Research Topics
| Piergiorgio TozziSummaryAffiliation: Centre Hospitalier Universitaire Vaudois Country: Switzerland Publications
| Collaborators
|
Detail Information
Publications
Endoscopic access closure for direct implantation of valved stentsPiergiorgio Tozzi
Department of Cardiovascular Surgery, University of Lausanne CHUV, Lausanne, Switzerland
Swiss Med Wkly 137:182-4. 2007..One of the key steps in this procedure is the repair of the ventricle after catheter withdrawal. This study evaluates the reliability of a new device for sutureless and quick repair of the left ventricle access...
Endoscopic off-pump aortic valve replacement: does the pericardial cuff improve the sutureless closure of left ventricular access?Piergiorgio Tozzi
Cardiovascular Surgery Department, University of Lausanne CHUV, Rue du Bugnon 46, 1011 Lausanne, Switzerland
Eur J Cardiothorac Surg 31:22-5. 2007..We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side...
Progress in cardiovascular anastomoses: will the vascular join replace Carrel's technique?Piergiorgio Tozzi
Cardiovascular Surgery Department, University of Lausanne, CHUV, Lausanne, Switzerland
Eur J Cardiothorac Surg 30:425-30. 2006..Many sutureless anastomosis devices have been designed to facilitate the cardiovascular surgeon's work and the vascular join (VJ) is one of these. We designed an animal study to assess its reliability and long-term efficacy...
Temporary caval stenting improves venous drainage during cardiopulmonary bypassLudwig K von Segesser
Department of Cardio Vascular Surgery, Centre Hospitalier Universitaire Vaudois, CHUV, Lausanne, Lausanne, Switzerland
Interact Cardiovasc Thorac Surg 7:1096-100. 2008..Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB)...
Bovine valved xenograft in pulmonary position: medium-term follow-up with excellent hemodynamics and freedom from calcificationAntonio F Corno
Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
Ann Thorac Surg 78:1382-8; discussion 1382-8. 2004..This study was designed to evaluate the outcome of Contegra xenograft valved conduit (Contegra, Medtronic Inc, Minneapolis, MN)...
A novel technique using echocardiography to evaluate venous cannula performance perioperatively in CPB cardiac surgeryDavid Jegger
Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois CHUV, Rue du Bugnon 46, 1011 Lausanne, Switzerland
Eur J Cardiothorac Surg 29:525-9. 2006..Also, little progress has been made in venous cannula design in order to optimise venous return to the heart lung machine. We designed a self-expandable Smartcanula (SC) and analysed its performance capability using echocardiography...
Artificial muscles to restore transport function of diseased atriaPiergiorgio Tozzi
Cardiovascular Surgery Department, CHUV, Lausanne
ASAIO J 54:11-3. 2008..Preload ranged from 15 to 21 cm H20. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml/min. This artificial muscle pump is compact, and reproduces the hemodynamic performances of normal atrium...
[Preoperative assessment in emergency cardiovascular surgery]Ludwig K von Segesser
Service de Chirurgie Cardio vasculaire, CHUV, Lausanne
Rev Med Suisse Romande 124:395-9. 2004..However, hemodynamic instability and other time related events correlated with negative outcome, are the main driving forces for accelerated diagnostic pathways..
Aortic valve lesion after coronary angiographyTanina Rolf
Department of Cardiovascular Surgery, Lausanne University Hospital, Rue du Bugnon 46, 1011 Lausanne, Switzerland
Interact Cardiovasc Thorac Surg 12:205-6. 2011..Seven days later the echocardiography showed acute severe aortic valve insufficiency. Intraoperatively we found a perforated leaflet probably due to lesion during transcatheter procedure...
Do valved stents compromise coronary flow?Christoph H Huber
Service de chirurgie cardiovasculaire, Centre Hospitalier Universitaire Vaudois CHUV, 1011 Lausanne, Switzerland
Eur J Cardiothorac Surg 25:754-9. 2004..The aim of the present study is to evaluate a new self-expanding valved stent design for minimal invasive aortic valve implantation and its interference with coronary flow...
Primary isolated aortic valve surgery in octogenariansEnrico Ferrari
Department of Cardiovascular Surgery, University Hospital of Lausanne CHUV, 46 Rue du Bugnon, CH 1011, Lausanne, Switzerland
Eur J Cardiothorac Surg 38:128-33. 2010..We reviewed our surgery registry, to identify predictive risk factors for operative results, and to analyse the long-term survival outcome in octogenarians operated for primary isolated aortic valve replacement (AVR)...
Totally implantable robot to treat chronic atrial fibrillationPiergiorgio Tozzi
Cardiovascular Surgery Department, CHUV, Lausanne, Switzerland
Bioinspir Biomim 3:035009. 2008..This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation...
An IVUS-based approach to traumatic aortic rupture, with a look at the lesion from insideBettina Marty
Department of Cardiovascular Surgery, University Hospital, Lausanne, Switzerland
J Endovasc Ther 14:689-97. 2007....
Superior flow for bridge to life with self-expanding venous cannulasLudwig K von Segesser
Department of Cardio Vascular Surgery, CardioMet, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
Eur J Cardiothorac Surg 36:665-9. 2009....
Artificial muscle to wash blood out of fibrillating atrium: an alternative to lifelong anticoagulationPiergiorgio Tozzi
Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
ASAIO J 55:24-7. 2009..Possible clinical implications in patients with chronic AF are prevention of embolism of cardiac origin and avoidance of hemorrhagic complication due to chronic anticoagulation...
Myocardial and pulmonary effects of aqueous oxygen with acute hypoxiaAntonio F Corno
Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudo, Lausanne, Switzerland
Ann Thorac Surg 78:956-60; discussion 956-60. 2004..The purpose of this paper was to evaluate myocardial and pulmonary effects of aqueous oxygen (AO) delivered directly into the pulmonary circulation in acute hypoxia...
Biometal muscle to restore atrial transport function in a permanent atrial fibrillation animal model: a potential tool in the treatment of end-stage heart failurePiergiorgio Tozzi
Cardiovascular Surgery Department, CHUV, Lausanne, Switzerland
Eur J Cardiothorac Surg 37:870-4. 2010..This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model...
The Smartcanula: a new tool for remote access perfusion in limited access cardiac surgeryLudwig K von Segesser
Department of Cardio Vascular Surgery, Centre Hospitalier Universitaire Vaudois, CHUV, Lausanne, Switzerland
Heart Surg Forum 8:E241-5. 2005..The benefits of smart cannulation are obvious in remote cannulation for limited access cardiac surgery, but there are many other cannula applications where space is an issue, and that is where smart cannulation is most effective...
Endovascular surgery for failed open aortic aneurysm repairLudwig K von Segesser
Department of Cardio Vascular Surgery, Centre Hospitalier Universitaire Vaudois, CHUV, Rue du Bugnon 46, CH 1011 Lausanne, Switzerland
Eur J Cardiothorac Surg 26:614-20. 2004..Determine the usefulness of endovascular surgery for repair of aortic lesions late after open surgical repair...
Pulmonary artery banding: long-term telemetric adjustmentAntonio F Corno
Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, 46 Rue du Bugnon, CH 1011, Lausanne, Switzerland
Eur J Cardiothorac Surg 23:317-22. 2003..A., Lausanne, Switzerland) allowing for progressive occlusion/reopening of the device through a remote control at the wanted percentage of occlusion (adjustable pulmonary artery banding) underwent experimental evaluation...
The Vascular Join: a new sutureless anastomotic device to perform end-to-end anastomosis. Preliminary results in an animal modelEnrico Ferrari
Department of Cardiovascular Surgery, Centre Hopitalier Universitaire Vaudois, Lausanne, Switzerland
Interact Cardiovasc Thorac Surg 6:5-8. 2007..Further animal studies are underway to assess the long-term results. Following the same technical criteria, we are developing an end-to-side anastomotic device...
A novel device for reducing hemolysis provoked by cardiotomy suction during open heart cardiopulmonary bypass surgery: a randomized prospective studyDavid Jegger
Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
Artif Organs 31:23-30. 2007..05). This novel SS device evokes significantly lowered blood PFH and LDH values peri- and post CPB compared with the CTRL blood using a CS system. The SS may be a valuable alternative compared to traditional CS techniques...
Successful transapical aortic valve implantation in a congenital bicuspid aortic valveEnrico Ferrari
Department of Cardio Vascular Surgery, University Hospital of Lausanne CHUV, Lausanne, Switzerland
Ann Thorac Surg 90:630-2. 2010..Postoperative distortion, malfunctioning, and paravalvular leaks were not detected...
Endovascular repair of aortic arch aneurysm after achievement of local anesthesiaGiuseppe Siniscalchi
Cardiovascular Surgery Department, , Lausanne, Switzerland
J Thorac Cardiovasc Surg 133:262-3. 2007
Adequate left ventricular preparation allows for arterial switch despite late referralAntonio E Corno
Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
Cardiol Young 13:49-52. 2003....
Hypoxia: unique myocardial morphology?Antonio F Corno
Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
J Thorac Cardiovasc Surg 127:1301-8. 2004..The objective of this study was to investigate the effects of chronic and intermittent hypoxia on myocardial morphology...
Ultimate test bench for pediatric biventricular assist device based on artificial musclesMirza Muradbegovic
Department of Cardiovascular Surgery, Centre Hospitalier Univesitaire Vaud CHUV, Lausanne, Switzerland
ASAIO J 57:62-7. 2011..The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data...
Myxoma on a mechanical mitral valve annulusTanina Rolf
Department of Cardiovascular Surgery, University Hospital of Lausanne CHUV, Lausanne, Switzerland
J Heart Valve Dis 20:599-600. 2011..The tumor was successfully treated by surgical excision, and a diagnosis of myxoma was confirmed both clinically and pathologically...
Endovascular thoracic aortic aneurysm repair without angiographyPiergiorgio Tozzi
From the CardioVascular Surgery Department, Centre Hospitalier Universitaire Vaudois CHUV, Lausanne, Switzerland
Innovations (Phila) 4:32-5. 2009..We have used it as an alternative to angiography in the endovascular thoracic aneurysm repair work-up...
Impact of endoluminal stenting for aortic surgeryLudwig K von Segesser
Department of Cardio Vascular Surgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
Eur J Cardiothorac Surg 26:S14-7; discussion S17-8. 2004..Special interest in this field (clinical and/or experimental) can enhance recruitment of patients. The opposite is also true.....
Accordion-like prosthesis for modified Blalock-Taussig shuntAntonio F Corno
Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
Asian Cardiovasc Thorac Ann 11:229-32. 2003..The use of this prosthesis is justified for reducing early and late complications potentially associated with the modified Blalock-Taussig shunt, particularly distortion of the pulmonary arteries...
Surgical glues: are they really adhesive?Bertrand R M Perrin
Department of Cardio Vascular Surgery, CHUV, Rue du Bugnon 46, 1011 Lausanne, Switzerland
Eur J Cardiothorac Surg 36:967-72. 2009..An industrial test, the bulge-and-blister test, which is very convenient for measuring adhesion energy, is applied to the surgical field to quantify adhesion of bioadhesives...
Transapical aortic valve implantation without angiography: proof of conceptEnrico Ferrari
Department of Cardiovascular Surgery, University Hospital of Lausanne Centre Hôpitalier Universitaire Vaudois, Lausanne, Switzerland
Ann Thorac Surg 89:1925-32. 2010..The transapical aortic valve implantation without angiography can prevent contrast-related complications...
Surgically induced unilateral pulmonary hypertension: time-related analysis of a new experimental modelAntonio F Corno
Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
Eur J Cardiothorac Surg 23:513-7. 2003..This study evaluated an experimental model of surgically induced unilateral pulmonary hypertension...
Ebstein's anomaly: one and a half ventricular repairAntonio F Corno
Cardiovascular Surgery, Centre Hospitalier Universitaire Vandois, Lausanne
Swiss Med Wkly 132:485-8. 2002....
Artificial muscle for end-stage heart failurePiergiorgio Tozzi
Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
ASAIO J 58:103-8. 2012..The device required a power supply of 6 V, 250 mA. This could be the beginning of an era in which BMs integrate or replace the mechanical function of natural muscles...
Management of pulmonary embolism during acrylic vertebroplastyPiergiorgio Tozzi
Department of Cardiovascular Surgery, Centre Hĵspitalier Universitaire Vaudois CHUV, Lausanne, Switzerland
Ann Thorac Surg 74:1706-8. 2002..The patient quickly recovered from respiratory and cardiac failure. We believe pulmonary embolectomy is a reliable and effective procedure to treat this rare and dreadful complication of acrylic vertebroplasty...
Intravascular ultrasound: potential tool to assess coronary anastomosis qualityPiergiorgio Tozzi
Department of Cardiovascular Surgery BH10, Centre Hospitalier Universitaire Vaudois, Rue du Bugnon 46, 1011 Lausanne, Switzerland
Asian Cardiovasc Thorac Ann 11:143-6. 2003..Coronary intravascular ultrasound can visualize intima-to-intima apposition and provide reliable calculations of anastomosis compliance...
Spontaneous coronary artery dissection in a young woman: from emergency coronary artery bypass grafting to heart transplantationEnrico Ferrari
Department of Cardiovascular Surgery, Centre Hôpitalier Universitaire Vaudois CHUV, 46 Rue du Bugnon, CH 1011 Lausanne, Switzerland
Eur J Cardiothorac Surg 28:349-51. 2005..The following hospital course was uncomplicated. To our knowledge, this is the second case of SCAD treated successfully by LVAD and orthotopic heart transplantation reported in literature...
Miniaturization in cardiopulmonary bypassLudwig K von Segesser
Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, CHUV, Lausanne, Switzerland
Perfusion 18:219-24. 2003..This report provides an update of already commercially available low prime perfusion devices (e.g., the CORx integrated pump-oxygenator) as well as promising prototypes like the smart suction system and the smartcanula...
Atria assist device to restore transport function of fibrillating atriumPiergiorgio Tozzi
Cardiovascular Surgery Department, CHUV, Lausanne, Switzerland
Eur J Cardiothorac Surg 33:263-7. 2008..A bench model reproducing the mechanical function of human atrium and human environment has been developed to assess the circulatory support that such a pump can provide...
[Preoperative assessment of peripheral arteriopathy]Piergiorgio Tozzi
Service de chirurgie cardiovasculaire, CHUV, Lausanne
Rev Med Suisse Romande 124:383-5. 2004
Acute myocardial infarction caused by coronary embolization of a papillary fibroelastoma of the thoracic ascending aortaTanina Rolf
Department of Cardiovascular Surgery, Lausanne University Hospital, Rue du Bugnon 46, 1011 Lausanne, Switzerland
Interact Cardiovasc Thorac Surg 11:676-7. 2010..Nowadays, surgical excision of PFE remains, the treatment of choice for symptomatic patients with excellent short- and long-term results but recurrence of PFE following surgical excision has not been reported...
Partial inflow occlusion facilitates accurate deployment of thoracic aortic endograftsBettina Marty
Department of Cardiovascular Surgery, University Hospital, Rue du Bugnon 46, 1011 Lausanne, Switzerland
J Endovasc Ther 11:175-9. 2004..To present a maneuver consisting of temporary blockage of the venous return to the heart for accurate deployment of thoracic aortic endoprostheses...
The transventricular-transseptal access to the aortic root: a new route for extrapleural trans-catheter aortic stent-valve implantationLigang Liu
Department of Cardio Vascular Surgery, University Hospital of Lausanne CHUV, Rue du Bugnon 46, CH 1011 Lausanne, Switzerland
Eur J Cardiothorac Surg 39:635-41. 2011..The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural trans-catheter aortic valved stent implantation via a subxyphoidian access...
Chronic hypoxia: a model for cyanotic congenital heart defectsAntonio F Corno
Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
J Thorac Cardiovasc Surg 124:105-12. 2002..A possible reason is reoxygenation injury at the beginning of cardiopulmonary bypass. In this study we tested the hypothesis that reoxygenation of chronically hypoxic hearts is worse than that of normoxic hearts...
Bovine jugular vein as right ventricle-to-pulmonary artery valved conduitAntonio F Corno
Centre Hospitalier Universitaire Vaudois (CHUV, Lausanne, Switzerland
J Heart Valve Dis 11:242-7; discussion 248. 2002....
Sutureless coronary anastomoses: revival of old conceptsPiergiorgio Tozzi
Department of Cardio Vascular Surgery, Centre Hospitalier Universitaire Vaudois CHUV, CH Lausanne, Switzerland
Eur J Cardiothorac Surg 22:565-70. 2002..The evidence of long-term graft patency is fundamental for any anastomotic device to become widely acceptable...
Self-expandable valved stent of large size: off-bypass implantation in pulmonary positionJun Qing Zhou
Cardiothoracic Department, The No. 1 People's Hospital of Shaoxing, Zhejiang, China
Eur J Cardiothorac Surg 24:212-6. 2003....
Double-crowned valved stents for off-pump mitral valve replacementLiang Ma
Cardiothoracic Department, The 1st Affiliated Hospital of Medical College, Zhejiang University, Hangzhou, China
Eur J Cardiothorac Surg 28:194-8; discussion 198-9. 2005..CONCLUSIONS: Off-pump implantation of a self-expandable valved stent in the mitral position is technically feasible. Further studies will assess if this procedure is also feasible in humans...
