boyd
    McCaig Centre for Joint Injury and Arthritis Research, University of Calgary, Calgary, Canada
    Clin Biomech (Bristol, Avon) 15:624-31. 2000
  3. ncbi request reprint Early regional adaptation of periarticular bone mineral density after anterior cruciate ligament injury
    S K Boyd
    Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, Canada T2P 1N4
    J Appl Physiol (1985) 89:2359-64. 2000
  4. ncbi request reprint Precise measurement of cat patellofemoral joint surface geometry with multistation digital photogrammetry
    J L Ronsky
    Department of Mechanical Engineering, University of Calgary, Canada
    J Biomech Eng 121:196-205. 1999
  5. doi request reprint Women with previous fragility fractures can be classified based on bone microarchitecture and finite element analysis measured with HR-pQCT
    K K Nishiyama
    Schulich School of Engineering, University of Calgary, Calgary, Canada
    Osteoporos Int 24:1733-40. 2013
  6. ncbi request reprint Joint surface modeling with thin-plate splines
    S K Boyd
    Department of Mechanical Engineering, University of Calgary, Canada
    J Biomech Eng 121:525-32. 1999
  7. doi request reprint Signs of irreversible architectural changes occur early in the development of experimental osteoporosis as assessed by in vivo micro-CT
    G M Campbell
    Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive, N W, Calgary, Alberta, T2N 1N4, Canada
    Osteoporos Int 19:1409-19. 2008
  8. ncbi request reprint Long-term periarticular bone adaptation in a feline knee injury model for post-traumatic experimental osteoarthritis
    S K Boyd
    Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Canada
    Osteoarthritis Cartilage 13:235-42. 2005
  9. doi request reprint Changes in trabecular and cortical bone microarchitecture at peripheral sites associated with 18 months of teriparatide therapy in postmenopausal women with osteoporosis
    H M Macdonald
    Department of Mechanical and Manufacturing Engineering, Schulich School of Engineering, University of Calgary, 2500 University Drive, N W, Calgary, AB, T2N 1N4, Canada
    Osteoporos Int 22:357-62. 2011
  10. ncbi request reprint Increased bone mass in male and female mice following tamoxifen administration
    L M Starnes
    Department of Biochemistry and Molecular Biology, The Alberta Bone and Joint Health Institute, University of Calgary, Calgary, Alberta, Canada
    Genesis 45:229-35. 2007

Collaborators

Detail Information

Publications12

  1. ncbi request reprint Instantaneous moment arm determination of the cat knee
    S K Boyd
    Human Performance Laboratory, University of Calgary, Canada
    J Biomech 31:279-83. 1998
    ..The in situ experiment demonstrated the ability to use the IHA technique without compromising the integrity of the knee joint so that further histological, morphological, or topological information could be investigated...
  2. ncbi request reprint Early morphometric and anisotropic change in periarticular cancellous bone in a model of experimental knee osteoarthritis quantified using microcomputed tomography
    S K Boyd
    McCaig Centre for Joint Injury and Arthritis Research, University of Calgary, Calgary, Canada
    Clin Biomech (Bristol, Avon) 15:624-31. 2000
    ..To quantify early stage microstructural changes of periarticular cancellous bone in a canine anterior cruciate ligament transection model for experimental osteoarthritis...
  3. ncbi request reprint Early regional adaptation of periarticular bone mineral density after anterior cruciate ligament injury
    S K Boyd
    Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, Canada T2P 1N4
    J Appl Physiol (1985) 89:2359-64. 2000
    ..Early decreases in BMD in the injured knee may be related to altered loading and kinematics in the knee and may be an important link in the pathogenesis of posttraumatic osteoarthritis...
  4. ncbi request reprint Precise measurement of cat patellofemoral joint surface geometry with multistation digital photogrammetry
    J L Ronsky
    Department of Mechanical Engineering, University of Calgary, Canada
    J Biomech Eng 121:196-205. 1999
    ..3 microns for subchondral bone and 17.9 microns for cartilage. The difference in measurement precision for bone and cartilage primarily reflects differences in the translucent properties of the surfaces...
  5. doi request reprint Women with previous fragility fractures can be classified based on bone microarchitecture and finite element analysis measured with HR-pQCT
    K K Nishiyama
    Schulich School of Engineering, University of Calgary, Calgary, Canada
    Osteoporos Int 24:1733-40. 2013
    ..The HR-pQCT measurements outperformed dual energy x-ray absorptiometry (DXA) at classifying forearm fractures and fractures at other skeletal sites...
  6. ncbi request reprint Joint surface modeling with thin-plate splines
    S K Boyd
    Department of Mechanical Engineering, University of Calgary, Canada
    J Biomech Eng 121:525-32. 1999
    ..A detailed algorithm is presented for implementation of the TPS...
  7. doi request reprint Signs of irreversible architectural changes occur early in the development of experimental osteoporosis as assessed by in vivo micro-CT
    G M Campbell
    Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive, N W, Calgary, Alberta, T2N 1N4, Canada
    Osteoporos Int 19:1409-19. 2008
    ..This highlights that topological changes to the structure occur early in this experimental model of osteoporosis...
  8. ncbi request reprint Long-term periarticular bone adaptation in a feline knee injury model for post-traumatic experimental osteoarthritis
    S K Boyd
    Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Canada
    Osteoarthritis Cartilage 13:235-42. 2005
    ..These periarticular bone changes are related to the health of all knee tissues including articular cartilage degeneration and may be a key component of osteoarthritic development...
  9. doi request reprint Changes in trabecular and cortical bone microarchitecture at peripheral sites associated with 18 months of teriparatide therapy in postmenopausal women with osteoporosis
    H M Macdonald
    Department of Mechanical and Manufacturing Engineering, Schulich School of Engineering, University of Calgary, 2500 University Drive, N W, Calgary, AB, T2N 1N4, Canada
    Osteoporos Int 22:357-62. 2011
    ..Despite treatment-associated declines in total and cortical BMD, trabecular thinning and reduced trabecular bone volume, bone strength did not change significantly from baseline...
  10. ncbi request reprint Increased bone mass in male and female mice following tamoxifen administration
    L M Starnes
    Department of Biochemistry and Molecular Biology, The Alberta Bone and Joint Health Institute, University of Calgary, Calgary, Alberta, Canada
    Genesis 45:229-35. 2007
    ....
  11. doi request reprint Bone micro-architecture, estimated bone strength, and the muscle-bone interaction in elite athletes: an HR-pQCT study
    J D Schipilow
    Schulich School of Engineering, University of Calgary, Canada
    Bone 56:281-9. 2013
    ..This data suggests that impact loading in sporting activity is highly associated with bone quality. Longitudinal and interventional studies are required to further clarify the muscle-bone interaction...
  12. ncbi request reprint Determination of vertebral endplate deformation under load using micro-computed tomography
    P A Hulme
    MEM Research Center, University of Bern, Stauffacherstrasse 78, CH 3014, Bern, Switzerland
    J Biomech 41:78-85. 2008
    ..Using this micro-CT based method, the effect of interbody implants, grafts, disc replacement strategies, and surgical procedures such as nucleotomy and vertebral cement augmentation on endplate mechanical behaviour can be ascertained...