G H White

Summary

Affiliation: University of Sydney
Country: Australia

Publications

  1. ncbi request reprint Type III and type IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair
    G H White
    Department of Vascular Surgery, Royal Prince Alfred Hospital, University of Sydney, NSW, Australia
    J Endovasc Surg 5:305-9. 1998
  2. ncbi request reprint Shortening of endografts during deployment in endovascular AAA repair
    G H White
    Department of Vascular Surgery, Royal Prince Alfred Hospital, University of Sydney, NSW, Australia
    J Endovasc Surg 6:4-10. 1999
  3. ncbi request reprint Endotension: an explanation for continued AAA growth after successful endoluminal repair
    G H White
    Department of Vascular Surgery, Royal Prince Alfred Hospital, University of Sydney, NSW, Australia
    J Endovasc Surg 6:308-15. 1999
  4. doi request reprint Improved outcomes with endovascular stent grafts for thoracic aorta transections
    I V Mohan
    Royal Prince Alfred Hospital, Missenden Road, Camperdown, Sydney, NSW, Australia
    Eur J Vasc Endovasc Surg 36:152-7. 2008
  5. ncbi request reprint Improved survival after endoluminal repair with second-generation prostheses compared with open repair in the treatment of abdominal aortic aneurysms: a 5-year concurrent comparison using life table method
    J May
    Department of Surgery, University of Sydney, New South Wales, Australia
    J Vasc Surg 33:S21-6. 2001
  6. ncbi request reprint Endovascular repair of abdominal aortic aneurysm in the multifocal atherosclerotic patient
    J May
    Department of Surgery, University of Sydney, NSW, Australia
    J Cardiovasc Surg (Torino) 44:341-7. 2003
  7. ncbi request reprint Endovascular popliteal aneurysm repair: are the results comparable to open surgery?
    I V Mohan
    Royal Prince Alfred Hospital, Missenden Road, Camperdown, Sydney, NSW, Australia
    Eur J Vasc Endovasc Surg 32:149-54. 2006
  8. ncbi request reprint Complications of aortic endografting
    J May
    Department of Surgery, University of Sydney, Sydney, Australia
    J Cardiovasc Surg (Torino) 46:359-69. 2005
  9. ncbi request reprint Diameter of large balloons used in endoluminal graft deployment varies with inflation pressure
    X Chaufour
    Department of Surgery, University of Sydney, Australia
    J Endovasc Surg 5:113-9. 1998
  10. ncbi request reprint Endotension. A review of current views on pathophysiology and treatment
    S R Dubenec
    Department of Vascular Surgery, Royal Prince Alfred Hospital, Sydney, Australia
    J Cardiovasc Surg (Torino) 44:553-7. 2003

Collaborators

Detail Information

Publications12

  1. ncbi request reprint Type III and type IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair
    G H White
    Department of Vascular Surgery, Royal Prince Alfred Hospital, University of Sydney, NSW, Australia
    J Endovasc Surg 5:305-9. 1998
    ....
  2. ncbi request reprint Shortening of endografts during deployment in endovascular AAA repair
    G H White
    Department of Vascular Surgery, Royal Prince Alfred Hospital, University of Sydney, NSW, Australia
    J Endovasc Surg 6:4-10. 1999
    ..To evaluate the incidence and extent of length changes during implantation of endovascular grafts in a prospective study of patients undergoing endovascular abdominal aortic aneurysm (AAA) repair...
  3. ncbi request reprint Endotension: an explanation for continued AAA growth after successful endoluminal repair
    G H White
    Department of Vascular Surgery, Royal Prince Alfred Hospital, University of Sydney, NSW, Australia
    J Endovasc Surg 6:308-15. 1999
    ..To present and analyze several cases that illustrate persistent sac pressurization following endovascular abdominal aortic aneurysm (AAA) repair...
  4. doi request reprint Improved outcomes with endovascular stent grafts for thoracic aorta transections
    I V Mohan
    Royal Prince Alfred Hospital, Missenden Road, Camperdown, Sydney, NSW, Australia
    Eur J Vasc Endovasc Surg 36:152-7. 2008
    ..To retrospectively assess the outcome of endovascular stent-graft implantation for thoracic aortic transections (ETAT)...
  5. ncbi request reprint Improved survival after endoluminal repair with second-generation prostheses compared with open repair in the treatment of abdominal aortic aneurysms: a 5-year concurrent comparison using life table method
    J May
    Department of Surgery, University of Sydney, New South Wales, Australia
    J Vasc Surg 33:S21-6. 2001
    ..The probability of survival with successful repair at 3 years was similar in both groups...
  6. ncbi request reprint Endovascular repair of abdominal aortic aneurysm in the multifocal atherosclerotic patient
    J May
    Department of Surgery, University of Sydney, NSW, Australia
    J Cardiovasc Surg (Torino) 44:341-7. 2003
    ..This view is based on the low perioperative mortality, superior survival compared with open repair and our experience of long-term stability in the proximal neck in the majority of patients...
  7. ncbi request reprint Endovascular popliteal aneurysm repair: are the results comparable to open surgery?
    I V Mohan
    Royal Prince Alfred Hospital, Missenden Road, Camperdown, Sydney, NSW, Australia
    Eur J Vasc Endovasc Surg 32:149-54. 2006
    ..The aim of this study was to review our experience of popliteal aneurysms using endovascular techniques...
  8. ncbi request reprint Complications of aortic endografting
    J May
    Department of Surgery, University of Sydney, Sydney, Australia
    J Cardiovasc Surg (Torino) 46:359-69. 2005
    ..This review discusses the local and vascular complications of endovascular repair of abdominal aortic aneurysm with an emphasis on newer aspects...
  9. ncbi request reprint Diameter of large balloons used in endoluminal graft deployment varies with inflation pressure
    X Chaufour
    Department of Surgery, University of Sydney, Australia
    J Endovasc Surg 5:113-9. 1998
    ..To evaluate the characteristics of large-diameter balloon catheters used during endoluminal repair of aortic aneurysms...
  10. ncbi request reprint Endotension. A review of current views on pathophysiology and treatment
    S R Dubenec
    Department of Vascular Surgery, Royal Prince Alfred Hospital, Sydney, Australia
    J Cardiovasc Surg (Torino) 44:553-7. 2003
    ..This paper reviews current theories and experimental evidence regarding the possible mechanisms of causation of endotension, and early experiences with treatment...
  11. ncbi request reprint Endoluminal repair of a complex tortuous descending thoracic aortic aneurysm
    R Huilgol
    Department of Vascular Surgery, Royal Prince Alfred Hospital and University of Sydney, Sydney, NSW, Australia
    Eur J Vasc Endovasc Surg 25:175-7. 2003
  12. ncbi request reprint Endoluminal repair of abdominal aortic aneurysms - state of the art
    J May
    Department of Surgery, University of Sydney DO6, NSW 2006, Sydney, Australia
    Eur J Radiol 39:16-21. 2001
    ..The small incidence of unpredictable rupture following endoluminal AAA repair is a timely reminder of the need for continued careful follow-up...