Arno Martin

Summary

Affiliation: Landeskrankenhaus Feldkirch
Country: Austria

Publications

  1. ncbi request reprint [Relevance of wound drainage in total knee arthroplasty--a prospective comparative study]
    A Martin
    Lehrkrankenhaus der Universität Innsbruck, Landeskrankenhaus Feldkirch, Orthopädie und orthopädische Chirurgie, Feldkirch, Austria
    Z Orthop Ihre Grenzgeb 142:46-50. 2004
  2. ncbi request reprint [CT-based and CT-free navigation in total knee arthroplasty--a prospective comparative study with respects to clinical and radiological results]
    A Martin
    Lehrkrankenhaus der Universität Innsbruck, Landeskrankenhaus Feldkirch, Orthopädie und orthopädische Chirurgie, Feldkirch, Osterreich
    Z Orthop Ihre Grenzgeb 143:323-8. 2005
  3. ncbi request reprint Two-year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties
    Arno Martin
    Department of Orthopedic Surgery, Academic Teaching Hospital, Medical University of Innsbruck, Feldkirch, Austria
    Clin Orthop Relat Res 449:275-82. 2006
  4. pmc Transfusion of autologous blood from reinfusion systems in total knee arthroplasty
    A Martin
    Academic Teaching Hospital, Department of Orthopedic Surgery, Medical University of Innsbruck, Feldkirch, Austria
    Int Orthop 30:541-4. 2006
  5. doi request reprint Accuracy of side-cutting implantation instruments for total knee arthroplasty
    Arno Martin
    Department of Orthopedic Surgery, University Teaching Hospital, Medical University of Innsbruck, Carinagasse 47, 6800 Feldkirch, Austria
    Knee Surg Sports Traumatol Arthrosc 17:374-81. 2009
  6. doi request reprint [Post-traumatic osteoarthritis of the knee: special indication for navigated TKA]
    A Martin
    Academic Teaching Hospital, Department of Orthopedic Surgery, Medical University of Innsbruck, Carinagasse 47, A 6800 Feldkirch, Osterreich
    Unfallchirurg 111:754-8. 2008
  7. doi request reprint Comparison of two minimally invasive implantation instrument-sets for total knee arthroplasty
    Arno Martin
    Department of Orthopedic Surgery, University Teaching Hospital, Medical University of Innsbruck, Carinagasse 47, 6800 Feldkirch, Austria
    Knee Surg Sports Traumatol Arthrosc 18:359-66. 2010
  8. ncbi request reprint Imageless navigation for TKA increases implantation accuracy
    Arno Martin
    Department of Orthopedic Surgery, Academic Teaching Hospital, Medical University of Innsbruck, Feldkirch, Austria
    Clin Orthop Relat Res 460:178-84. 2007
  9. pmc Does single use of an autologous transfusion system in TKA reduce the need for allogenic blood?: a prospective randomized trial
    Johannes Cip
    Department of Orthopaedic Surgery, Academic Teaching Hospital, Medical University of Innsbruck, Carinagasse 47, A 6800, Feldkirch, Austria
    Clin Orthop Relat Res 471:1319-25. 2013
  10. ncbi request reprint Frameless stereotactic cannulation of the foramen ovale for ablative treatment of trigeminal neuralgia
    Reto J Bale
    Department of Radiology, Medical University Innsbruck, Innsbruck, Austria
    Neurosurgery 59:ONS394-401; discussion ONS402. 2006

Collaborators

Detail Information

Publications10

  1. ncbi request reprint [Relevance of wound drainage in total knee arthroplasty--a prospective comparative study]
    A Martin
    Lehrkrankenhaus der Universität Innsbruck, Landeskrankenhaus Feldkirch, Orthopädie und orthopädische Chirurgie, Feldkirch, Austria
    Z Orthop Ihre Grenzgeb 142:46-50. 2004
    ..The benefits of postoperative wound drainage in patients with total knee arthroplasty (TKA) with regards to mobilisation and wound healing were studied. We wanted to determine the efficacy of an autologous blood retransfusion system...
  2. ncbi request reprint [CT-based and CT-free navigation in total knee arthroplasty--a prospective comparative study with respects to clinical and radiological results]
    A Martin
    Lehrkrankenhaus der Universität Innsbruck, Landeskrankenhaus Feldkirch, Orthopädie und orthopädische Chirurgie, Feldkirch, Osterreich
    Z Orthop Ihre Grenzgeb 143:323-8. 2005
    ..With regard to clinical and radiological parameters, a comparative study between CT-based and CT-free navigation techniques was performed...
  3. ncbi request reprint Two-year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties
    Arno Martin
    Department of Orthopedic Surgery, Academic Teaching Hospital, Medical University of Innsbruck, Feldkirch, Austria
    Clin Orthop Relat Res 449:275-82. 2006
    ..Level of Evidence: Therapeutic Study, Level II. See the Guidelines for Authors for a complete description of levels of evidence...
  4. pmc Transfusion of autologous blood from reinfusion systems in total knee arthroplasty
    A Martin
    Academic Teaching Hospital, Department of Orthopedic Surgery, Medical University of Innsbruck, Feldkirch, Austria
    Int Orthop 30:541-4. 2006
    ..The blood loss in the group with a suction drainage system was significantly higher. Our experiences since May 2002 with one drain without suction in 787 consecutive TKAs confirm all findings of the current study...
  5. doi request reprint Accuracy of side-cutting implantation instruments for total knee arthroplasty
    Arno Martin
    Department of Orthopedic Surgery, University Teaching Hospital, Medical University of Innsbruck, Carinagasse 47, 6800 Feldkirch, Austria
    Knee Surg Sports Traumatol Arthrosc 17:374-81. 2009
    ..Clinical outcomes and knee scores were similar in both groups. The navigation technique could not compensate for shortcomings of the implantation instruments...
  6. doi request reprint [Post-traumatic osteoarthritis of the knee: special indication for navigated TKA]
    A Martin
    Academic Teaching Hospital, Department of Orthopedic Surgery, Medical University of Innsbruck, Carinagasse 47, A 6800 Feldkirch, Osterreich
    Unfallchirurg 111:754-8. 2008
    ..In case 1 the femoral nail did not have to be removed, thus decreasing surgery duration by 40-60 min.In both cases, the impossibility of using a femoral intramedullary alignment rod could be compensated for by the navigation system...
  7. doi request reprint Comparison of two minimally invasive implantation instrument-sets for total knee arthroplasty
    Arno Martin
    Department of Orthopedic Surgery, University Teaching Hospital, Medical University of Innsbruck, Carinagasse 47, 6800 Feldkirch, Austria
    Knee Surg Sports Traumatol Arthrosc 18:359-66. 2010
    ..The clinical relevance of this study is that the quadriceps sparing side-cutting instrumentation should not be used for TKA because of unacceptable reduced implantation accuracy...
  8. ncbi request reprint Imageless navigation for TKA increases implantation accuracy
    Arno Martin
    Department of Orthopedic Surgery, Academic Teaching Hospital, Medical University of Innsbruck, Feldkirch, Austria
    Clin Orthop Relat Res 460:178-84. 2007
    ..The navigation system increased implantation accuracy but did not prevent outliers and did not solve the problems associated with identifying and obtaining accurate component rotation...
  9. pmc Does single use of an autologous transfusion system in TKA reduce the need for allogenic blood?: a prospective randomized trial
    Johannes Cip
    Department of Orthopaedic Surgery, Academic Teaching Hospital, Medical University of Innsbruck, Carinagasse 47, A 6800, Feldkirch, Austria
    Clin Orthop Relat Res 471:1319-25. 2013
    ..Because of these contradictory findings it is still unclear whether autologous retransfusion systems for WSB can reduce transfusion requirements...
  10. ncbi request reprint Frameless stereotactic cannulation of the foramen ovale for ablative treatment of trigeminal neuralgia
    Reto J Bale
    Department of Radiology, Medical University Innsbruck, Innsbruck, Austria
    Neurosurgery 59:ONS394-401; discussion ONS402. 2006
    ..To maximize patient security and cannulation success, a frameless stereotactic system was evaluated in a phantom study, a cadaveric study, and a preliminary clinical trial...