K J Batenburg

Summary

Affiliation: University of Antwerp
Country: Belgium

Publications

  1. doi request reprint Optimal threshold selection for tomogram segmentation by projection distance minimization
    K J Batenburg
    University of Antwerp, IBBT Vision Lab, Universiteitsplein 1, B 2610 Wilrijk Antwerp, Belgium
    IEEE Trans Med Imaging 28:676-86. 2009
  2. doi request reprint Measuring porosity at the nanoscale by quantitative electron tomography
    E Biermans
    EMAT, University of Antwerp, Groenenborgerlaan 171, B 2020 Antwerp, Belgium
    Nano Lett 10:5014-9. 2010
  3. doi request reprint Advanced reconstruction algorithms for electron tomography: from comparison to combination
    B Goris
    EMAT, University of Antwerp, Groenenborgerlaan 171, B 2020 Antwerp, Belgium
    Ultramicroscopy 127:40-7. 2013
  4. ncbi request reprint Accurate segmentation of dense nanoparticles by partially discrete electron tomography
    T Roelandts
    IBBT Vision Lab University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium
    Ultramicroscopy 114:96-105. 2012
  5. doi request reprint Performance improvements for iterative electron tomography reconstruction using graphics processing units (GPUs)
    W J Palenstijn
    IBBT Vision Lab, University of Antwerp Universiteitsplein 1, B 2610, Wilrijk, Belgium
    J Struct Biol 176:250-3. 2011
  6. doi request reprint Iterative correction of beam hardening artifacts in CT
    G Van Gompel
    IBBT Vision Lab, Universiteit Antwerpen, 2610 Antwerp, Belgium
    Med Phys 38:S36. 2011

Collaborators

Detail Information

Publications6

  1. doi request reprint Optimal threshold selection for tomogram segmentation by projection distance minimization
    K J Batenburg
    University of Antwerp, IBBT Vision Lab, Universiteitsplein 1, B 2610 Wilrijk Antwerp, Belgium
    IEEE Trans Med Imaging 28:676-86. 2009
    ..Simulation experiments applied to various phantom images show that our proposed method obtains superior results compared to established histogram-based methods...
  2. doi request reprint Measuring porosity at the nanoscale by quantitative electron tomography
    E Biermans
    EMAT, University of Antwerp, Groenenborgerlaan 171, B 2020 Antwerp, Belgium
    Nano Lett 10:5014-9. 2010
    ..It provides accurate 3D quantitative information, regardless the presence of a missing wedge. As an example, we applied our approach to nanovoids in La2Zr2O7 thin films...
  3. doi request reprint Advanced reconstruction algorithms for electron tomography: from comparison to combination
    B Goris
    EMAT, University of Antwerp, Groenenborgerlaan 171, B 2020 Antwerp, Belgium
    Ultramicroscopy 127:40-7. 2013
    ..This approach results in a tomographic reconstruction of which the segmentation is carried out in an objective manner...
  4. ncbi request reprint Accurate segmentation of dense nanoparticles by partially discrete electron tomography
    T Roelandts
    IBBT Vision Lab University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium
    Ultramicroscopy 114:96-105. 2012
    ..For both experimental and simulated data, it is shown that PDART yields significantly more accurate segmentations than those obtained by optimal global thresholding of the SIRT reconstruction...
  5. doi request reprint Performance improvements for iterative electron tomography reconstruction using graphics processing units (GPUs)
    W J Palenstijn
    IBBT Vision Lab, University of Antwerp Universiteitsplein 1, B 2610, Wilrijk, Belgium
    J Struct Biol 176:250-3. 2011
    ..By carefully considering memory access locality when dividing the workload among blocks of threads, the GPU's cache is used more efficiently, making more effective use of the available memory bandwidth...
  6. doi request reprint Iterative correction of beam hardening artifacts in CT
    G Van Gompel
    IBBT Vision Lab, Universiteit Antwerpen, 2610 Antwerp, Belgium
    Med Phys 38:S36. 2011
    ..To reduce beam hardening artifacts in CT in case of an unknown x-ray spectrum and unknown material properties...