[Dislocated fracture of the lesser trochanter with malrotation of the stem after robot assisted implantation of a cementless hip prosthesis: a casuistic report]M Prymka
Orthopadische Universitatsklinik, Christian Albrechts Universitat Kiel, Germany
Unfallchirurg 106:671-5. 2003
..A revision operation was necessary,where we implanted a cemented stem. Now clinical progress was completely satisfying...
[Extravertebral cement drainage with occlusion of the extradural venous plexus into the vena cava after vertebrobplasty. Case report and review of the literature]M Prymka
Orthopadische Klinik, Universitatsklinikum Schleswig Holstein, Campus Kiel, Kiel
Unfallchirurg 106:860-4. 2003
..We prescribed a lumbar brace as external stabilisation and as an antithrombotic treatment we gave the patient weight adapted low molecular weight heparin...
[Primary rotatory stability of robot-assisted and manually implanted hip endoprosthesis stems]M Prymka
Orthopädische Klinik des Universitätsklinikums Schleswig Holstein, Campus Kiel
Unfallchirurg 107:285-93. 2004
..The CBC stem was most stable for rotatory forces after robot-assisted implantation compared to the other two types. After manual implantation there was no difference in stability between the different stems...
[Primary rotatory stability of hip endoprostheses stems after manual and robot assisted implantation]M Prymka
Orthopädische Klinik des Universitätsklinikums Schleswig Holstein, Campus Kiel
Z Orthop Ihre Grenzgeb 142:303-8. 2004
..In our study we compared the primary rotatory stability of hip endoprostheses which were implanted with the help of a robot with that of manually implanted stems...
The dimensional accuracy for preparation of the femoral cavity in HIP arthroplasty. A comparison between manual- and robot-assisted implantation of hip endoprosthesis stems in cadaver femursMarcel Prymka
Clinic for Orthopaedic Surgery, University Clinicum Schleswig Holstein, Campus Kiel, Michaelisstreet 1, 24105, Kiel, Germany
Arch Orthop Trauma Surg 126:36-44. 2006
..The aim of the study was to determine the precision of the preparation of the femoral cavity in cementless hip arthroplasty. We compared the bone-prosthesis interface after manual- and robot-assisted implantation of the stems...
[Modified percutaneous balloon kyphoplasty at osteolysis of 11th thoracic vertebra and communication with the spinal canal. Case report and review of the literature]M Prymka
Orthopadische Klinik, Universitat, Michaelisstrasse 1, 24105, Kiel, Germany
Orthopade 35:659-64. 2006
..With this technique we achieved an optimal filling of the destroyed vertebral body with cement, without any leakage. Two days postoperatively, the patient could leave our hospital without any pain symptoms...
[Clinical outcome, 6 years after robot assisted hip endoprostheses implantation--a prospective study]M Prymka
Orthopädische Klinik des Universitätsklinikums Schleswig Holstein, Campus Kiel
Z Orthop Unfall 147:675-82. 2009
..In our prospective study we evaluated the clinical and radiological results of 36 patients who had a robot-assisted implantation of a cementless hip endoprosthesis...
[Mechanisms and prevention of kitesurfing injuries]W Petersen
Klinik für Orthopädie der CAU Kiel, Germany
Sportverletz Sportschaden 16:115-21. 2002
..Kitesurfing is a new rapidly growing sport. To date the risk potential of this new sport is unclear. The analysis of the injury mechanisms allows conclusion regarding the prevention of kitesurfing injuries...