Research Topics
| Timothy M BatemanSummaryAffiliation: Mid America Heart Institute Country: USA Publications
| Collaborators
|
Detail Information
Publications
Initial clinical experience with regadenoson, a novel selective A2A agonist for pharmacologic stress single-photon emission computed tomography myocardial perfusion imagingRobert C Hendel
Rush University Medical Center, Chicago, Illinois, USA
J Am Coll Cardiol 46:2069-75. 2005....
Symptom-limited exercise during vasodilator stress: best of both worlds?Kevin A Bybee
J Nucl Cardiol 15:3-6. 2008
Multicenter investigation comparing a highly efficient half-time stress-only attenuation correction approach against standard rest-stress Tc-99m SPECT imagingTimothy M Bateman
Mid America Heart Institute, University of Missouri Kansas City, Kansas City, MO, USA
J Nucl Cardiol 16:726-35. 2009..We investigated the potential for half-time stress-only LSAC-SPECT by comparing this to conventional rest/stress SPECT in patients imaged for suspected CAD at three different centers...
Business aspects of cardiovascular computed tomography: tackling the challengesTimothy M Bateman
Cardiovascular Consultants, PA, 4320 Wornall Road, Suite 20000, Kansas City, Missouri 64111, USA
JACC Cardiovasc Imaging 1:111-8. 2008..With careful consideration of the business aspects, moderate-to-large size cardiology programs should be able to implement an economically viable cardiovascular computed tomographic service...
Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECTTimothy M Bateman
Cardiovascular Consultants, PC, Kansas City, MO 64111, USA
J Nucl Cardiol 13:24-33. 2006..This study was designed to assess relative image quality, interpretive confidence, and diagnostic accuracy by use of contemporary technology and protocols...
Cardiac positron emission tomography and the role of adenosine pharmacologic stressTimothy M Bateman
Mid America Heart Institute, Kansas City, Missouri 64111, USA
Am J Cardiol 94:19D-24D; discussion 24D-25D. 2004..With the resolution of technical issues, cardiac PET has an opportunity to become the standard for evaluation of myocardial perfusion in the coming years...
Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass indexRandall C Thompson
Mid America Heart Institute and Cardiovascular Consultants, 4330 Wornall Street, Kansas City, MO 64111, USA
J Nucl Cardiol 12:195-202. 2005..Obesity is a growing problem in the United States, and attenuation artifacts are more prevalent in this patient group. This study evaluated the impact of attenuation correction in patients with a high body mass index (BMI)...
Clinical utility of coronary calcium scoring after nonischemic myocardial perfusion imagingRandall C Thompson
Cardiovascular Consultants PC, 4330 Wornall Road, Suite 2000, Kansas City, MO 64111, USA
J Nucl Cardiol 12:392-400. 2005..Coronary artery calcium (CAC) scoring is increasingly being used after myocardial perfusion imaging (MPI) to detect preclinical coronary artery disease (CAD). However, there are few data to support this approach...
Reconstruction of rapidly acquired Germanium-68 transmission scans for cardiac PET attenuation correctionBai Ling Hsu
Cardiovascular Imaging Technologies, LLC, Kansas City, MO 64111, USA
J Nucl Cardiol 14:706-14. 2007..A reconstruction algorithm combining ordered-subsets expectation maximization with a Bayesian prior was developed and applied to rapid Germanium-68 (Ge-68) TX scans...
A Bayesian iterative transmission gradient reconstruction algorithm for cardiac SPECT attenuation correctionJames A Case
Cardiovascular Imaging Technologies, LLC, Kansas City, MO 64111, USA
J Nucl Cardiol 14:324-33. 2007..The filtered backprojection (FBP) approach can introduce errors, especially with low-count transmission data. We present a new method for attenuation map reconstruction and examine its performance in phantom and patient data...
Diagnostic and clinical benefit of combined coronary calcium and perfusion assessment in patients undergoing PET/CT myocardial perfusion stress imagingKevin A Bybee
University of Missouri Kansas City School of Medicine, Kansas City, MO, USA
J Nucl Cardiol 17:188-96. 2010..One advantage of MPI with a hybrid CT device is the ability to obtain same-setting measurement of the coronary artery calcium score (CACS)...
Interscan variability of coronary artery calcium quantification using an electrocardiographically pulsed spiral computed tomographic protocolKevin W Moser
Cardiovascular Imaging Technologies, L L C, Kansas City, Missouri, USA
Am J Cardiol 93:1153-5. 2004..For Agatston scores <10, the interscan variability of such a protocol was significantly lower than that for a sequential acquisition protocol. At higher Agatston scores, the 2 protocols had similar variability characteristics...
Effect of chronic right ventricular apical pacing on left ventricular functionJames H O'Keefe
Mid America Heart Institute, Kansas City, Missouri 64111, USA
Am J Cardiol 95:771-3. 2005....
Attenuation correction single-photon emission computed tomography myocardial perfusion imagingTimothy M Bateman
Mid America Heart Institute, Kansas City, MO, USA
Semin Nucl Med 35:37-51. 2005....
Coronary calcium screening in asymptomatic patients as a guide to risk factor modification and stress myocardial perfusion imagingKevin W Moser
Cardiovascular Consultants, Mid America Heart Institute, Saint Luke's Hospital, Kansas City, MO 64111, USA
J Nucl Cardiol 10:590-8. 2003..Finally, this study demonstrated that an Agatston score of 400 is a logical threshold to initiate follow-up myocardial perfusion SPECT testing...
Best patient preparation before and during radionuclide myocardial perfusion imaging studiesLisa A Boger
Cardiovascular Consultants, PC, Kansas City, MO 64111, USA
J Nucl Cardiol 13:98-110. 2006
Quantitative Tc-99m sestamibi attenuation-corrected SPECT: development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese populationGabriel B Grossman
Emory University, Atlanta, GA, USA
J Nucl Cardiol 11:263-72. 2004..CONCLUSION: Attenuation-corrected studies can be quantified with a single gender-independent normal database and a single criterion for abnormality without loss of sensitivity and with significantly better specificity and normalcy rate...
ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 GuideliFrancis J Klocke
Circulation 108:1404-18. 2003
Attenuation artifact, attenuation correction, and the future of myocardial perfusion SPECTBhupinder Singh
J Nucl Cardiol 14:153-64. 2007
Attenuation correction reveals gender-related differences in the normal values of transient ischemic dilation index in rest-exercise stress sestamibi myocardial perfusion imagingAbel Rivero
Emory University School of Medicine, Atlanta, GA 30322, USA
J Nucl Cardiol 13:338-44. 2006....
Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imagingGary V Heller
Nuclear Cardiology Laboratory, Hartford Hospital, CT 06102 5037, USA
J Nucl Cardiol 11:273-81. 2004..Attenuation-corrected stress-only imaging has the potential to ameliorate these limitations...
Adenosine versus regadenoson comparative evaluation in myocardial perfusion imaging: results of the ADVANCE phase 3 multicenter international trialAmi E Iskandrian
University of Alabama at Birmingham, Birmingham, AL 35294 0006, USA
J Nucl Cardiol 14:645-58. 2007..Earlier phase 1 and 2 studies have shown that regadenoson has desirable features as a stress agent for myocardial perfusion imaging...
Positron emission tomography myocardial perfusion and glucose metabolism imagingJosef Machac
J Nucl Cardiol 13:e121-51. 2006
Metabolic imaging with beta-methyl-p-[(123)I]-iodophenyl-pentadecanoic acid identifies ischemic memory after demand ischemiaVasken Dilsizian
Division of Nuclear Medicine, University of Maryland Hospital and School of Medicine, Baltimore, MD 21201 1595, USA
Circulation 112:2169-74. 2005..We hypothesized that a branched-chain fatty acid, beta-methyl-p-[(123)I]-iodophenyl-pentadecanoic acid (BMIPP), might identify the presence of myocardial ischemia late after demand ischemia at rest up to 30 hours later...
American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: attenuation correction of myocardial perfusion SPECT scintigraphyGary V Heller
J Nucl Cardiol 11:229-30. 2004
Use of phantom studies to compare the performance of 8 different attenuation correction devicesErnest V Garcia
J Nucl Cardiol 10:107-8; author reply 108-9. 2003
The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear MedicineRobert C Hendel
J Nucl Cardiol 9:135-43. 2002
