Rodrigo Peixoto Campos

Summary

Country: Brazil

Publications

  1. doi Accuracy of physical examination and intra-access pressure in the detection of stenosis in hemodialysis arteriovenous fistula
    Rodrigo Peixoto Campos
    Division of Interventional and Critical Care Nephrology, Hospital Universitario Evangelico de Curitiba, Curitiba, Brazil
    Semin Dial 21:269-73. 2008
  2. pmc Minocycline-EDTA lock solution prevents catheter-related bacteremia in hemodialysis
    Rodrigo Peixoto Campos
    Center for Health and Biological Sciences, Pontificia Universidade Catolica do Parana, Curitiba PR, Brazil
    J Am Soc Nephrol 22:1939-45. 2011
  3. ncbi Percutaneous and surgical insertion of peritoneal catheter in patients starting in chronic dialysis therapy: a comparative study
    Domingos Candiota Chula
    Centro de Nefrologia Intervencionista da Fundação Pró Renal de Curitiba, Curitiba, Brazil Departamento de Clínica Médica, Universidade Federal do Parana, Parana, Brazil
    Semin Dial 27:E32-7. 2014
  4. doi Complications of the peritoneal access and their management
    Rodrigo Peixoto Campos
    Department of Medicine, Evangelic School of Medicine, Curitiba, Brazil
    Contrib Nephrol 163:183-97. 2009

Collaborators

  • Domingos Candiota Chula
  • Marcelo Mazza do Nascimento
  • Miguel Carlos Riella
  • Márcia Tokunaga de Alcântara

Detail Information

Publications4

  1. doi Accuracy of physical examination and intra-access pressure in the detection of stenosis in hemodialysis arteriovenous fistula
    Rodrigo Peixoto Campos
    Division of Interventional and Critical Care Nephrology, Hospital Universitario Evangelico de Curitiba, Curitiba, Brazil
    Semin Dial 21:269-73. 2008
    ..The accuracy for PE and IAP was 88% and 71%, respectively. PE proved to be an accurate method for the diagnosis of stenosis and should be part of all surveillance protocols of stenosis detection in AVF...
  2. pmc Minocycline-EDTA lock solution prevents catheter-related bacteremia in hemodialysis
    Rodrigo Peixoto Campos
    Center for Health and Biological Sciences, Pontificia Universidade Catolica do Parana, Curitiba PR, Brazil
    J Am Soc Nephrol 22:1939-45. 2011
    ..005). In conclusion, a minocycline-EDTA catheter lock solution is effective in the prevention of catheter-related bacteremia in hemodialysis patients...
  3. ncbi Percutaneous and surgical insertion of peritoneal catheter in patients starting in chronic dialysis therapy: a comparative study
    Domingos Candiota Chula
    Centro de Nefrologia Intervencionista da Fundação Pró Renal de Curitiba, Curitiba, Brazil Departamento de Clínica Médica, Universidade Federal do Parana, Parana, Brazil
    Semin Dial 27:E32-7. 2014
    ..88, p = 0.95). The outcome of percutaneous implanted catheters, which were inserted by a trained nephrologist, did not demonstrate to be inferior as compared with the traditional surgical approach...
  4. doi Complications of the peritoneal access and their management
    Rodrigo Peixoto Campos
    Department of Medicine, Evangelic School of Medicine, Curitiba, Brazil
    Contrib Nephrol 163:183-97. 2009
    ..Pre-operative evaluation and identification of potential risk factors are essential to prevent them...