Ganesh Adluru

Summary

Publications

  1. doi request reprint Reconstruction of 3D dynamic contrast-enhanced magnetic resonance imaging using nonlocal means
    Ganesh Adluru
    UCAIR, Department of Radiology, University of Utah, Salt Lake City, Utah 84108, USA
    J Magn Reson Imaging 32:1217-27. 2010
  2. pmc Three-dimensional late gadolinium enhancement imaging of the left atrium with a hybrid radial acquisition and compressed sensing
    Ganesh Adluru
    UCAIR, Department of Radiology, University of Utah, Salt Lake City, Utah, USA CARMA, Department of Internal Medicine, University of Utah, Salt Lake City, Utah, USA
    J Magn Reson Imaging 34:1465-71. 2011
  3. pmc Myocardial perfusion MRI with an undersampled 3D stack-of-stars sequence
    Liyong Chen
    Department of Bioengineering, University of Utah, Salt Lake City, Utah 84108, USA
    Med Phys 39:5204-11. 2012
  4. pmc Acquisition and reconstruction of undersampled radial data for myocardial perfusion magnetic resonance imaging
    Ganesh Adluru
    Electrical and Computer Engineering Department, University of Utah, Salt Lake City, Utah, USA
    J Magn Reson Imaging 29:466-73. 2009
  5. pmc The effect of obesity on regadenoson-induced myocardial hyperemia: a quantitative magnetic resonance imaging study
    Edward V R DiBella
    UCAIR, Department of Radiology, University of Utah, Salt Lake City, UT, USA
    Int J Cardiovasc Imaging 28:1435-44. 2012
  6. doi request reprint Myocardial perfusion acquisition without magnetization preparation or gating
    Edward V R DiBella
    Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, Utah, USA
    Magn Reson Med 67:609-13. 2012
  7. ncbi request reprint Model-based registration for dynamic cardiac perfusion MRI
    Ganesh Adluru
    Electrical and Computer Engineering Department, University of Utah, Salt Lake City, Utah 84108, USA
    J Magn Reson Imaging 24:1062-70. 2006
  8. pmc Temporally constrained reconstruction applied to MRI temperature data
    Nick Todd
    Department of Physics, University of Utah, Salt Lake City, Utah 84108, USA
    Magn Reson Med 62:406-19. 2009
  9. ncbi request reprint Temporally constrained reconstruction of dynamic cardiac perfusion MRI
    Ganesh Adluru
    Electrical and Computer Engineering Department, University of Utah, Salt Lake City, UT, USA
    Magn Reson Med 57:1027-36. 2007
  10. doi request reprint Model-based reconstruction of undersampled diffusion tensor k-space data
    Christopher L Welsh
    Department of Bioengineering, University of Utah, Salt Lake City, Utah, USA UCAIR, Department of Radiology, University of Utah, Salt Lake City, Utah, USA
    Magn Reson Med 70:429-40. 2013

Detail Information

Publications11

  1. doi request reprint Reconstruction of 3D dynamic contrast-enhanced magnetic resonance imaging using nonlocal means
    Ganesh Adluru
    UCAIR, Department of Radiology, University of Utah, Salt Lake City, Utah 84108, USA
    J Magn Reson Imaging 32:1217-27. 2010
    ..To develop and test a nonlocal means-based reconstruction algorithm for undersampled 3D dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of tumors...
  2. pmc Three-dimensional late gadolinium enhancement imaging of the left atrium with a hybrid radial acquisition and compressed sensing
    Ganesh Adluru
    UCAIR, Department of Radiology, University of Utah, Salt Lake City, Utah, USA CARMA, Department of Internal Medicine, University of Utah, Salt Lake City, Utah, USA
    J Magn Reson Imaging 34:1465-71. 2011
    ..To develop and test a hybrid radial (stack of stars) acquisition and compressed sensing reconstruction for efficient late gadolinium enhancement (LGE) imaging of the left atrium...
  3. pmc Myocardial perfusion MRI with an undersampled 3D stack-of-stars sequence
    Liyong Chen
    Department of Bioengineering, University of Utah, Salt Lake City, Utah 84108, USA
    Med Phys 39:5204-11. 2012
    ..To determine the feasibility of three-dimensional (3D) hybrid radial (stack-of-stars) MRI with spatiotemporal total variation (TV) constrained reconstruction for dynamic contrast enhanced myocardial perfusion imaging...
  4. pmc Acquisition and reconstruction of undersampled radial data for myocardial perfusion magnetic resonance imaging
    Ganesh Adluru
    Electrical and Computer Engineering Department, University of Utah, Salt Lake City, Utah, USA
    J Magn Reson Imaging 29:466-73. 2009
    ..To improve myocardial perfusion magnetic resonance imaging (MRI) by reconstructing undersampled radial data with a spatiotemporal constrained reconstruction method (STCR)...
  5. pmc The effect of obesity on regadenoson-induced myocardial hyperemia: a quantitative magnetic resonance imaging study
    Edward V R DiBella
    UCAIR, Department of Radiology, University of Utah, Salt Lake City, UT, USA
    Int J Cardiovasc Imaging 28:1435-44. 2012
    ..Fixed dose regadenoson and weight adjusted adenosine produce similar measures of MPR in patients with a wide range of body sizes. Regadenoson is a potentially useful vasodilator for stress MRI studies...
  6. doi request reprint Myocardial perfusion acquisition without magnetization preparation or gating
    Edward V R DiBella
    Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, Utah, USA
    Magn Reson Med 67:609-13. 2012
    ..Preliminary results in one subject are presented to show the potential of this new approach. The method may allow for cine cardiac perfusion and more signal-to-noise ratio-efficient acquisitions...
  7. ncbi request reprint Model-based registration for dynamic cardiac perfusion MRI
    Ganesh Adluru
    Electrical and Computer Engineering Department, University of Utah, Salt Lake City, Utah 84108, USA
    J Magn Reson Imaging 24:1062-70. 2006
    ..To assess the accuracy of a model-based approach for registration of myocardial dynamic contrast-enhanced (DCE)-MRI corrupted by respiratory motion...
  8. pmc Temporally constrained reconstruction applied to MRI temperature data
    Nick Todd
    Department of Physics, University of Utah, Salt Lake City, Utah 84108, USA
    Magn Reson Med 62:406-19. 2009
    ..Compared with sliding window and low resolution reconstructions, the RMSE of the TCR algorithm was significantly lower (P < 0.05 in all cases)...
  9. ncbi request reprint Temporally constrained reconstruction of dynamic cardiac perfusion MRI
    Ganesh Adluru
    Electrical and Computer Engineering Department, University of Utah, Salt Lake City, UT, USA
    Magn Reson Med 57:1027-36. 2007
    ..The method has the potential to improve dynamic myocardial perfusion imaging and also to reconstruct other sparse dynamic MR acquisitions...
  10. doi request reprint Model-based reconstruction of undersampled diffusion tensor k-space data
    Christopher L Welsh
    Department of Bioengineering, University of Utah, Salt Lake City, Utah, USA UCAIR, Department of Radiology, University of Utah, Salt Lake City, Utah, USA
    Magn Reson Med 70:429-40. 2013
    ..The findings show model-based compressed sensing to be promising for improving the resolution, accuracy, or scan time of diffusion tensor imaging. Magn Reson Med 70:429-440, 2013. © 2012 Wiley Periodicals, Inc. ..
  11. pmc Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE
    Li Feng
    Department of Radiology, The Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, New York, USA Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
    Magn Reson Med 70:64-74. 2013
    ..Our proposed eightfold accelerated real-time cine MRI with k-t SPARSE-SENSE is a promising modality for rapid imaging of myocardial function. J. Magn. Reson. Imaging 2013. © 2012 Wiley Periodicals, Inc. ..