Research Topics
Species | Florian WolfSummaryAffiliation: Medical University of Vienna Country: Austria Publications
| Collaborators
|
Detail Information
Publications
Endovascular management of lost or misplaced intravascular objects: experiences of 12 yearsFlorian Wolf
Department of Radiology, Medical University Vienna, Waehringer Guertel 18 20, A 1180, Vienna, Austria
Cardiovasc Intervent Radiol 31:563-8. 2008..In conclusion, endovascular retrieval of lost or misplaced intravascular objects is highly effective, with relatively few minor complications. On the basis of our findings, these techniques should be considered as the therapy of choice...
Coronary artery stent imaging with 128-slice dual-source CT using high-pitch spiral acquisition in a cardiac phantom: comparison with the sequential and low-pitch spiral modeFlorian Wolf
Department of Radiology, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Waehringer Guertel 18 20, 1090, Vienna, Austria
Eur Radiol 20:2084-91. 2010..To evaluate coronary stents in vitro using 128-slice-dual-source computed tomography (CT)...
In vitro imaging of coronary artery stents: are there differences between 16- and 64-slice CT scanners?Florian Wolf
Medical University of Vienna, Department of Radiology, Waehringer Guertel 18 20, A 1090 Vienna, Austria
Eur J Radiol 68:465-70. 2008..To compare the performance of 64-slice with 16-slice CT scanners for the in vitro evaluation of coronary artery stents...
Endovascular management performed percutaneously of isolated iliac artery aneurysmsFlorian Wolf
Medical University of Vienna, Clinical Department of Cardiovascular and Interventional Radiology, Waehringer Guertel 18 20, A 1090 Vienna, Austria
Eur J Radiol 65:491-7. 2008..To report about the endovascular treatment of isolated iliac artery aneurysms (IIAA) with stentgraft placement and transluminal or CT-guided embolization of the internal iliac artery or the combination of these methods...
Prospective evaluation of high-resolution MRI using gadofosveset for stent-graft planning: comparison with CT angiography in 30 patientsFlorian Wolf
Department of Radiology, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Austria
AJR Am J Roentgenol 197:1251-7. 2011..The purpose of our study was to compare high-resolution gadofosveset-enhanced MR angiography (MRA) with the reference standard CT angiography (CTA) in planning endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms...
Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: comparison of a manual and automated 3D volume segmentation methodFlorian Wolf
Department of Radiology, Medical University of Vienna, Vienna, Austria
Eur J Radiol 75:e141-6. 2010..The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT)...
Improved detection of in-stent restenosis by blood pool agent-enhanced, high-resolution, steady-state magnetic resonance angiographyChristina M Plank
Department of Radiology, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Vienna, Austria
Eur Radiol 21:2158-65. 2011..Intra-arterial digital subtraction angiography (DSA) served as the reference standard...
Evaluation of coronary stents with 64-MDCT: in vitro comparison of scanners from four vendorsFlorian Wolf
Division of Cardiovascular and Interventional Radiology, Department of Radiology, Medical University of Vienna, Waehringer Guertel 18 20, 1090 Vienna, Austria
AJR Am J Roentgenol 193:787-94. 2009..The purpose of this study was to compare 64-MDCT scanners from four vendors in the in vitro evaluation of coronary artery stents...
Multidetector CTA in the quantification of internal carotid artery stenosis: value of different reformation techniques and axial source images compared with selective carotid arteriographyStefan Puchner
Department of Radiology, Medical University of Vienna, Vienna General Hospital, Vienna, Austria
J Endovasc Ther 16:336-42. 2009..To evaluate the role of 4 different reformation techniques and axial images from multidetector computed tomographic angiography (MDCTA) versus selective carotid arteriography (SCA) in patients with internal carotid artery (ICA) stenosis...
Contrast material-enhanced, moving-table MR angiography versus digital subtraction angiography for surveillance of peripheral arterial bypass graftsChristian Loewe
Section of Angiography and Interventional Radiology, Department of Radiology, University of Vienna, Waehringer Guertel 18 20, A 1090 Vienna, Austria
J Vasc Interv Radiol 14:1129-37. 2003..To assess the accuracy of moving-table MR angiography (MRA) in the evaluation of peripheral bypass grafts...
Computed tomography angiography of the carotid arteries at low kV settings: a prospective randomised trial assessing radiation dose and diagnostic confidenceDietrich Beitzke
Division of Cardiovascular and Interventional Radiology, Medical University Vienna, Waehringer Guertel 18 20, 1090 Vienna, Austria
Eur Radiol 21:2434-44. 2011..To assess radiation dose and diagnostic image quality of a low-dose (80 kV) versus a standard-dose (120 kV) protocol for computed tomography angiography (CTA) of the supra-aortic arteries...
Perceptibility and quantification of in-stent stenosis with six peripheral arterial stent types in vitro: comparison of 16-MDCT angiography, 64-MDCT angiography, and MR angiographyMelanie B Schernthaner
Department of Cardiovascular and Interventional Radiology, Medical University Vienna, Waehringer Guertel 18 20, A 1090 Vienna, Austria
AJR Am J Roentgenol 194:1346-51. 2010..The purpose of this study was to evaluate and compare the perceptibility of 75% and 95% in-stent stenoses with CT angiography and MR angiography using six stent types in a phantom model...
Diagnosis of popliteal venous entrapment syndrome by magnetic resonance imaging using blood-pool contrast agentsDietrich Beitzke
Section of Cardiovascular and Interventional Radiology, Department of Radiology, Medical University of Vienna, A 1090, Vienna, Austria
Cardiovasc Intervent Radiol 34:S12-6. 2011..We present imaging findings in a case of symptomatic popliteal vein entrapment diagnosed by the use of blood pool contrast-enhanced MRI...
Arterial embolization of unresectable hepatocellular carcinoma with use of microspheres, lipiodol, and cyanoacrylateThomas Rand
Department of Angiography and Interventional Radiology, University of Vienna, Waehringer Guertel 18 20, 1090 Vienna, Austria
Cardiovasc Intervent Radiol 28:313-8. 2005..TAE with the use of microspheres and Lipiodol and cyanoacrylate for unresectable HCC is a feasible treatment modality. Bland embolization with the use of microspheres can be used in patients for whom chemoembolization is not desired...
Time course of markers of tissue repair after ablation of atrial fibrillation and their relation to left atrial structural changes and clinical ablation outcomeBernhard Richter
Department of Cardiology, Medical University of Vienna, Vienna, Austria
Int J Cardiol 152:231-6. 2011..We sought to prospectively assess the time course of biomarkers of tissue repair after ablation and to evaluate their association with clinical variables...
MDCT angiography for detection of pulmonary emboli: comparison between equi-iodine doses of iomeprol 400 mgI/mL and iodixanol 320 mgI/mLHerbert Langenberger
Department of Radiology, Vienna General Hospital, Medical University, Waehringer Guertel 18 20, A 1090 Vienna, Austria
Eur J Radiol 70:579-88. 2009..To compare iomeprol 400 and iodixanol 320 in pulmonary artery MDCTA in subjects with suspected pulmonary embolism...
Detection of high-grade stenoses with multislice computed tomography in heart transplant patientsPhilipp Pichler
Department of Internal Medicine II, Division of Cardiology, Medical University of Vienna, Vienna, Austria
J Heart Lung Transplant 27:310-6. 2008..We sought to determine whether multislice computed tomography (MSCT) permits the exclusion or progression of coronary artery disease in heart transplant patients...
Dual-time-point FDG-PET/CT for the detection of hepatic metastasesAlbert Dirisamer
Radiology, University Hospital Vienna, Vienna, Austria
Mol Imaging Biol 10:335-40. 2008....
Endovascular stent-graft repair of complicated penetrating atherosclerotic ulcers of the descending thoracic aortaMaria Schoder
Department of Angiography and Interventional Radiology, Vienna General Hospital, University of Vienna, Vienna, Austria
J Vasc Surg 36:720-6. 2002..To report our initial experience with endovascular stent-graft repair of complicated penetrating atherosclerotic ulcers as an alternative to surgery in patients with increased risk of perioperative morbidity and mortality...
Performance of integrated FDG-PET/contrast-enhanced CT in the staging and restaging of colorectal cancer: comparison with PET and enhanced CTAlbert Dirisamer
Department of Nuclear Medicine, St Vincent s Hospital, Seilerstaette 4, 4010 Linz, Austria
Eur J Radiol 73:324-8. 2010..Therefore we proved whether diagnostic PET/CT adds information over PET or contrast-enhanced CT alone for staging or restaging of patients with colorectal cancer...
Integrated contrast-enhanced diagnostic whole-body PET/CT as a first-line restaging modality in patients with suspected metastatic recurrence of breast cancerAlbert Dirisamer
Department of Nuclear Medicine, St Vincent s Hospital, Seilerstaette 4, 4010 Linz, Austria
Eur J Radiol 73:294-9. 2010....
Atrial function after ablation procedure in patients with chronic atrial fibrillation using steady-state free precession magnetic resonance imagingTatjana Fleck
Department of Cardiothoracic Surgery, Medical University of Vienna, Vienna, Austria
Ann Thorac Surg 84:1600-4. 2007..The purpose of this study was to evaluate the feasibility and reproducibility of steady-state free precession magnetic resonance imaging (SSFP MRI) for examination of atrial dimensions and function after ablation procedures...
Virtual non-contrast in second-generation, dual-energy computed tomography: reliability of attenuation valuesMichael Toepker
Department of Radiology, Medical University Vienna Vienna General Hospital, Vienna, Austria
Eur J Radiol 81:e398-405. 2012....
Brain natriuretic peptide correlates with the extent of atrial fibrillation-associated silent brain lesionsWolfgang Gartner
Medical University Vienna, Department of Medicine III, Austria
Clin Biochem 41:1434-9. 2008..Identification of plasma markers indicative for atrial fibrillation-associated silent brain lesions...
Acute cardiac disease in a young patient with Campylobacter jejuni infection: a case reportChristina Kratzer
Department of Internal Medicine I, Medical University of Vienna, Vienna, Austria
Wien Klin Wochenschr 122:315-9. 2010..A large number of different infectious causes have been identified as leading to myocarditis, with enteroviral infections being the most common reasons...
The effect of low-dose simvastatin in children with familial hypercholesterolaemia: a 1-year observationAlbert Dirisamer
Department of Paediatrics, University of Vienna, , 1090, Austria
Eur J Pediatr 162:421-5. 2003..CONCLUSION: our results showed that simvastatin seems to be an effective and safe medical therapy even in children and adolescents with familial hypercholesterolaemia...
Percutaneous saline-enhanced radiofrequency ablation of unresectable hepatic tumors: initial experience in 26 patientsJoachim Kettenbach
Department of Diagnostic Radiology, Division of Angiography and Interventional Radiology, University of Vienna Medical School, , Austria
AJR Am J Roentgenol 180:1537-45. 2003..A greater number of radiofrequency applications, general anesthesia, and increasing experience provide significantly better results...
Elective endovascular stent-graft repair of atherosclerotic thoracic aortic aneurysms: clinical results and midterm follow-upMaria Schoder
Department of Angiography and Interventional Radiology, University of Vienna Medical School, , A-1090 Vienna, Austria
AJR Am J Roentgenol 180:709-15. 2003..4 mL, p = 0.68). CONCLUSION: Endovascular treatment of atherosclerotic thoracic aortic aneurysms may result in a substantial reduction of the aneurysm sac in patients without endoleaks...
