Thomas Baad-Hansen

Summary

Affiliation: University of Copenhagen
Country: Denmark

Publications

  1. ncbi Comparison of performance of conventional and minimally invasive surgery acetabular reamers
    Thomas Baad-Hansen
    Department of Orthopaedic Surgery, Aarhus University Hospital, Denmark
    Clin Orthop Relat Res 448:173-9. 2006
  2. ncbi High-precision measurements of cementless acetabular components using model-based RSA: an experimental study
    Thomas Baad-Hansen
    Department of Orthopaedic Surgery, Aarhus University Hospital, Denmark
    Acta Orthop 78:463-9. 2007
  3. ncbi Two-year migration results of the ReCap hip resurfacing system-a radiostereometric follow-up study of 23 hips
    Thomas Baad-Hansen
    Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus C, Denmark
    Int Orthop 35:497-502. 2011
  4. ncbi Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips
    Thomas Baad-Hansen
    Department of Orthopaedic Surgery, Aarhus University Hospital, Denmark
    Acta Orthop 82:155-60. 2011
  5. ncbi Excessive distal migration of fiber-mesh coated femoral stems
    Thomas Baad-Hansen
    Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
    Acta Orthop 82:308-14. 2011

Collaborators

Detail Information

Publications5

  1. ncbi Comparison of performance of conventional and minimally invasive surgery acetabular reamers
    Thomas Baad-Hansen
    Department of Orthopaedic Surgery, Aarhus University Hospital, Denmark
    Clin Orthop Relat Res 448:173-9. 2006
    ..LEVEL OF EVIDENCE: Therapeutic Study, Level II (prospective comparative study with no statistically significant difference). See the Guidelines for Authors for a complete description of levels of evidence...
  2. ncbi High-precision measurements of cementless acetabular components using model-based RSA: an experimental study
    Thomas Baad-Hansen
    Department of Orthopaedic Surgery, Aarhus University Hospital, Denmark
    Acta Orthop 78:463-9. 2007
    ..Within the last few years, new software systems have been developed to solve this problem. We compared the precision of 3 RSA systems in migration analysis of the acetabular component...
  3. ncbi Two-year migration results of the ReCap hip resurfacing system-a radiostereometric follow-up study of 23 hips
    Thomas Baad-Hansen
    Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus C, Denmark
    Int Orthop 35:497-502. 2011
    ..Maximum translation was seen along the transverse axis in the medial direction (0.13 mm). No statistically significant translation or rotation was seen at two-years follow-up, (t-test, p <0.05, translation or rotation)...
  4. ncbi Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips
    Thomas Baad-Hansen
    Department of Orthopaedic Surgery, Aarhus University Hospital, Denmark
    Acta Orthop 82:155-60. 2011
    ..In this randomized RSA trial, we compared a new acetabular cup with a surface made of tantalum trabecular metal and a cup with a titanium fiber-mesh surface...
  5. ncbi Excessive distal migration of fiber-mesh coated femoral stems
    Thomas Baad-Hansen
    Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
    Acta Orthop 82:308-14. 2011
    ....