Kyle M GilbertSummaryAffiliation: Robarts Research Institute Country: Canada Publications
| Collaborators
|
Detail Information
Publications
A conformal transceive array for 7 T neuroimagingKyle M Gilbert
Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada
Magn Reson Med 67:1487-96. 2012..High cortical signal-to-noise ratio and parallel imaging performance make the conformal coil ideal for the study of high temporal and/or spatial cortical architecture and function...
A cradle-shaped gradient coil to expand the clear-bore width of an animal MRI scannerK M Gilbert
Centre for Functional and Metabolic Mapping, Robarts Research Institute, The University of Western Ontario, PO Box 5015, 100 Perth Drive, London, Ontario, N6A 5K8, Canada
Phys Med Biol 55:497-514. 2010..Eddy currents were measured along each gradient axis. A large 65.2 (Hz mT(-1) m) B(0) eddy current was produced by the y-axis, suggesting potential limitations of single-sided gradient coils...
Transmit/receive radiofrequency coil with individually shielded elementsKyle M Gilbert
Centre for Functional and Metabolic Mapping, Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada
Magn Reson Med 64:1640-51. 2010..The greatest asset of this decoupling method lies in its versatility: transceive coils can be created with elements of arbitrary shape, size, location, and resonant frequency to produce three-dimensional conformal arrays...
A radiofrequency coil to facilitate B₁⁺ shimming and parallel imaging acceleration in three dimensions at 7 TKyle M Gilbert
Robarts Research Institute, The University of Western Ontario, London, ON, Canada
NMR Biomed 24:815-23. 2011....
Slice-by-slice B1+ shimming at 7 TAndrew T Curtis
Centre for Functional and Metabolic Mapping, Robarts Research Institute, Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
Magn Reson Med 68:1109-16. 2012..9±2.6% and 26.2±10.4%, respectively, at the expense of a 135±8% increase in global SAR. Robust multislice-shim solutions are demonstrated that can be quickly calculated, applied in real time, and reliably improve on volume coil modes...
Design of field-cycled magnetic resonance systems for small animal imagingK M Gilbert
Department of Physics and Astronomy, The University of Western Ontario, London, Ontario, N6A 3K7, Canada
Phys Med Biol 51:2825-41. 2006..5 T and readout magnetic fields corresponding to a proton Larmor frequency of 5 MHz. The specifications of the final design are presented along with its expected electromagnetic and thermal performance...
First image from a combined positron emission tomography and field-cycled MRI systemGeron A Bindseil
Department of Physics and Astronomy, The University of Western Ontario, London, Ontario, Canada
Magn Reson Med 66:301-5. 2011....
Evaluation of a positron emission tomography (PET)-compatible field-cycled MRI (FCMRI) scannerKyle M Gilbert
Department of Physics and Astronomy, The University of Western Ontario, London, Ontario, Canada
Magn Reson Med 62:1017-25. 2009..Preliminary MR images demonstrated the potential of the FCMRI scanner and the efficacy of integrating a PET system...
