Publications

  1. ncbi Research and development of a new RF-assisted device for bloodless rapid transection of the liver: computational modeling and in vivo experiments
    Fernando Burdio
    Department of Surgery, Hospital del Mar, Barcelona, Spain
    Biomed Eng Online 8:6. 2009
  2. ncbi RF tumor ablation with internally cooled electrodes and saline infusion: what is the optimal location of the saline infusion?
    Fernando Burdio
    Department of Surgery, Hospital del Mar, Barcelona, Spain
    Biomed Eng Online 6:30. 2007
  3. ncbi Improved perfusion system for bipolar radiofrequency ablation of liver: preliminary findings from a computer modeling study
    Enrique J Berjano
    Center for Research and Innovation on Bioengineering, Valencia Polytechnic University, Valencia, Spain
    Physiol Meas 27:N55-66. 2006
  4. ncbi Theoretical modeling for radiofrequency ablation: state-of-the-art and challenges for the future
    Enrique J Berjano
    Center for Research and Innovation on Bioengineering, Valencia Polytechnic University, Camino de Vera s n, 46022 Valencia, Spain
    Biomed Eng Online 5:24. 2006
  5. ncbi What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysis
    Enrique J Berjano
    Center for Research and Innovation on Bioengineering, Valencia Polytechnic University, Camino de Vera s n, Spain
    Physiol Meas 26:837-48. 2005
  6. ncbi Modeling for radio-frequency conductive keratoplasty: implications for the maximum temperature reached in the cornea
    Enrique J Berjano
    Center for Research and Innovation on Bioengineering, Valencia Polytechnic University, Camino de Vera s n, 46022 Valencia, Spain
    Physiol Meas 26:157-72. 2005
  7. ncbi Radio-frequency heating of the cornea: theoretical model and in vitro experiments
    Enrique J Berjano
    Departamento de Ingenieria Electronica, Universidad Politecnica de Valencia, Spain
    IEEE Trans Biomed Eng 49:196-205. 2002
  8. ncbi Long electrodes for radio frequency ablation: comparative study of surface versus intramural application
    Enrique J Berjano
    Departamento de Ingenieria Electronica, Universidad Politecnica de Valencia, Camino de Vera s n, 46022 Valencia, Spain
    Med Eng Phys 25:869-77. 2003
  9. ncbi Ring electrode for radio-frequency heating of the cornea: modelling and in vitro experiments
    E J Berjano
    Electronic Engineering Department, Valencia Polytechnic University, Valencia, Spain
    Med Biol Eng Comput 41:630-9. 2003
  10. ncbi Thermal-electrical modeling for epicardial atrial radiofrequency ablation
    Enrique J Berjano
    Departamento de Ingenieria Electronica, Universidad Politécnica de Valencia Camino de Vera s n, Valencia, Spain
    IEEE Trans Biomed Eng 51:1348-57. 2004

Collaborators

  • Jorge Alio
  • Javier Saiz
  • Felipe Atienza
  • Fernando Burdio
  • Fernando Hornero Sos
  • Fernando Hornero
  • Juan L Lequerica
  • Jesus Herreros
  • Juan A Lopez Molina
  • Maria Herrero
  • Ana C Navarro
  • Ignacio Rodriguez
  • Maria J Rivera
  • Lemuel Melecio
  • Irene Calvo
  • Macarena Trujillo
  • Laura Sales-Nebot
  • Pedro Mas
  • Salvador Mercé
  • Stefano Mastrobuoni
  • Antonio Guemes
  • Miguel A De Gregorio
  • José M Burdío
  • Eloy Tejero
  • Ricardo Lozano
  • Ramon Sousa

Detail Information

Publications21

  1. ncbi Research and development of a new RF-assisted device for bloodless rapid transection of the liver: computational modeling and in vivo experiments
    Fernando Burdio
    Department of Surgery, Hospital del Mar, Barcelona, Spain
    Biomed Eng Online 8:6. 2009
    ..In this paper we present our broad research plan for a new RF-assisted device for bloodless, rapid resection of the liver...
  2. ncbi RF tumor ablation with internally cooled electrodes and saline infusion: what is the optimal location of the saline infusion?
    Fernando Burdio
    Department of Surgery, Hospital del Mar, Barcelona, Spain
    Biomed Eng Online 6:30. 2007
    ..However, the effect of infusion at a distance from the electrode surface is unknown. Our aim was to assess the effect of perfusion distance (PD) on the coagulation geometry and deposited power during RFA using ICE...
  3. ncbi Improved perfusion system for bipolar radiofrequency ablation of liver: preliminary findings from a computer modeling study
    Enrique J Berjano
    Center for Research and Innovation on Bioengineering, Valencia Polytechnic University, Valencia, Spain
    Physiol Meas 27:N55-66. 2006
    ..Future experimental studies should confirm this benefit...
  4. ncbi Theoretical modeling for radiofrequency ablation: state-of-the-art and challenges for the future
    Enrique J Berjano
    Center for Research and Innovation on Bioengineering, Valencia Polytechnic University, Camino de Vera s n, 46022 Valencia, Spain
    Biomed Eng Online 5:24. 2006
    ..After analyzing the current and future benefits of this technique it finally suggests future lines and trends in the research of this area...
  5. ncbi What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysis
    Enrique J Berjano
    Center for Research and Innovation on Bioengineering, Valencia Polytechnic University, Camino de Vera s n, Spain
    Physiol Meas 26:837-48. 2005
    ..In conclusion, this theoretical model allows us to study the effect of different factors on the thermal injury in the esophagus during intraoperative radiofrequency ablation of atrial tissue...
  6. ncbi Modeling for radio-frequency conductive keratoplasty: implications for the maximum temperature reached in the cornea
    Enrique J Berjano
    Center for Research and Innovation on Bioengineering, Valencia Polytechnic University, Camino de Vera s n, 46022 Valencia, Spain
    Physiol Meas 26:157-72. 2005
    ....
  7. ncbi Radio-frequency heating of the cornea: theoretical model and in vitro experiments
    Enrique J Berjano
    Departamento de Ingenieria Electronica, Universidad Politecnica de Valencia, Spain
    IEEE Trans Biomed Eng 49:196-205. 2002
    ..There is a tendency toward the agreement between experimental and theoretical results, although we have observed that the theoretical model overestimates the lesion dimension...
  8. ncbi Long electrodes for radio frequency ablation: comparative study of surface versus intramural application
    Enrique J Berjano
    Departamento de Ingenieria Electronica, Universidad Politecnica de Valencia, Camino de Vera s n, 46022 Valencia, Spain
    Med Eng Phys 25:869-77. 2003
    ..In conclusion, the results suggest that the IE might be a more suitable option than SAE when it is necessary to create long and homogeneous thermal lesions...
  9. ncbi Ring electrode for radio-frequency heating of the cornea: modelling and in vitro experiments
    E J Berjano
    Electronic Engineering Department, Valencia Polytechnic University, Valencia, Spain
    Med Biol Eng Comput 41:630-9. 2003
    ..The results suggest that the critical shrinkage temperature (55-63 degrees C) was reached at the central stroma and along the entire circular path in all the cases...
  10. ncbi Thermal-electrical modeling for epicardial atrial radiofrequency ablation
    Enrique J Berjano
    Departamento de Ingenieria Electronica, Universidad Politécnica de Valencia Camino de Vera s n, Valencia, Spain
    IEEE Trans Biomed Eng 51:1348-57. 2004
    ..It was also proved that the presence of a fat layer between the electrode and the atrial tissue decreased significantly the lesion dimensions...
  11. ncbi Effect of the thermal wave in radiofrequency ablation modeling: an analytical study
    Juan A Lopez Molina
    Applied Mathematics Department, Instituto de Matemática Pura y Aplicada, Valencia Polytechnic University, Valencia, Spain
    Phys Med Biol 53:1447-62. 2008
    ....
  12. ncbi A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom
    Juan L Lequerica
    Cardiac Research Laboratory, Instituto de Biomedicina, Spanish Council for Scientific Research CSIC, Valencia, Spain
    Phys Med Biol 53:N25-34. 2008
    ..The study suggests that the cooling balloon gives thermal protection to the esophagus when a minimum pre-cooling period of 2 min is programmed at a coolant temperature of 5 degrees C or less...
  13. ncbi Small ablation zones created previous to saline infusion result in enlargement of the coagulated area during perfusion RF ablation: an ex vivo experimental study
    Ana C Navarro
    Department of Surgery A, Hospital Clinico Universitario Lozano Blesa, Zaragoza, Spain
    Physiol Meas 28:N29-37. 2007
    ..These results suggest that the creation of small ablation zones prior to saline infusion improves the performance of this perfusion system, and hence the total volume...
  14. ncbi Gold-tip electrodes--a new 'deep lesion' technology for catheter ablation? In vitro comparison of gold alloy versus platinum-iridium tip electrode ablation catheter
    Enrique J Berjano
    J Cardiovasc Electrophysiol 16:1395-6. 2005
  15. ncbi Esophageal temperature monitoring during radiofrequency catheter ablation: experimental study based on an agar phantom model
    Ignacio Rodriguez
    Department of Cardiac Surgery, University General Hospital, Valencia, Spain
    Physiol Meas 28:453-63. 2007
    ..This fact can be explained by the distance gap between the thermocouple and probe and by the dynamic response of the ETP. The longer the distance between the ETP and catheter axis, the higher is the temperature difference...
  16. ncbi A cooled intraesophageal balloon to prevent thermal injury during endocardial surgical radiofrequency ablation of the left atrium: a finite element study
    Enrique J Berjano
    Center for Research and Innovation on Bioengineering, Valencia Polytechnic University, Camino de Vera s n, 46022 Valencia
    Phys Med Biol 50:N269-79. 2005
    ..Finally, the results also suggest that the use of a cooled balloon could affect the transmurality of the atrial lesion, especially in the cases where the atrium is of considerable thickness...
  17. ncbi Atrial ablation and esophageal injury: comments on an experimental study
    Fernando Hornero
    J Thorac Cardiovasc Surg 132:212-3; author reply 213-4. 2006
  18. ncbi Esophageal temperature during radiofrequency-catheter ablation of left atrium: a three-dimensional computer modeling study
    Fernando Hornero
    Cardiac Surgery Department, Valencia University General Hospital, Spain
    J Cardiovasc Electrophysiol 17:405-10. 2006
    ....
  19. ncbi Intramural radiofrequency ablation: effects of electrode temperature and length
    Enrique J Berjano
    Pacing Clin Electrophysiol 28:79. 2005
  20. ncbi A new method of providing pulsatile flow in a centrifugal pump: assessment of pulsatility using a mock circulatory system
    Jesus Herreros
    Cardiovascular Surgery Department, Clinica Universitaria, University of Navarra, Pamplona, Spain
    Artif Organs 32:490-4. 2008
    ..The pulsatility of the new pump was approximately 25% of that created with a truly pulsatile pump...