Stuart A Callary

Summary

Affiliation: South Australia
Country: Australia

Publications

  1. pmc Low wear of a second-generation highly crosslinked polyethylene liner: a 5-year radiostereometric analysis study
    Stuart A Callary
    Centre for Orthopaedic and Trauma Research, Level 4 Bice Building, University of Adelaide and Royal Adelaide Hospital, North Terrace, Adelaide, 5000, South Australia, Australia
    Clin Orthop Relat Res 471:3596-600. 2013
  2. pmc Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study
    Stuart A Callary
    Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, SA, Australia
    Clin Orthop Relat Res 471:2238-44. 2013
  3. doi request reprint The 6-year migration characteristics of a hydroxyapatite-coated femoral stem: a radiostereometric analysis study
    Stuart A Callary
    Discipline of Orthopaedics and Trauma, University of Adelaide and Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
    J Arthroplasty 27:1344-1348.e1. 2012
  4. pmc Second-generation highly cross-linked X3™ polyethylene wear: a preliminary radiostereometric analysis study
    David G Campbell
    Wakefield Orthopaedic Clinic, 270 Wakefield Street, Adelaide, SA, 5000, Australia
    Clin Orthop Relat Res 468:2704-9. 2010
  5. pmc Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study
    David Campbell
    Orthopaedic Unit, Repatriation General Hospital, Adelaide, South Australia, Australia
    Int Orthop 35:483-8. 2011
  6. doi request reprint Periprosthetic osteolysis after total hip replacement: molecular pathology and clinical management
    Donald W Howie
    Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
    Inflammopharmacology 21:389-96. 2013
  7. doi request reprint A preclinical study of stem subsidence and graft incorporation after femoral impaction grafting using porous hydroxyapatite as a bone graft extender
    Donald W Howie
    The Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
    J Arthroplasty 26:1050-6. 2011
  8. doi request reprint The effect of hip position on the length of trochanteric muscles: potential implications for early postoperative management of hip arthroplasty
    Yu C Lee
    Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
    J Arthroplasty 27:953-60.e1-2. 2012
  9. pmc The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures
    Lucian B Solomon
    Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, Australia
    Acta Orthop 81:487-94. 2010
  10. ncbi request reprint Impaction bone grafting of segmental bone defects in femoral non-unions
    Lucian B Solomon
    Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
    Acta Orthop Belg 79:64-70. 2013

Collaborators

Detail Information

Publications14

  1. pmc Low wear of a second-generation highly crosslinked polyethylene liner: a 5-year radiostereometric analysis study
    Stuart A Callary
    Centre for Orthopaedic and Trauma Research, Level 4 Bice Building, University of Adelaide and Royal Adelaide Hospital, North Terrace, Adelaide, 5000, South Australia, Australia
    Clin Orthop Relat Res 471:3596-600. 2013
    ..However, that study used measurements made from plain radiographs, which have limited sensitivity, particularly when monitoring very low amounts of wear...
  2. pmc Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study
    Stuart A Callary
    Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, SA, Australia
    Clin Orthop Relat Res 471:2238-44. 2013
    ..1 mm/year of wear, which is an historical threshold for osteolysis. Previous studies have measured wear on plain radiographs, an approach that has limited sensitivity...
  3. doi request reprint The 6-year migration characteristics of a hydroxyapatite-coated femoral stem: a radiostereometric analysis study
    Stuart A Callary
    Discipline of Orthopaedics and Trauma, University of Adelaide and Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
    J Arthroplasty 27:1344-1348.e1. 2012
    ..03 mm, which is below the limit measurable by radiostereometric analysis. The data demonstrate that subsidence of this cementless stem occurs within the first 6 months, after which there is persistent stabilization...
  4. pmc Second-generation highly cross-linked X3™ polyethylene wear: a preliminary radiostereometric analysis study
    David G Campbell
    Wakefield Orthopaedic Clinic, 270 Wakefield Street, Adelaide, SA, 5000, Australia
    Clin Orthop Relat Res 468:2704-9. 2010
    ..Owing to its recent introduction, there are no publications describing its clinical performance...
  5. pmc Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study
    David Campbell
    Orthopaedic Unit, Repatriation General Hospital, Adelaide, South Australia, Australia
    Int Orthop 35:483-8. 2011
    ..The results from this study can be compared with those from novel cementless stem designs to help predict the long-term outcome one may expect from new cementless stem designs...
  6. doi request reprint Periprosthetic osteolysis after total hip replacement: molecular pathology and clinical management
    Donald W Howie
    Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
    Inflammopharmacology 21:389-96. 2013
    ..Finally, there have been advances in the materials used for bearing surfaces to minimise wear, and we review the literature regarding the performance of these new materials to date. ..
  7. doi request reprint A preclinical study of stem subsidence and graft incorporation after femoral impaction grafting using porous hydroxyapatite as a bone graft extender
    Donald W Howie
    The Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
    J Arthroplasty 26:1050-6. 2011
    ..The comparable histologic results between groups and good stem fixation in this study support the conduct of a larger scale investigation of the use of porous HA in femoral impaction bone grafting at revision hip arthroplasty...
  8. doi request reprint The effect of hip position on the length of trochanteric muscles: potential implications for early postoperative management of hip arthroplasty
    Yu C Lee
    Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
    J Arthroplasty 27:953-60.e1-2. 2012
    ..This lengthening was prevented, and therefore, theoretically, the gluteus medius repair protected after a lateral approach, by neutral or internal femoral rotation...
  9. pmc The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures
    Lucian B Solomon
    Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, Australia
    Acta Orthop 81:487-94. 2010
    ..We therefore evaluated the accuracy and precision of RSA in a tibial plateau fracture model...
  10. ncbi request reprint Impaction bone grafting of segmental bone defects in femoral non-unions
    Lucian B Solomon
    Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
    Acta Orthop Belg 79:64-70. 2013
    ..All three patients were fully weight-bearing by three months postoperatively. At two years follow-up, plain radiographs demonstrated maintenance of reduction and healing in all three cases...
  11. doi request reprint Can tibial plateau fractures be reduced and stabilised through an angiosome-sparing antero-lateral approach?
    Lucian B Solomon
    Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, SA 5000, Australia Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA 5000, Australia Electronic address
    Injury 45:766-74. 2014
    ..The aim of this study was to develop an angiosome-sparing antero-lateral approach to allow reduction and fixation of lateral TPFs and to investigate its feasibility in a consecutive cohort...
  12. pmc Emerging ideas: soft tissue applications of radiostereometric analysis
    Lucian B Solomon
    Department of Orthopaedics and Trauma, University of Adelaide and Royal Adelaide Hospital, Level 4 Bice Building, RAH, North Terrace, Adelaide, SA 5000, Australia
    Clin Orthop Relat Res 469:1512-6. 2011
    ....
  13. pmc Differentially loaded radiostereometric analysis to monitor fracture stiffness: a feasibility study
    Mellick J Chehade
    Discipline of Orthopaedics and Trauma, The University of Adelaide, Adelaide, Australia
    Clin Orthop Relat Res 467:1839-47. 2009
    ..The method provides objective and quantifiable data for internally fixed fractures and may be used in clinical research as a tool to monitor the in vivo stiffness of healing femoral fractures managed with nonrigid internal fixation...
  14. ncbi request reprint The correlation of RANK, RANKL and TNFalpha expression with bone loss volume and polyethylene wear debris around hip implants
    Christopher A Holding
    Department of Pathology, The University of Adelaide, North Terrace, Adelaide, South Australia 5000, Australia
    Biomaterials 27:5212-9. 2006
    ..This suggests that the interaction of TNFalpha and RANKL promotes osteoclast activity associated with polyethylene wear and therapies targeting TNF activity may be useful to treat peri-implant osteolysis...