H Brodoefel

Summary

Country: Germany

Publications

  1. ncbi Accuracy of automated attenuation-based 3-dimensional segmentation: in the analysis of left ventricular function compared with magnetic resonance imaging
    Harald Brodoefel
    Department of Diagnostic Radiology, Division of Sports Medicine, Eberhard Karls University, 72076 Tubingen, Germany
    Tex Heart Inst J 39:36-43. 2012
  2. ncbi Herpes-Simplex-Virus 1 pneumonia in the immunocompromised host: high-resolution CT patterns in correlation to outcome and follow-up
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tuebingen, Germany
    Eur J Radiol 81:e415-20. 2012
  3. ncbi Noninvasive coronary angiography using 64-slice spiral computed tomography in an unselected patient collective: effect of heart rate, heart rate variability and coronary calcifications on image quality and diagnostic accuracy
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    Eur J Radiol 66:134-41. 2008
  4. ncbi Dual-source CT with improved temporal resolution in assessment of left ventricular function: a pilot study
    Harald Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    AJR Am J Roentgenol 189:1064-70. 2007
  5. ncbi Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy
    Harald Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    Radiology 247:346-55. 2008
  6. ncbi Sixty-four-MSCT in the characterization of porcine acute and subacute myocardial infarction: determination of transmurality in comparison to magnetic resonance imaging and histopathology
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    Eur J Radiol 62:235-46. 2007
  7. ncbi Cardiac dual-source computed tomography: effect of body mass index on image quality and diagnostic accuracy
    Harald Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Tubingen, Germany
    Invest Radiol 43:712-8. 2008
  8. ncbi Early and late-onset acute GvHD following hematopoietic cell transplantation: CT features of gastrointestinal involvement with clinical and pathological correlation
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, 72076 Tubingen, Germany
    Eur J Radiol 73:594-600. 2010
  9. ncbi Accuracy of dual-source CT in the characterisation of non-calcified plaque: use of a colour-coded analysis compared with virtual histology intravascular ultrasound
    H Brodoefel
    Department of Radiology, Beth Israel Deaconess Medical Centre, Boston, MA, USA
    Br J Radiol 82:805-12. 2009
  10. ncbi Late myocardial enhancement assessed by 64-MSCT in reperfused porcine myocardial infarction: diagnostic accuracy of low-dose CT protocols in comparison with magnetic resonance imaging
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    Eur Radiol 17:475-83. 2007

Detail Information

Publications36

  1. ncbi Accuracy of automated attenuation-based 3-dimensional segmentation: in the analysis of left ventricular function compared with magnetic resonance imaging
    Harald Brodoefel
    Department of Diagnostic Radiology, Division of Sports Medicine, Eberhard Karls University, 72076 Tubingen, Germany
    Tex Heart Inst J 39:36-43. 2012
    ..Hence this method should be used with caution, and its time benefits should be weighed against its imprecision of functional analysis...
  2. ncbi Herpes-Simplex-Virus 1 pneumonia in the immunocompromised host: high-resolution CT patterns in correlation to outcome and follow-up
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tuebingen, Germany
    Eur J Radiol 81:e415-20. 2012
    ..To identify the high-resolution CT (HRCT) patterns of Herpes-Simplex-Virus 1 (HSV) pneumonia in immunocompromised patients and correlate findings to outcome and radiographic follow-up until death or complete resolution of findings...
  3. ncbi Noninvasive coronary angiography using 64-slice spiral computed tomography in an unselected patient collective: effect of heart rate, heart rate variability and coronary calcifications on image quality and diagnostic accuracy
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    Eur J Radiol 66:134-41. 2008
    ..The aim of this study was to assess the impact of heart rate, heart rate variability and calcification on image quality and diagnostic accuracy in an unselected patient collective...
  4. ncbi Dual-source CT with improved temporal resolution in assessment of left ventricular function: a pilot study
    Harald Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    AJR Am J Roentgenol 189:1064-70. 2007
    ....
  5. ncbi Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy
    Harald Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    Radiology 247:346-55. 2008
    ....
  6. ncbi Sixty-four-MSCT in the characterization of porcine acute and subacute myocardial infarction: determination of transmurality in comparison to magnetic resonance imaging and histopathology
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    Eur J Radiol 62:235-46. 2007
    ....
  7. ncbi Cardiac dual-source computed tomography: effect of body mass index on image quality and diagnostic accuracy
    Harald Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Tubingen, Germany
    Invest Radiol 43:712-8. 2008
    ..The aim of our study was to assess the impact of body mass index (BMI) on image quality and diagnostic accuracy using dual-source computed tomography...
  8. ncbi Early and late-onset acute GvHD following hematopoietic cell transplantation: CT features of gastrointestinal involvement with clinical and pathological correlation
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, 72076 Tubingen, Germany
    Eur J Radiol 73:594-600. 2010
    ..The aim of this study was to describe and compare CT features of gastrointestinal early and late-onset GvHD and to correlate findings with clinical and pathology grading...
  9. ncbi Accuracy of dual-source CT in the characterisation of non-calcified plaque: use of a colour-coded analysis compared with virtual histology intravascular ultrasound
    H Brodoefel
    Department of Radiology, Beth Israel Deaconess Medical Centre, Boston, MA, USA
    Br J Radiol 82:805-12. 2009
    ..99, respectively. We found that using Hounsfield unit-based analysis, DSCT allows for accurate quantification of non-calcified plaque. Although percentage plaque composition proves highly reproducible, it is not correlated with IVUS-VH...
  10. ncbi Late myocardial enhancement assessed by 64-MSCT in reperfused porcine myocardial infarction: diagnostic accuracy of low-dose CT protocols in comparison with magnetic resonance imaging
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    Eur Radiol 17:475-83. 2007
    ..Myocardial viability can accurately be assessed by MSCT at 80 kV, which ensures higher contrast for late enhancement and yields good correlation with MRI...
  11. ncbi Sixty-four-slice CT in the assessment of global and regional left ventricular function: comparison with MRI in a porcine model of acute and subacute myocardial infarction
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076, Tubingen, Germany
    Eur Radiol 17:2948-56. 2007
    ..Sixty-four-slice CT allows for reliable analysis of global cardiac function and, moreover, provides accurate evaluation of wall motion in acute and subacute myocardial infarct...
  12. ncbi Non-invasive coronary angiography with 16-slice spiral computed tomography: image quality in patients with high heart rates
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karl University, Hoppe Seyler Str 3, 72076, Tubingen, Germany
    Eur Radiol 16:1434-41. 2006
    ..5 for the LM, 1.9 for the LAD, 2.0 for the CX and 2.3 for the RCA. At high heart rates, good image quality of the coronary arteries is achieved by 16-slice CT and a sophisticated reconstruction strategy at peak to late systole...
  13. ncbi Characterization of coronary atherosclerosis by dual-source computed tomography and HU-based color mapping: a pilot study
    H Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Tubingen, Germany
    Eur Radiol 18:2466-74. 2008
    ..90 for plaque volume and 0.81, 0.94 or 0.98 for percentages of fatty, fibrous or calcified components. With use of optimized HU thresholds, color mapping allows for accurate and reproducible quantification of coronary plaque...
  14. ncbi Cardiac CT in 2009
    C Burgstahler
    Department of Internal Medicine, Division of Sports Medicine, Eberhard Karls University, Tuebingen, Germany
    Minerva Cardioangiol 57:495-509. 2009
    ..This review focuses on present clinical indications and future application of multi-slice computed tomography in clinical cardiology...
  15. ncbi Automatic bone and plaque removal using dual energy CT for head and neck angiography: feasibility and initial performance evaluation
    C Thomas
    Department of Diagnostic and Interventional Radiology, University of Tubingen, Tubingen, Germany
    Eur J Radiol 76:61-7. 2010
    ..We sought to evaluate the feasibility and efficiency of dual energy (DE) bone and plaque removal in head and neck CT angiography...
  16. ncbi Disseminated mucormycosis in haematological patients: CT and MRI findings with pathological correlation
    M Horger
    Department of Diagnostic Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, , Germany
    Br J Radiol 79:e88-95. 2006
    ..Identification of one or both of these two major imaging findings in immunocompromised patients should be regarded as an indicator of possible infection by angiotropic fungi, including the genre Mucorales...
  17. ncbi Differences and similarities of cytomegalovirus and pneumocystis pneumonia in HIV-negative immunocompromised patients thin section CT morphology in the early phase of the disease
    M N Vogel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    Br J Radiol 80:516-23. 2007
    ..However, some features thought typical for one or the other entities appear with similar frequency in both groups in HIV-negative patients...
  18. ncbi Iterative Reconstruction in Head CT: Image Quality of Routine and Low-Dose Protocols in Comparison with Standard Filtered Back-Projection
    A Korn
    Departments of Diagnostic und Interventional Neuroradiology
    AJNR Am J Neuroradiol 33:218-24. 2012
    ..The purpose of our study was to assess the potential benefit of IR in head CT by comparing objective and subjective image quality with standard FBP at various dose levels...
  19. ncbi Dual-energy CT for the characterization of urinary calculi: In vitro and in vivo evaluation of a low-dose scanning protocol
    C Thomas
    Department of Diagnostic and Interventional Radiology, University of Tubingen, Tubingen, Germany
    Eur Radiol 19:1553-9. 2009
    ..In conclusion, dual-energy urinary calculus analysis is effective also with a low-dose protocol. The protocol tested in this study reliably identified calcified urinary calculi in vivo...
  20. ncbi Evaluation of cardiac function and myocardial viability with 16- and 64-slice multidetector computed tomography
    Andreas F Kopp
    Department of Diagnostic Radiology, Eberhard Karls University Tuebingen, Hoppe Seyler Str 3, 72076 Tuebingen, Germany
    Eur Radiol 15:D15-20. 2005
    ..CT late enhancement adds valuable diagnostic information on the haemodynamical significance of coronary stenoses or prior to interventional procedures...
  21. ncbi Long-term CT follow-up in 40 non-HIV immunocompromised patients with invasive pulmonary aspergillosis: kinetics of CT morphology and correlation with clinical findings and outcome
    Harald Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Strasse 3, 72076 Tuebingen, Germany
    AJR Am J Roentgenol 187:404-13. 2006
    ..The aim of this study was to assess CT signs of invasive pulmonary aspergillosis (IPA) and their long-term kinetics in correlation with clinical findings and outcome...
  22. ncbi Assessment of myocardial viability in a reperfused porcine model: evaluation of different MSCT contrast protocols in acute and subacute infarct stages in comparison with MRI
    Harald Brodoefel
    Department of Diagnostic Radiology, Eberhard Karls University, Tubingen, Germany
    J Comput Assist Tomogr 31:290-8. 2007
    ..To assess myocardial viability in acute and subacute infarcts using different multislice spiral computed tomography contrast protocols with magnetic resonance imaging (MRI) correlation...
  23. ncbi Advances in imaging protocols for cardiac MDCT: from 16- to 64-row multidetector computed tomography
    Andreas F Kopp
    Department of Diagnostic Radiology, Eberhard Karls, University Tuebingen, Hoppe Seyler Str 3, 72076 Tuebingen, Germany
    Eur Radiol 15:E71-7. 2005
    ..Beginning with 4-slice scanners in 1999, the latest scanner generation employs 64 slices. The present article summarizes the technical principles, image protocols and possible clinical applications of the current 64-row scanners...
  24. ncbi Dual-source computed tomography: advances of improved temporal resolution in coronary plaque imaging
    Anja J Reimann
    Department of Diagnostic Radiology, Eberhard Karls University of Tuebingen, Tuebingen, Germany
    Invest Radiol 42:196-203. 2007
    ....
  25. ncbi Coronary plaque quantification by voxel analysis: dual-source MDCT angiography versus intravascular sonography
    Harald Brodoefel
    Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Ave, WCC 302, Boston, MA 02215, USA
    AJR Am J Roentgenol 192:W84-9. 2009
    ..The purpose of this study was to evaluate a voxel-based analytic technique for quantification of noncalcified coronary artery plaque with intravascular sonography as a standard of reference...
  26. ncbi Diagnostic accuracy and image quality of cardiac dual-source computed tomography in patients with arrhythmia
    Ilias Tsiflikas
    Department of Diagnostic Radiology, University Hospital Tuebingen, and Department of Internal Medicine Sports Medicine, University of Tuebingen, Germany
    Int J Cardiol 143:79-85. 2010
    ..Thus, the aim of the present study was to evaluate the diagnostic accuracy of a new dual-source computed tomography (DSCT) scanner generation with 83 ms temporal resolution in patients without stable sinus rhythm...
  27. ncbi Influence of a lipid-lowering therapy on calcified and noncalcified coronary plaques monitored by multislice detector computed tomography: results of the New Age II Pilot Study
    Christof Burgstahler
    Department of Internal Medicine, Division of Cardiology, Eberhard Karls University, Tuebingen, Germany
    Invest Radiol 42:189-95. 2007
    ..We also sought to assess the effect after 1 year of a lipid-lowering therapy (LLT) using 20 mg of atorvastatin...
  28. ncbi Pathologic fractures in patients with multiple myeloma undergoing bisphosphonate therapy: incidence and correlation with course of disease
    Monika N Vogel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Strasse 3, 72076 Tubingen, Germany
    AJR Am J Roentgenol 193:656-61. 2009
    ....
  29. ncbi Standardisation of liver MDCT by tracking liver parenchyma enhancement to trigger imaging
    H Brodoefel
    Department of Radiology, Harvard Medical School, Beth Israel Deaconess Medical Center, 330 Brookline Ave, Boston, MA 02215, USA
    Eur Radiol 22:812-20. 2012
    ..To assess parenchymal bolus-triggering in terms of liver enhancement, lesion-to-liver conspicuity and inter-image variability across serial follow-up MDCTs...
  30. ncbi Dual-energy computed tomography: is there a penalty in image quality and radiation dose compared with single-energy computed tomography?
    Christoph Thomas
    Department of Diagnostic and Interventional Radiology, University of Tubingen, Tubingen, Germany
    J Comput Assist Tomogr 34:309-15. 2010
    ..To assess dose and image quality of dual-energy (DE) mixed images in comparison to single-energy (SE) images...
  31. ncbi Does clinical pretest probability influence image quality and diagnostic accuracy in dual-source coronary CT angiography?
    Christoph Thomas
    Department of Diagnostic and Interventional Radiology, University of Tubingen, Hoppe Seyler Strasse 3, 72076 Tubingen, Germany
    Acad Radiol 17:212-8. 2010
    ..To prospectively evaluate the influence of the clinical pretest probability assessed by the Morise score onto image quality and diagnostic accuracy in coronary dual-source computed tomography angiography (DSCTA)...
  32. ncbi Spontaneous thoracic air-leakage syndrome in patients following allogeneic hematopoietic stem cell transplantation: causes, CT-follow up and patient outcome
    Monika Vogel
    Department of Diagnostic Radiology, Eberhard Karls University, Hoppe Seyler Str 3, 72076 Tubingen, Germany
    Eur J Radiol 60:392-7. 2006
    ....
  33. ncbi Coronary CT angiography with dual source computed tomography in 170 patients
    Ilias Tsiflikas
    University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Hoppe Seyler Str 3, 72076 Tuebingen, Germany
    Eur J Radiol 74:161-5. 2010
    ..The aim of the present study was to evaluate the reproducibility of these results in a large, unselected and consecutive group of patients scheduled for invasive coronary angiography (ICA)...
  34. ncbi Usefulness of noninvasive cardiac imaging using dual-source computed tomography in an unselected population with high prevalence of coronary artery disease
    Martin Heuschmid
    Department of Diagnostic Radiology, University Hospital Tuebingen, Tuebingen, Germany
    Am J Cardiol 100:587-92. 2007
    ..However, overestimation of stenosis, especially in cases of calcifications, is still a limitation...
  35. ncbi Detection of plaque rupture using 64-slice multidetector row computed tomography
    Anja J Reimann
    Department of Diagnostic Radiology, Eberhard Karls University, Tuebingen, Germany
    Can J Cardiol 24:223-4. 2008
    ..Multidetector row computed tomography helped to correctly position the stent by identifying the exact location of the rupture along the long plaque formation...
  36. ncbi Omental and peritoneal involvement in systemic amyloidosis: CT with pathologic correlation
    Marius Horger
    Eberhard-Karls-University, Tuebingen, Germany 72076
    AJR Am J Roentgenol 186:1193-5. 2006