Research Topics
| Jurgen J FuttererSummaryAffiliation: Radboud University Nijmegen Medical Centre Country: The Netherlands Publications
| Collaborators
|
Detail Information
Publications
Protocol for translabial 3D-ultrasonography for diagnosing levator defects (TRUDIL): a multicentre cohort study for estimating the diagnostic accuracy of translabial 3D-ultrasonography of the pelvic floor as compared to MR imagingKim J B Notten
Department of Obstetrics and Gynecology, Maastricht University Medical Centre, The Netherlands
BMC Womens Health 11:23. 2011..Anticipating 3% unclassifiable diagnostic images because of technical reasons, and a further safety margin of 10% we plan to recruit 140 patients. TRIAL REGISTRATION: Nederlands trial register NTR2220...
Prostate cancer: comparison of local staging accuracy of pelvic phased-array coil alone versus integrated endorectal-pelvic phased-array coils. Local staging accuracy of prostate cancer using endorectal coil MR imagingJurgen J Futterer
Department of Radiology, University Medical Center Nijmegen, Nijmegen, The Netherlands
Eur Radiol 17:1055-65. 2007..Overstaging is reduced significantly with equal sensitivity when an endorectal-pelvic phased-array coil is used...
Imaging the male reproductive tract: current trends and future directionsJurgen J Futterer
Department of Radiology, University Medical Centre Nijmegen, Nijmegen, The Netherlands
Radiol Clin North Am 46:133-47, vii. 2008..This review focuses on the prostate and scrotum...
Preoperative 3T MR imaging of rectal cancer: local staging accuracy using a two-dimensional and three-dimensional T2-weighted turbo spin echo sequenceJurgen J Futterer
Department of Radiology, Radboud University Nijmegen Medical Center, The Netherlands
Eur J Radiol 65:66-71. 2008..The purpose of our study was to evaluate the image quality and diagnostic performance of two-dimensional (D) turbo spin echo (TSE) and 3D T2-weighted TSE MR imaging in local staging of rectal cancer at 3T...
MR imaging in local staging of prostate cancerJurgen J Futterer
Department of Radiology, Radboud University Nijmegen Medical Centre, Geert Grooteplein zuid 10, NL 6500 HB Nijmegen, The Netherlands
Eur J Radiol 63:328-34. 2007..The diagnostic capability of MR imaging in preoperative staging of prostate cancer is currently being established. In this review the role of MR imaging in staging prostate cancer is discussed...
Standardized threshold approach using three-dimensional proton magnetic resonance spectroscopic imaging in prostate cancer localization of the entire prostateJurgen J Futterer
Department of Radiology, Radboud University Nijmegen Medical Center, The Netherlands
Invest Radiol 42:116-22. 2007..We sought to determine the localization accuracy using 3-dimensional (3D) proton magnetic resonance spectroscopic imaging (MRSI) of the entire prostate with a standardized thresholds approach in prostate cancer patients...
Value of 3-T magnetic resonance imaging in local staging of prostate cancerJurgen J Futterer
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
Top Magn Reson Imaging 19:285-9. 2008..Furthermore, the current diagnostic performance of prostate MR imaging in staging prostate cancer at high field strength is discussed...
Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imagingJurgen J Futterer
Department of Radiology, Radboud University Nijmegen Medical Center, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, The Netherlands
Radiology 241:449-58. 2006....
Imaging modalities for prostate cancerJurgen J Futterer
Department of Radiology 667, Radboud University Nijmegen Medical Centre, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, The Netherlands
Expert Rev Anticancer Ther 9:923-37. 2009..The clinical value of these techniques in prostate cancer detection, localization, characterization, staging and active surveillance are discussed...
Prostate cancer: local staging at 3-T endorectal MR imaging--early experienceJurgen J Futterer
Department of Radiology, University Medical Center Nijmegen, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, The Netherlands
Radiology 238:184-91. 2006..To prospectively investigate the local staging accuracy of 3-T endorectal magnetic resonance (MR) imaging for prostate cancer by using whole-mount-section histopathologic analysis as the standard of reference...
Staging prostate cancer with dynamic contrast-enhanced endorectal MR imaging prior to radical prostatectomy: experienced versus less experienced readersJurgen J Futterer
Department of Radiology, University Medical Center Nijmegen, The Netherlands
Radiology 237:541-9. 2005....
Initial experience of 3 tesla endorectal coil magnetic resonance imaging and 1H-spectroscopic imaging of the prostateJurgen J Futterer
Department of Radiology, University Medical Center Nijmegen, Nijmegen The Netherlands
Invest Radiol 39:671-80. 2004..We sought to explore the feasibility of magnetic resonance imaging (MRI) of the prostate at 3T, with the knowledge of potential drawbacks of MRI at high field strengths...
MRI with a lymph-node-specific contrast agent as an alternative to CT scan and lymph-node dissection in patients with prostate cancer: a prospective multicohort studyRoel A M Heesakkers
Department of Radiology, Radboud University Medical Centre, Nijmegen, Netherlands
Lancet Oncol 9:850-6. 2008..In this prospective, multicentre cohort study, we aimed to compare the diagnostic accuracy of MRL with up-to-date multidetector CT (MDCT), and test the hypothesis that a negative MRL finding obviates the need for a PLND...
IMRT boost dose planning on dominant intraprostatic lesions: gold marker-based three-dimensional fusion of CT with dynamic contrast-enhanced and 1H-spectroscopic MRIEmile N J T van Lin
Department of Radiation Oncology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
Int J Radiat Oncol Biol Phys 65:291-303. 2006....
Prostate cancer: multiparametric MR imaging for detection, localization, and stagingCaroline M A Hoeks
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
Radiology 261:46-66. 2011..Supportive techniques, such as computer-aided diagnosis are needed to obtain a fast, cost-effective, easy, and more reproducible prostate cancer diagnosis out of more and more complex multiparametric MR imaging data...
Prostate cancer: body-array versus endorectal coil MR imaging at 3 T--comparison of image quality, localization, and staging performanceStijn W T P J Heijmink
Department of Radiology, Radboud University Nijmegen Medical Centre, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, The Netherlands
Radiology 244:184-95. 2007....
Initial results of 3-dimensional 1H-magnetic resonance spectroscopic imaging in the localization of prostate cancer at 3 Tesla: should we use an endorectal coil?Derya Yakar
Departments of Radiology, Radboud University Nijmegen Medical Centre, The Netherlands
Invest Radiol 46:301-6. 2011....
Magnetic resonance imaging guided prostate biopsy in men with repeat negative biopsies and increased prostate specific antigenThomas Hambrock
University Medical Centre St Radboud, Nijmegen, The Netherlands
J Urol 183:520-7. 2010..We compared results to those in a matched transrectal ultrasound guided prostate biopsy population. Also, we determined the clinical significance of detected tumors...
Prostate and lymph node proton magnetic resonance (MR) spectroscopic imaging with external array coils at 3 T to detect recurrent prostate cancer after radiation therapyStijn W T P J Heijmink
Department of Radiology, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands
Invest Radiol 42:420-7. 2007..1 mmol/kg water. Subsequent histopathological analysis of systematic transrectal ultrasound-guided prostate biopsy and computed tomography-guided biopsy of the lymph node confirmed the presence of prostate cancer in both...
Predictive value of MRI in the localization, staging, volume estimation, assessment of aggressiveness, and guidance of radiotherapy and biopsies in prostate cancerDerya Yakar
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
J Magn Reson Imaging 35:20-31. 2012..However, larger study populations in multicenter settings have to confirm these promising results. However, before such studies can be performed more research is needed in order to achieve standardized imaging protocols...
Feasibility of 3T dynamic contrast-enhanced magnetic resonance-guided biopsy in localizing local recurrence of prostate cancer after external beam radiation therapyDerya Yakar
Department of Radiology, Nijmegen Medical Centre, Radboud University, Nijmegen, The Netherlands
Invest Radiol 45:121-5. 2010....
[Multiparametric MRI for prostate cancer screening]Caroline M A Hoeks
Universitair Medisch Centrum St Radboud, Afd Radiologie, Nijmegen, The Netherlands
Ned Tijdschr Geneeskd 153:B487. 2009..Using multiparametric MRI as a follow-up test during screening would provide more accurate biopsies, prevent unnecessary prostate biopsies and improve the characterization of prostate cancer...
Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibilityThomas Hambrock
Department of Radiology, University Medical Centre Nijmegen, Nijmegen, Netherlands
Invest Radiol 43:686-94. 2008..Furthermore, to evaluate the practicability of MR-guided biopsy on a 3T MR scanner using a 32-channel coil and a MR-compatible biopsy device...
Use of ultrasmall superparamagnetic iron oxide in lymph node MR imaging in prostate cancer patientsJelle O Barentsz
Department of Radiology, Radboud University Nijmegen Medical Center, The Netherlands
Eur J Radiol 63:369-72. 2007..However, thorough knowledge of sequence parameters and planes, lymph node anatomy, appearance of normal and abnormal nodes, is essential when using this technique. This will be elaborated in this review...
Magnetic resonance-guided biopsy of the prostate: feasibility, technique, and clinical applicationsDerya Yakar
Department of Radiology, Radboud University, Nijmegen Medical Centre, Geert Grooteplein Zuid, Nijmegen, The Netherlands
Top Magn Reson Imaging 19:291-5. 2008..To describe the technique of magnetic resonance (MR)-guided biopsy as performed in our institution and highlight trends from current literature...
Feasibility of a pneumatically actuated MR-compatible robot for transrectal prostate biopsy guidanceDerya Yakar
Department of Radiology, Radboud University Nijmegen Medical Centre, Geert Grooteplein 10, 6500 HB Nijmegen, The Netherlands
Radiology 260:241-7. 2011..To assess the feasibility of using a remote-controlled, pneumatically actuated magnetic resonance (MR)-compatible robotic device to aid transrectal biopsy of the prostate performed with real-time 3-T MR imaging guidance...
Initial experience with identifying high-grade prostate cancer using diffusion-weighted MR imaging (DWI) in patients with a Gleason score ? 3 + 3 = 6 upon schematic TRUS-guided biopsy: a radical prostatectomy correlated seriesDiederik M Somford
Department of Urology, Canisius Wilhelmina Hospital Nijmegen CWZ, Nijmegen, The Netherlands
Invest Radiol 47:153-8. 2012..We aimed to determine whether DWI is able to correctly identify those patients with a biopsy Gleason score of ? 3 + 3 = 6, but harboring Gleason 4 and/or 5 components in their radical prostatectomy (RP) specimen...
Optimal timing for in vivo 1H-MR spectroscopic imaging of the human prostate at 3TTom W J Scheenen
Department of Radiology, University Medical Center Nijmegen, 6525 GA Nijmegen, The Netherlands
Magn Reson Med 53:1268-74. 2005..This is illustrated by means of a 3D spectroscopic imaging experiment in a complete prostate in vivo...
Computerized analysis of prostate lesions in the peripheral zone using dynamic contrast enhanced MRIPieter C Vos
Department of Radiology, Radboud University Nijmegen Medical Centre, Geert Grooteplein 18, 6525 GA Nijmegen, The Netherlands
Med Phys 35:888-99. 2008..83 (0.75-0.92). This suggests that it is feasible to develop a computer aided diagnosis system capable of characterizing prostate cancer in the peripheral zone based on DCE-MRI...
Dynamic magnetic resonance imaging: reliability of anatomical landmarks and reference lines used to assess pelvic organ prolapseSuzan R Broekhuis
Department of Obstetrics and Gynecology, Radboud University Nijmegen Medical Centre, P O Box 9101, 6500 HB, Nijmegen, The Netherlands
Int Urogynecol J Pelvic Floor Dysfunct 20:141-8. 2009..20-0.96). The intra- and interobserver reliability of quantitative prolapse staging on dynamic MR imaging were good to excellent. The pubococcygeal line appears the most reliable to use...
Prostate cancer: precision of integrating functional MR imaging with radiation therapy treatment by using fiducial gold markersHenkjan J Huisman
Department of Radiology, Radboud University Nijmegen Medical Center, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, Netherlands
Radiology 236:311-7. 2005..01) than that of the landmark method (2.0 mm). Furthermore, a method is described by which multimodal MR imaging data are reduced into a single interpreted volume that, after registration, can be incorporated into treatment planning...
Fast acquisition-weighted three-dimensional proton MR spectroscopic imaging of the human prostateTom W J Scheenen
Department of Radiology, University Medical Center Nijmegen, Nijmegen, The Netherlands
Magn Reson Med 52:80-8. 2004..At 1.5 T, the MR-visible prostate metabolites citrate, creatine, and choline can now be mapped over the entire human prostate with uncontaminated spherical voxels, with a volume down to 0.37 cm3, in measurement times of 7-15 min...
Reproducibility of 3D 1H MR spectroscopic imaging of the prostate at 1.5TMiriam W Lagemaat
Department of Radiology 767, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
J Magn Reson Imaging 35:166-73. 2012..To determine the reproducibility of 3D proton magnetic resonance spectroscopic imaging ((1)H-MRSI) of the human prostate in a multicenter setting at 1.5T...
Evaluation of a robotic technique for transrectal MRI-guided prostate biopsiesMartijn G Schouten
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, Netherlands
Eur Radiol 22:476-83. 2012..To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions...
Prostate cancer evaluated with ferumoxtran-10-enhanced T2*-weighted MR Imaging at 1.5 and 3.0 T: early experienceRoel A M Heesakkers
Department of Radiology and Medical Technology Assessment, University Medical Center Nijmegen, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, The Netherlands
Radiology 239:481-7. 2006..0 T) and to compare image quality between 1.5- and 3.0-T MR imaging in terms of lymph node detection in patients with prostate cancer...
The accuracy and safety aspects of a novel robotic needle guide manipulator to perform transrectal prostate biopsiesMartijn G Schouten
Department of Radiology, Nijmegen Medical Centre, Radboud University, Nijmegen, Gelderland 6500 HB, Netherlands
Med Phys 37:4744-50. 2010..To introduce a new in-house developed pneumatically controlled magnetic field compatible manipulator as an aid to perform magnetic resonance (MR)-guided biopsies of the prostate...
Perineal descent and patients' symptoms of anorectal dysfunction, pelvic organ prolapse, and urinary incontinenceSuzan R Broekhuis
791 Department of Obstetrics and Gynecology, Radboud University Nijmegen Medical Centre, PO Box 9101, 6500 HB Nijmegen, The Netherlands
Int Urogynecol J 21:721-9. 2010..The aim of this dynamic magnetic resonance (MR) imaging study was to assess the relation between the position and mobility of the perineum and patients' symptoms of pelvic floor dysfunction...
A systematic review of clinical studies on dynamic magnetic resonance imaging of pelvic organ prolapse: the use of reference lines and anatomical landmarksSuzan R Broekhuis
Department of Obstetrics and Gynecology 791, Radboud University Nijmegen Medical Centre, Geert Grooteplein zuid 10, 6500 HB, Nijmegen, The Netherlands
Int Urogynecol J Pelvic Floor Dysfunct 20:721-9. 2009..The aim of our study was to provide a systematic literature review of clinical studies on pelvic organ prolapse staging with use of dynamic magnetic resonance (MR) imaging...
Diffusion and perfusion MR imaging of the prostateDiederik M Somford
Department of Urology, Radboud University, Nijmegan Medical Centre, Nijmegen, The Netherlands
Magn Reson Imaging Clin N Am 16:685-95, ix. 2008....
State-of-the-art uroradiologic imaging in the diagnosis of prostate cancerStijn W T P J Heijmink
Department of Radiology, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands
Acta Oncol 50:25-38. 2011..Subsequently, a proposal for optimal use of radiologic imaging is presented and compared with the European and American urological guidelines on prostate cancer...
In vivo imaging of the aneurysm wall with MRI and a macrophage-specific contrast agentMaarten Truijers
Department of Surgery and Vascular Surgery, Radboud University, Nijmegen Medical Center, Gelderland, 6500HB Nijmegen, The Netherlands
AJR Am J Roentgenol 193:W437-41. 2009..We studied uptake of the macrophage-specific contrast agent ultrasmall paramagnetic iron oxide (USPIO) in the walls of aneurysms and normal-sized aortas...
Variability in the description of morphologic and contrast enhancement characteristics of breast lesions on magnetic resonance imagingMark J Stoutjesdijk
Radboud University Nijmegen Medical Centre, Department of Radiology, The Netherlands
Invest Radiol 40:355-62. 2005..The objective of this study was to evaluate the interobserver variability in reporting descriptive kinetic and morphologic enhancement features at breast magnetic resonance imaging...
Rectal obstruction after a vaginal posterior compartment polypropylene mesh fixed to the sacrospinous ligamentsMark E Vierhout
Department of Obstetrics and Gynaecology, Radboud University Nijmegen Medical Centre, PO Box 9101, 6500 HB Nijmegen, The Netherlands
Int Urogynecol J 22:1035-7. 2011..It is hypothesised that the obstruction was due to the fixation of the mesh with irresolvable suture material to the sacrospinous ligaments acting as a hinge on which the bowel folded...
ESUR prostate MR guidelines 2012Jelle O Barentsz
Department of Radiology, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands
Eur Radiol 22:746-57. 2012..Clinical indications, and minimal and optimal imaging acquisition protocols are provided. A structured reporting system (PI-RADS) is described...
Symptoms of pelvic floor dysfunction are poorly correlated with findings on clinical examination and dynamic MR imaging of the pelvic floorSuzan R Broekhuis
791 Department of Obstetrics and Gynecology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
Int Urogynecol J Pelvic Floor Dysfunct 20:1169-74. 2009..The aim of the study was to determine whether patients' symptoms agree with findings on clinical examination and dynamic MR imaging of the pelvic floor...
