Carlos Nelson Elias

Summary

Country: Brazil

Publications

  1. ncbi Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants
    Carlos Nelson Elias
    Biomaterials Laboratory, Instituto Militar de Engenharia, Rio de Janeiro, RJ, Brazil
    J Mech Behav Biomed Mater 16:169-80. 2012
  2. ncbi Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque
    Carlos Nelson Elias
    Biomaterials Laboratory, Instituto Militar de Engenharia, Pr Gen Tiburcio 80, 22290 270 Rio de Janeiro, RJ, Brazil
    J Mech Behav Biomed Mater 1:234-42. 2008
  3. ncbi Improving osseointegration of dental implants
    Carlos Nelson Elias
    Instituto Militar de Engenharia, Biomaterials Laboratory, Pr Gen Tiburcio 80, 22290 270 Rio de Janeiro, RJ, Brazil
    Expert Rev Med Devices 7:241-56. 2010
  4. ncbi The effects of superficial roughness and design on the primary stability of dental implants
    Mychelle Vianna Dos Santos
    Biomaterials Laboratory, Instituto Militar de Engenharia, Rio de Janeiro, RJ, Brazil
    Clin Implant Dent Relat Res 13:215-23. 2011
  5. ncbi Influence of thermal or chemical degradation on the frictional force of an experimental coated NiTi wire
    Ana Maria Bezerra Bandeira
    Program of Metallurgical and Materials Engineering, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
    Angle Orthod 81:484-9. 2011
  6. ncbi Sequential bone healing of immediately loaded mini-implants
    Glaucio Serra
    University of California at San Diego Engineering Military Institute, Rio de Janeiro, Brazil
    Am J Orthod Dentofacial Orthop 134:44-52. 2008
  7. ncbi Force-deflection properties of initial orthodontic archwires
    Catia Cardoso Abdo Quintão
    Department of Orthodontics, State University of Rio de Janeiro, Rio de Janeiro, Brazil
    World J Orthod 10:29-32. 2009
  8. ncbi Influence of curvature location along an artificial canal on cyclic fatigue of a rotary nickel-titanium endodontic instrument
    Hélio Pereira Lopes
    Department of Endodontics, Faculty of Dentistry, Estacio de Sa University, Rio de Janeiro, Brazil
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod 111:792-6. 2011
  9. ncbi Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires
    Dayanne Lopes da Silva
    PhD Student, Department of Orthodontics, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
    Am J Orthod Dentofacial Orthop 143:S85-91. 2013
  10. ncbi Ceramic surface polishing techniques after removal of orthodontic adhesive
    Adriana de Alcântara Cury-Saramago
    Department of Orthodontics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
    Angle Orthod 79:790-5. 2009

Collaborators

  • Glaucio Serra
  • Luiz Meirelles
  • Clarice Nishio
  • Dayanne Lopes da Silva
  • Mychelle Vianna Dos Santos
  • Ana Maria Bezerra Bandeira
  • Hélio Pereira Lopes
  • Antonio Carlos de Oliveira Ruellas
  • Catia Cardoso Abdo Quintão
  • Adriana de Alcântara Cury-Saramago
  • Eduardo Franzotti Sant' Anna
  • Claudia Trindade Mattos
  • Marcia Pereira Alves dos Santos
  • Jose Henrique Cavalcanti Lima
  • Edson Jorge Lima Moreira
  • Norbi Rodrigues Correia
  • Gino Pulitini
  • Wanderson Miguel Maia Chiesa
  • Núbia Carvalho de Souza Navegante
  • Bianca Esther Cabral Chiesa
  • Marysilva Ferreira da Costa
  • Luciane M Menezes
  • Julio Pedra e Cal-Neto
  • Priscila Rocha Coimbra
  • Antonio de Moraes Izquierdo
  • Eduardo Franzotti Sant'anna

Detail Information

Publications11

  1. ncbi Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants
    Carlos Nelson Elias
    Biomaterials Laboratory, Instituto Militar de Engenharia, Rio de Janeiro, RJ, Brazil
    J Mech Behav Biomed Mater 16:169-80. 2012
    ..The highest insertion torque was that of anodized tapered implants inserted into undersized sites. Finally, the primary stability of dental implants is highly dependent on implant design, surgical technique and substrate type...
  2. ncbi Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque
    Carlos Nelson Elias
    Biomaterials Laboratory, Instituto Militar de Engenharia, Pr Gen Tiburcio 80, 22290 270 Rio de Janeiro, RJ, Brazil
    J Mech Behav Biomed Mater 1:234-42. 2008
    ....
  3. ncbi Improving osseointegration of dental implants
    Carlos Nelson Elias
    Instituto Militar de Engenharia, Biomaterials Laboratory, Pr Gen Tiburcio 80, 22290 270 Rio de Janeiro, RJ, Brazil
    Expert Rev Med Devices 7:241-56. 2010
    ..This review focuses on different types of dental implant surfaces and the influence of surface characteristics on osseointegration...
  4. ncbi The effects of superficial roughness and design on the primary stability of dental implants
    Mychelle Vianna Dos Santos
    Biomaterials Laboratory, Instituto Militar de Engenharia, Rio de Janeiro, RJ, Brazil
    Clin Implant Dent Relat Res 13:215-23. 2011
    ..Primary implant stability has been used as an indicator for future osseointegration and whether an immediate/early loading protocol should be applied. Implant stability is the key to clinical success...
  5. ncbi Influence of thermal or chemical degradation on the frictional force of an experimental coated NiTi wire
    Ana Maria Bezerra Bandeira
    Program of Metallurgical and Materials Engineering, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
    Angle Orthod 81:484-9. 2011
    ..The null hypothesis is that there will be no difference among the wires as to friction force...
  6. ncbi Sequential bone healing of immediately loaded mini-implants
    Glaucio Serra
    University of California at San Diego Engineering Military Institute, Rio de Janeiro, Brazil
    Am J Orthod Dentofacial Orthop 134:44-52. 2008
    ..The purpose of this study was to analyze interfacial healing 1, 4, and 12 weeks after the placment of titanium mini-implants in New Zealand rabbits by removal torque test (RTT) and scanning electron microscopy (SEM)...
  7. ncbi Force-deflection properties of initial orthodontic archwires
    Catia Cardoso Abdo Quintão
    Department of Orthodontics, State University of Rio de Janeiro, Rio de Janeiro, Brazil
    World J Orthod 10:29-32. 2009
    ..The study tested four wire designs: multistranded stainless steel, conventional stainless steel, superelastic nickel-titanium, and thermoactivated nickel-titanium archwires...
  8. ncbi Influence of curvature location along an artificial canal on cyclic fatigue of a rotary nickel-titanium endodontic instrument
    Hélio Pereira Lopes
    Department of Endodontics, Faculty of Dentistry, Estacio de Sa University, Rio de Janeiro, Brazil
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod 111:792-6. 2011
    ....
  9. ncbi Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires
    Dayanne Lopes da Silva
    PhD Student, Department of Orthodontics, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
    Am J Orthod Dentofacial Orthop 143:S85-91. 2013
    ....
  10. ncbi Ceramic surface polishing techniques after removal of orthodontic adhesive
    Adriana de Alcântara Cury-Saramago
    Department of Orthodontics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
    Angle Orthod 79:790-5. 2009
    ..Verify the in vitro effectiveness of different porcelain surface polishing systems used after orthodontic debonding...
  11. ncbi In vitro evaluation of frictional forces between archwires and ceramic brackets
    Clarice Nishio
    Department of Orthodontics, Universidade Federal Fluminense, Niteroi, RJ, Brazil
    Am J Orthod Dentofacial Orthop 125:56-64. 2004
    ..The frictional force values were directly proportional to the angulation increase between the bracket and the wire...