Pierre M Lane

Summary

Affiliation: British Columbia
Country: Canada

Publications

  1. ncbi request reprint Simple device for the direct visualization of oral-cavity tissue fluorescence
    Pierre M Lane
    British Columbia Cancer Research Center, Cancer Imaging Department, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3, Canada
    J Biomed Opt 11:024006. 2006
  2. doi request reprint Confocal fluorescence microendoscopy of bronchial epithelium
    Pierre M Lane
    British Columbia Cancer Research Center, Cancer Imaging Department, 675 West 10th Avenue, Vancouver, BC V5Z 1 L3, Canada
    J Biomed Opt 14:024008. 2009
  3. doi request reprint Terminal reflections in fiber-optic image guides
    Pierre M Lane
    Cancer Imaging Department, British Columbia Cancer Research Center, 675 West 10 Avenue, Vancouver, BC V5V 1L3, Canada
    Appl Opt 48:5802-10. 2009
  4. pmc Reflection-contrast limit of fiber-optic image guides
    Pierre M Lane
    British Columbia Cancer Agency, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3, Canada
    J Biomed Opt 14:064028. 2009

Detail Information

Publications4

  1. ncbi request reprint Simple device for the direct visualization of oral-cavity tissue fluorescence
    Pierre M Lane
    British Columbia Cancer Research Center, Cancer Imaging Department, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3, Canada
    J Biomed Opt 11:024006. 2006
    ..We envisage this device as a suitable adjunct for oral cancer screening, biopsy guidance, and margin delineation...
  2. doi request reprint Confocal fluorescence microendoscopy of bronchial epithelium
    Pierre M Lane
    British Columbia Cancer Research Center, Cancer Imaging Department, 675 West 10th Avenue, Vancouver, BC V5Z 1 L3, Canada
    J Biomed Opt 14:024008. 2009
    ..However, further improvements in the miniature objective lens are required to provide sufficient axial resolution for accurate classification of preneoplastic lesions...
  3. doi request reprint Terminal reflections in fiber-optic image guides
    Pierre M Lane
    Cancer Imaging Department, British Columbia Cancer Research Center, 675 West 10 Avenue, Vancouver, BC V5V 1L3, Canada
    Appl Opt 48:5802-10. 2009
    ..An achievable minimum backreflection of -36 dB was measured at 635 nm in a commercial image guide with 30,000 fibers...
  4. pmc Reflection-contrast limit of fiber-optic image guides
    Pierre M Lane
    British Columbia Cancer Agency, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3, Canada
    J Biomed Opt 14:064028. 2009
    ..We also presented a simple model that can be used to predict signal-to-background ratio in a fiber-optic confocal reflectance endomicroscope for biologically relevant tissues and contrast agents that cover a wide range of reflectivity...