Yasser Fawzy

Summary

Country: Canada

Publications

  1. ncbi In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection
    Yasser S Fawzy
    Perceptronix Medical Inc, Suite 400, 555 West 8th Avenue, Vancouver, British Columbia V5Z 1C6, Canada
    J Biomed Opt 11:044003. 2006
  2. doi Intrinsic fluorescence spectroscopy for endoscopic detection and localization of the endobronchial cancerous lesions
    Yasser Fawzy
    Perceptronix Medical, Incorporated, Suite 400, 555 W 8th Avenue, Vancouver, BC V5Z 1C6 Canada
    J Biomed Opt 13:064022. 2008
  3. ncbi Determination of scattering volume fraction and particle size distribution in the superficial layer of a turbid medium by using diffuse reflectance spectroscopy
    Yasser S Fawzy
    Perceptronix Medical Incorporated, Vancouver, British Columbia, Canada
    Appl Opt 45:3902-12. 2006

Collaborators

Detail Information

Publications3

  1. ncbi In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection
    Yasser S Fawzy
    Perceptronix Medical Inc, Suite 400, 555 West 8th Avenue, Vancouver, British Columbia V5Z 1C6, Canada
    J Biomed Opt 11:044003. 2006
    ..The results also showed that the malignant lung lesions can be differentiated from normal tissue/benign lesions with both diagnostic sensitivity and specificity of better than 80%...
  2. doi Intrinsic fluorescence spectroscopy for endoscopic detection and localization of the endobronchial cancerous lesions
    Yasser Fawzy
    Perceptronix Medical, Incorporated, Suite 400, 555 W 8th Avenue, Vancouver, BC V5Z 1C6 Canada
    J Biomed Opt 13:064022. 2008
    ..This may indicate that intrinsic fluorescence analysis could be used to improve the diagnostic specificity of fluorescence spectroscopy and imaging...
  3. ncbi Determination of scattering volume fraction and particle size distribution in the superficial layer of a turbid medium by using diffuse reflectance spectroscopy
    Yasser S Fawzy
    Perceptronix Medical Incorporated, Vancouver, British Columbia, Canada
    Appl Opt 45:3902-12. 2006
    ..These results suggest the potential of using this method for measuring the volume fraction changes of tissue microstructure scatterers and applications in the detection of cancerous related morphological and structural changes...