QT interval analysis on ambulatory electrocardiogram recordings: a selective beat averaging approachF Badilini
Hopital Lariboisiere, Service de cardiologie, Paris, France
Med Biol Eng Comput 37:71-9. 1999
..197 +/- 0.07 and 0.139 +/- 0.03, p < 0.01). The range of circadian QT variation at identical heart rate was approximately 20 ms for both males and females...
The ISCE ECG genome pilot challenge: a 2004 progress reportPaul Kligfield
Division of Cardiology, Weill Medical College of Cornell University, New York, NY 10021, USA
J Electrocardiol 37:144-8. 2004
..The present report documents the early implementation of that goal...
Heart rate variability in passive tilt test: comparative evaluation of autoregressive and FFT spectral analysesF Badilini
Department of Cardiology, Hopital Lariboisiere, Paris, France
Pacing Clin Electrophysiol 21:1122-32. 1998
..Nevertheless, dynamic trends provided by the two approaches are consistent. Normalization is necessary to evidence the LF increase during tilt...
Frequency-domain heart rate variability in 24-hour Holter recordings: role of spectral method to assess circadian patterns and pharmacological autonomic modulationF Badilini
Department of Cardiology, Hopital Lariboisiere, Paris, France
J Electrocardiol 33:147-57. 2000
..The low-frequency component of heart rate variability cannot be considered a reliable direct marker of sympathetic activity in long-term ambulatory ECG recording...
ECGScan: a method for conversion of paper electrocardiographic printouts to digital electrocardiographic filesFabio Badilini
AMPS LLC, New York, NY 10025, USA
J Electrocardiol 38:310-8. 2005
..At the same time, the new requirements justify the need for tools to convert existing paper ECG records into digital format, particularly for retrospective studies...
Influence of atropine on fractal and complexity measures of heart rate variabilityJuha S Perkiomaki
Cardiology Unit, University of Rochester Medical Center, 601 Elmwood Avenue, Box 653, Rochester, NY 14642, USA
Ann Noninvasive Electrocardiol 7:326-31. 2002
..CONCLUSIONS: Vagal tone has an important influence on the values of the short-term scaling exponent alpha(1). However, vagal modulation is not a major determinant of the values of ApEn...
Implications of methodological differences in digital electrocardiogram interval measurementFabio Badilini
AMPS-LLC, New York, NY 10025, USA
J Electrocardiol 39:S152-6. 2006
..A better understanding of the implications from different measurement methodologies will facilitate more informed choice of the appropriate method for ECG interval measurement on clinical trials...
Quantitative assessment of ST segment elevation in Brugada patientsFabrice Extramiana
Lariboisiere University Hospital, Paris, France
Heart Rhythm 3:1175-81. 2006
..This pattern is variable and can be concealed, but the magnitude and the cause of ST segment fluctuations have been poorly investigated...
Quantitative performance of E-Scribe warehouse in detecting quality issues with digital annotated ECG data from healthy subjectsNenad Sarapa
Daiichi Sankyo Pharma Development, Edison, New Jersey, USA
J Clin Pharmacol 48:538-46. 2008
..The E-Scribe Warehouse showed satisfactory performance in detecting electrocardiogram quality issues that may impair reliability of QTc assessment in clinical trials in healthy subjects...