F Maes

Summary

Affiliation: Katholieke Universiteit Leuven
Country: Belgium

Publications

  1. ncbi request reprint Multimodality image registration by maximization of mutual information
    F Maes
    Laboratory for Medical Imaging Research, Katholieke Universiteit Leuven, Universitair Ziekenhuis Gasthuisberg, Belgium
    IEEE Trans Med Imaging 16:187-98. 1997
  2. ncbi request reprint Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information
    F Maes
    Katholieke Universiteit Leuven, Department of Electrical Engineering ESAT PSI, Heverlee, Belgium
    Med Image Anal 3:373-86. 1999
  3. doi request reprint Image quality vs radiation dose of four cone beam computed tomography scanners
    M Loubele
    ESAT PSI, Katholieke Universiteit Leuven, Belgium
    Dentomaxillofac Radiol 37:309-18. 2008
  4. ncbi request reprint Model-based segmentation using graph representations
    D Seghers
    Katholieke Universiteit Leuven, Faculty of Medicine, Medical Image Computing Radiology ESAT PSI, University Hospital Gasthuisberg, Herestraat 49, B 3000 Leuven, Belgium
    Med Image Comput Comput Assist Interv 11:393-400. 2008
  5. ncbi request reprint Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements
    M Loubele
    Medical Image Computing ESAT PSI, Faculty of Engineering, Katholieke Universiteit Leuven, Leuven, Belgium
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105:512-8. 2008
  6. ncbi request reprint Temporal subtraction of thorax CR images using a statistical deformation model
    D Loeckx
    Medical Image Computing Radiology ESAT PSI, Faculties of Medicine and Engineering, University Hospital Gasthuisberg, Herestraat 49, B 3000 Leuven, Belgium
    IEEE Trans Med Imaging 22:1490-504. 2003
  7. doi request reprint Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applications
    M Loubele
    ESAT PSI, KULeuven, Medical Imaging Center, Herestraat 49 bus 7003, 3000 Leuven, Belgium
    Radiat Prot Dosimetry 129:222-6. 2008
  8. ncbi request reprint Predicting soft tissue deformations for a maxillofacial surgery planning system: from computational strategies to a complete clinical validation
    W Mollemans
    Medical Image Computing Radiology ESAT PSI, Faculties of Medicine and Engineering, University Hospital Gasthuisberg, Herestraat 49, B 3000 Leuven, Belgium
    Med Image Anal 11:282-301. 2007
  9. ncbi request reprint Automated segmentation of multiple sclerosis lesions by model outlier detection
    K Van Leemput
    Medical Image Computing, Faculties of Medicine and Engineering, University Hospital Gasthuisberg, Leuven, Belgium
    IEEE Trans Med Imaging 20:677-88. 2001
  10. ncbi request reprint Quantifying myocardial deformation throughout the cardiac cycle: a comparison of ultrasound strain rate, grey-scale M-mode and magnetic resonance imaging
    L Herbots
    Department of Cardiology, University Hospital Gasthuisberg, Katholieke Universiteit Leuven, Leuven, Belgium
    Ultrasound Med Biol 30:591-8. 2004

Collaborators

Detail Information

Publications14

  1. ncbi request reprint Multimodality image registration by maximization of mutual information
    F Maes
    Laboratory for Medical Imaging Research, Katholieke Universiteit Leuven, Universitair Ziekenhuis Gasthuisberg, Belgium
    IEEE Trans Med Imaging 16:187-98. 1997
    ....
  2. ncbi request reprint Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information
    F Maes
    Katholieke Universiteit Leuven, Department of Electrical Engineering ESAT PSI, Heverlee, Belgium
    Med Image Anal 3:373-86. 1999
    ..Large data sets such as 256(2) x 128 MR and 512(2) x 48 CT images can be registered with subvoxel precision in <5 min CPU time on current workstations...
  3. doi request reprint Image quality vs radiation dose of four cone beam computed tomography scanners
    M Loubele
    ESAT PSI, Katholieke Universiteit Leuven, Belgium
    Dentomaxillofac Radiol 37:309-18. 2008
    ..To evaluate image quality by examining segmentation accuracy and assess radiation dose for cone beam CT (CBCT) scanners...
  4. ncbi request reprint Model-based segmentation using graph representations
    D Seghers
    Katholieke Universiteit Leuven, Faculty of Medicine, Medical Image Computing Radiology ESAT PSI, University Hospital Gasthuisberg, Herestraat 49, B 3000 Leuven, Belgium
    Med Image Comput Comput Assist Interv 11:393-400. 2008
    ..The algorithm is validated for hand bone segmentation from RX datasets and for 3D liver segmentation from contrast enhanced CT images...
  5. ncbi request reprint Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements
    M Loubele
    Medical Image Computing ESAT PSI, Faculty of Engineering, Katholieke Universiteit Leuven, Leuven, Belgium
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105:512-8. 2008
    ..To compare the accuracy of cone-beam computerized tomography (CBCT) and multislice CT (MSCT) for linear jaw bone measurements...
  6. ncbi request reprint Temporal subtraction of thorax CR images using a statistical deformation model
    D Loeckx
    Medical Image Computing Radiology ESAT PSI, Faculties of Medicine and Engineering, University Hospital Gasthuisberg, Herestraat 49, B 3000 Leuven, Belgium
    IEEE Trans Med Imaging 22:1490-504. 2003
    ..Registration quality is assessed on a second set of validation images by a human expert rating each subtraction image on screen. In 85% of the cases, the registration is subjectively rated to be adequate for clinical use...
  7. doi request reprint Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applications
    M Loubele
    ESAT PSI, KULeuven, Medical Imaging Center, Herestraat 49 bus 7003, 3000 Leuven, Belgium
    Radiat Prot Dosimetry 129:222-6. 2008
    ..Bone was segmented with sub-millimetre accuracyin all scanners...
  8. ncbi request reprint Predicting soft tissue deformations for a maxillofacial surgery planning system: from computational strategies to a complete clinical validation
    W Mollemans
    Medical Image Computing Radiology ESAT PSI, Faculties of Medicine and Engineering, University Hospital Gasthuisberg, Herestraat 49, B 3000 Leuven, Belgium
    Med Image Anal 11:282-301. 2007
    ..Therefore, the usage of a maxillofacial soft tissue prediction system is relevant and suitable for daily clinical practice...
  9. ncbi request reprint Automated segmentation of multiple sclerosis lesions by model outlier detection
    K Van Leemput
    Medical Image Computing, Faculties of Medicine and Engineering, University Hospital Gasthuisberg, Leuven, Belgium
    IEEE Trans Med Imaging 20:677-88. 2001
    ..When the degree of spatial correspondence between segmentations is taken into account, considerable disagreement is found, both between expert segmentations, and between expert and automatic measurements...
  10. ncbi request reprint Quantifying myocardial deformation throughout the cardiac cycle: a comparison of ultrasound strain rate, grey-scale M-mode and magnetic resonance imaging
    L Herbots
    Department of Cardiology, University Hospital Gasthuisberg, Katholieke Universiteit Leuven, Leuven, Belgium
    Ultrasound Med Biol 30:591-8. 2004
    ..42 and 0.32), but remained within acceptable limits for clinical decision making. Myocardial deformation measurements using SRI correlated well with MRI and US M-mode measurements throughout the complete cardiac cycle...
  11. ncbi request reprint Radiation dose vs. image quality for low-dose CT protocols of the head for maxillofacial surgery and oral implant planning
    M Loubele
    Medical Image Computing ESAT PSI, Hospital Gasthuisberg, Katholieke Universiteit Leuven, Herestraat 49, B 3000 Leuven, Belgium
    Radiat Prot Dosimetry 117:211-6. 2005
    ..Tests on ESP and skull phantom indicated that the accuracy of the measurements on low-dose CT is acceptable for image-based planning of maxillofacial and oral implant surgery, reducing the dose by a factor of 8...
  12. ncbi request reprint Accuracy of magnetic resonance imaging for measuring fetal sheep lungs and other organs
    J Jani
    Centre for Surgical Technologies, Faculty of Medicine, Katholieke Universiteit Leuven, Belgium
    Ultrasound Obstet Gynecol 25:270-6. 2005
    ..So far, the accuracy and precision of fetMRI for volumetry of either the normal or hypoplastic developing lung has not been formally studied...
  13. ncbi request reprint Interobserver variations in gross tumor volume delineation of brain tumors on computed tomography and impact of magnetic resonance imaging
    C Weltens
    Department of Radiotherapy, University Hospital Gasthuisberg, Leuven, Belgium
    Radiother Oncol 60:49-59. 2001
    ..GTVs delineated on MRI+CT are larger than on CT alone, but some volumes are delineated on CT and not on MRI. Therefore, a combination of the two image modalities is recommended for brain tumor delineation for treatment planning...
  14. ncbi request reprint Magnetization transfer analysis of cartilage repair tissue: a preliminary study
    F Palmieri
    Department of Radiology, University Federico II, Via Pansini 5, 80131 Naples, Italy
    Skeletal Radiol 35:903-8. 2006
    ..To evaluate the magnetization transfer ratio (MTR) after two different cartilage repair procedures, and to compare these data with the MTR of normal cartilage...